1317 S COURSON DR (2)City of Anaheim
L BUILDING DIVISION
INSPECTION RECORD
SWIMMING POOL
ADDRESS:
1317 S COURSON DR, ANAHEIM, CA 92804
OWNER:
OBYRNE STACEY L
PERMITM
SWI2022-00081
DATE ISSUED:
07/19/2022
DESCRIPTION:
New Pool/Spa: 354 sf. gunite pool, 58 sf. spa and
DO NOT GUNITE ROCK STRUCTURE
(water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has
been signed.
plumbing for fire pit.
POST THIS CARD WITH THE APPROVED PLANS
IN A CONSPICUOUS PLACE ON THE JOB SITE
Inspection Code Date Inspector
y1. Main Drain 504
2. Electric Bonding 506
3. Steel 508
4. Approval to Gunite 510^
DO NOT GUNITE POOUSPA
until all the above Inspections have been signed.
5. BLD -Steel and Electric bonding
(Rock Structures,Slides Etc)
508
DO NOT GUNITE ROCK STRUCTURE
(water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has
been signed.
6. Underground Electric
512
(/
7. Gas Piping Test
514
8. P -Trap Receptor
$16
9. Backflow
518
fd...G.
10. Deck, Deck Drains,
Equipotential & Accessory
Bondino
520
/d
DO NOT POUR FLATWORK
until all the above inspections have been signed.
11. Rough Electrical 522
12. FencinglDoor Alarms 524
13. Plaster approval 526
DO NOT PLASTER
until all the above inspections have been signed.
14. Final Electric 1 528
Sub -Contractors List MUST be approved and pool cover on site
PRIOR to Pool Final inspection request
FINAL INSPECTION CODE DATE INSPECTOR
15. Rough Demo 527
16. Final 599
MISC. INSPECTIONS Date Inspector
fbldjobcards
Inspections 1.5:
1. All plumbing to be completed and the system pressurized to 35 lbs. with water
or house pressure.
2. All metal within 5 feet of pool water, and all pool equipment, must be bonnded
to pool reinforcing steel with 08 solid copper wire. Niche light shell, deck Inserts,
etc. shall be bonded to pool rebar.
3. Pool equipment is not required to be set at this time.
Inspections 8.10:
1. Underground electric inspected prior to baddilling.
2' Gas line test at 100 for 15 minutes with 150 gauge.
3. When polyethylene gas piping Is used, a certificate from a cerlifted installer
and tracer wire shall be provided per CPC 1210.1.7.2 APPENDIX I.
Inspections 11.13:
1. Rough electric inspection when all wiring is completed and ready prior to the
plastering of pooyspa. Potting compound In place at plastic light niche.
2. Current Code requires that any pool, spa or water feature
contacting water 18 inches or more in depth shall be enclosed by a barrier
adequate to prevent entry of small children. The banter shall comply with
Section 3109 of current CBC and CRC APPDENDIX V specifying the height of
any fence provided as barrier to the pool 8- shall be 60' above grade on the
outside of the fence.
3. Doors from a garage shall meet the requirements for a gate. Glass
windows within 5' of pool water shall be tempered glass.
4. Prior to pre -plaster Inspection, streets, curbs and city sidewalks will be
Inspected for any damage due to construction of pool or spas.
S. Grading complete with positive drainage to street or public way. All
exposed plastic pipe shall be painted to protect from sunlight
Inspections 1416:
1. Gas and Electrical completely removed and 2x2 holes at bottom of pool
andlor Isolated elements.
2. Pool badktilled:
A.) with future build - self -compacting send 95% with recelpt
B.) No future build - any fill.
3. After pod Is operating and in working condition with approved pool cover on
site.
INSPECTION REQUESTS
Inspection requests made prior to 5:00 pm Monday - Friday
will be scheduled on the following workday.
To schedule your building inspection online, please go to
https://aca.anaheim.neUCitizenAccess
Inspection can normally be reached between
7:30.8:00 A.M.
(714)7654153 + 0
To access your inspection timeframe:
Please go to www.anaheim.netlbuilding after 7:30am on the day of your
Inspection. Under Online Services, dick on the link -Inspection
Timeframes' or call (714) 765.5153 + 0