2516 E OSHKOSH AVECity of Anaheim
BUILDING DIVISION
INSPECTION RECORD
10 SWIMMING POOL
ADDRESS:
2516 E OSHKOSH AVE, ANAHEIM, CA 92806
OWNER:
SALTZMAN JOHN 6 BECKY
PERMIT #:
SWI2016-00097
DATE ISSUED:
08/30/2016
DESCRIPTION:
Pool: 580 sq.ft to reinstate expired permit number
DO NOT GUNITE ROCK STRUCTURE
(water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has
been signed.
#14802 built in 1964.
POST THIS CARD WITH THE APPROVED PLANS
IN A CONSPICUOUS PLACE ON THE JOB SITE
spection Code Date Inspector
504
ding 506
508
PBLD-Steel
Gunite 510
DO NOT GUNITE POOUSPA
until all the above Inspections have been signed.
nd Electric bonding
(Rock Structures,Slides Etc)
508
DO NOT GUNITE ROCK STRUCTURE
(water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has
been signed.
6. Underground Electric _
512
7. Gas Piping Test
514
8. P -Trap Receptor
516
9. Backflow
518
10. Deck, Deck Drains,
Equipotential & Accessory
Bondina
520
DO NOT POUR FLATWORK
until all the above inspections have been signed.
11. Rough Electrical 522
12. Fencing/Door Alarms 524 G Z
13. Plaster approval 526
DO NOT PLASTER
until all the above inspections have been signed.
14. Final Electric 52g,Q(
Sub -Contractors List MUST be approved and pool cover on site
PRIOR to Pool Final Inspection request
FINAL INSPECTION CODE DATE INSPECTOR
15. Rough Demo 527
16. Final 599
MISC. INSPECTIONS Date Inspector
fbldjobcards
Insoacdons 14:
1. A l plumbing to be completed and the system pressurized to 35 lbs. with water
or house pressure.
2. AN metal within 5 feet of pool water, and a9 pool equipment, must be bonnded
to pool reinforcing steel with 08 solid copper wire. Niche light shag, deck Inserts,
etc. shall be bonded to pool rebar.
3. Pod equipment is not required to be set at this time.
Insoactlons 8.10:
1. Underground electric Inspected prior to backfilling.
2. Gas gne test at 100 for 15 minutes with 150 gauge.
3. When polyethylene gas ping is used, a certificate Tran a certifted Installer
and tracer wire shall be provided per CPC 1210.1.72 APPENDIX 1.
Inspections 1143:
1. Rough electric Inspection when all wiring Is completed and ready prior to the
plastering of poollsps. Polling compound in place at plastic light niche.
2. Current Code requires that any pod, ape or water feature
contacting water 18 inches or more in depth shall be enclosed by a barrier
adequate to prevent entry of small children. The barrier shag comply with
Section 3109 of cement CBC and CRC APPOENDIX V specifying the height of
any fence provided as barrier to the pod ti- shall be 60' above grade on the
outside of the fence.
3. Doors from a garage shag meet the requirements for a gets. Glass
windows within F of pool water shag be tempered glass.
4. Prior to pro -plaster Inspection, streets, curbs and city sidewalks will be
Inspected for any damage due to construction of pod or spas.
5. Grading complete with positive drainage to street or pubic way. All
exposed plastic pipe shag be painted to protect from sunlight.
Inspections 14.16:
1. Gas and Electrical completely removed and 2x2 holes at bottom of pod
and/or Isolated elements.
2. Pod backfilled:
A.) With future build - selkompacting sand 95% with receipt
B.) No Nhfe build - any ill.
3. After pool Is operating and In working condillon with approved pod cover on
site.
Inspection requests made prior to 5:00 pm Monday - Friday
will be scheduled on the following workday.
To schedule your building inspection online, please go to
https://aca.anaheim.neUCidzenAccess
Inspection can normally be reached between
7:30.8:00 A.M.
(714)7655153 + 0
To access your inspection timeframe:
Please go to www.anaheim.net/building after 7:30am on the day of your
Inspection. Under Online SeMces, dick on the Ink -Inspection
Timeframes- or call (714) 765.5153 + 0