Loading...
1317 S COURSON DR (2)City of Anaheim L BUILDING DIVISION INSPECTION RECORD SWIMMING POOL ADDRESS: 1317 S COURSON DR, ANAHEIM, CA 92804 OWNER: OBYRNE STACEY L PERMITM SWI2022-00081 DATE ISSUED: 07/19/2022 DESCRIPTION: New Pool/Spa: 354 sf. gunite pool, 58 sf. spa and DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has been signed. plumbing for fire pit. POST THIS CARD WITH THE APPROVED PLANS IN A CONSPICUOUS PLACE ON THE JOB SITE Inspection Code Date Inspector y1. Main Drain 504 2. Electric Bonding 506 3. Steel 508 4. Approval to Gunite 510^ DO NOT GUNITE POOUSPA until all the above Inspections have been signed. 5. BLD -Steel and Electric bonding (Rock Structures,Slides Etc) 508 DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has been signed. 6. Underground Electric 512 (/ 7. Gas Piping Test 514 8. P -Trap Receptor $16 9. Backflow 518 fd...G. 10. Deck, Deck Drains, Equipotential & Accessory Bondino 520 /d DO NOT POUR FLATWORK until all the above inspections have been signed. 11. Rough Electrical 522 12. FencinglDoor Alarms 524 13. Plaster approval 526 DO NOT PLASTER until all the above inspections have been signed. 14. Final Electric 1 528 Sub -Contractors List MUST be approved and pool cover on site PRIOR to Pool Final inspection request FINAL INSPECTION CODE DATE INSPECTOR 15. Rough Demo 527 16. Final 599 MISC. INSPECTIONS Date Inspector fbldjobcards Inspections 1.5: 1. All plumbing to be completed and the system pressurized to 35 lbs. with water or house pressure. 2. All metal within 5 feet of pool water, and all pool equipment, must be bonnded to pool reinforcing steel with 08 solid copper wire. Niche light shell, deck Inserts, etc. shall be bonded to pool rebar. 3. Pool equipment is not required to be set at this time. Inspections 8.10: 1. Underground electric inspected prior to baddilling. 2' Gas line test at 100 for 15 minutes with 150 gauge. 3. When polyethylene gas piping Is used, a certificate from a cerlifted installer and tracer wire shall be provided per CPC 1210.1.7.2 APPENDIX I. Inspections 11.13: 1. Rough electric inspection when all wiring is completed and ready prior to the plastering of pooyspa. Potting compound In place at plastic light niche. 2. Current Code requires that any pool, spa or water feature contacting water 18 inches or more in depth shall be enclosed by a barrier adequate to prevent entry of small children. The banter shall comply with Section 3109 of current CBC and CRC APPDENDIX V specifying the height of any fence provided as barrier to the pool 8- shall be 60' above grade on the outside of the fence. 3. Doors from a garage shall meet the requirements for a gate. Glass windows within 5' of pool water shall be tempered glass. 4. Prior to pre -plaster Inspection, streets, curbs and city sidewalks will be Inspected for any damage due to construction of pool or spas. S. Grading complete with positive drainage to street or public way. All exposed plastic pipe shall be painted to protect from sunlight Inspections 1416: 1. Gas and Electrical completely removed and 2x2 holes at bottom of pool andlor Isolated elements. 2. Pool badktilled: A.) with future build - self -compacting send 95% with recelpt B.) No future build - any fill. 3. After pod Is operating and in working condition with approved pool cover on site. INSPECTION REQUESTS Inspection requests made prior to 5:00 pm Monday - Friday will be scheduled on the following workday. To schedule your building inspection online, please go to https://aca.anaheim.neUCitizenAccess Inspection can normally be reached between 7:30.8:00 A.M. (714)7654153 + 0 To access your inspection timeframe: Please go to www.anaheim.netlbuilding after 7:30am on the day of your Inspection. Under Online Services, dick on the link -Inspection Timeframes' or call (714) 765.5153 + 0