1225 E CRESTBROOK PL (4)Permit Types
BLD ELE MEC PLM
X X
Permit Number: BLD2018-03586
Issued: 04/29/2020
INSPECTION REQUEST LINE:
(714) 765 - 4626
Quarter Section: 94
Site Address: 1225 E CRESTBROOK PL
Legal Description: N TR 1875 LOT 3
Project Description: Residential Addition: 458 sf. to construct new family room.
C
200 S:-%NAHEIWBL
(714) 765 - 5153
EIM
Q
Living Area: 458 Valuation: $40,000.00
Construcion Types: VB, ,
Fire Sprinklered? No
Cool Roof No
Total Fees paid for Permit: 1,948.19
People Associated with Project:
Owner VASQUEZ MADELIN 1225 E CRESTBROOK PL ANAHEIM CA 92805-4830
Engineer CHRISTINA R SILVA 7652 ONTARIO DR HUNTINGTON BEACH CA 92646
Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Type Mechanical Fixtures Qty
New or total rewire -1 or 2 family 458
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of
permit issuance. A new permit is required to commence or continue work. fbld_permit_combo
City of Anaheim
Building Division
Do not occupy this building until the final inspections have been made.
INSPECTION I DATE INSPECTOR
Do not pour concrete until the following applicable items have been signed:
Plumbing (Ground/Underfloor Drain Waste)
Electrical Ground Electrode/Ufer
Setback/Forms/Trenches (Footings)
Do not install subfloor or pour floor slab until the TMng applicable items have been
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
Floor (Joist(Girders)
Underfloor Insulation (Raised Foundation
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until
1st Floor Shear
2nd Floor Shear
Roof (Sheathing
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough CONMitagation Measures
Framing (Only after Plbg., Ele., Mac. & Fire) 9. -70
Insulation (Sound/Energy)k.lrzy�t
.
Do not tape or plaster until the following applicable items have been signed:
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Service Meter -(Meter will be set within 2-3
business days after approval) Excludes New
Exterior Plaster (Brom
T -Bar (Struct., Ele., or
Grease Interceptor
Backflow
Service
FINAL INSPECTIONS I DATE I
INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
J �G
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
Fire Sprinkler (ONLY) (714) 765-5041
Fire Dept. Final (714) 765-5041
Water Engineering (714) 765-4591
Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days)
COAIMigation Measures
Building Final (714 7654153)
Last Inspection -Final Only After Above Completed
J
PARTIAL INSPECTIONS
Mechanical Inspections
Plumbing Inspections
Electrical Inspections