1540 W CHANTICLEER RD (2)Permit Types
BLD ELE MEC PLM
X X I X X
Permit Number: BLD2018-02487
Issued: 11/06/2018
INSPECTION REQUEST LINE:
(714) 765 - 4626
Quarter Section: 56
Site Address: 1540 W CHANTICLEER RD
Legal.Descriptiom N TR 1979 LOT 107
CI
(714) 765 - 5153
EIM
�o
Project Description: Residential Remodel: 1314 sq ft of interior remodel to create (3) new closets in bedrooms, new
non-bearing partion wall in-between bathrooms, new drywall throughout, infill (1) window and install (11) new windows and (1)
sliding door. Mechanical to install new air conditioner, coil, disconnect and relocate furnace to attic with (6) ducts. Electrical to
upgrade main service panel to 200amps, install 100amp subpanel and rewire whole house and garage. Plumbing to change out
water heater. Mechanical, Electrical and Plumbing for fixture upgrades. Work done prior to obtaining permit(s). REF:
INV2017-00673
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of
permit issuance. A new permit is required to commence or continue work. fbld_permit_combo
Valuation:
$50,000.00
Construcion Types:
VB, ,
Fire Sprinklered?
No
Cool Roof
No
Total Fees paid for Permit:
4,431.85
People Associated with Project:
Owner DALE ALLEN GARCIA TRUST
5072 CASA LOMA YORBA LINDA CA 92886-3941
Engineer SHAWN NIKJOO CE36969
-
4879 E LA PALMA AVE STE 204 ANAHEIM CA 92807
Permit Applicant MATTHEW GARCIA
5430 ROUNDUP RD NORCO CA 92860
Type Electrical Fixtures Qty
Type Plumbing Fixtures Qty Type Mechanical Fixtures
Qty
Meter/Disc Sw - under 600 V, up to 200 1
Bath Tub
2 Heating Appliances, including vent
1
amps
Lavatory
2 Residential Registers
6
Sub Panel/Temp Pwr - < 600 V, 0 < amps 1
— 200
Kitchen Sink
1 Compressor/Boiler - up to 15 hp
1
New or total rewire -1 or 2 family 1,314
Garbage Disposal
1 Heating/Cooling Coil
1
New or total rewire - garage/carport 441
Dishwasher
1 Gas System (1-5 outlets)
2
Motors - up to 1 h.p. 1
Washing Machine Rough
1 Ventilation Fan - — 300 cfm on single duct 4
Water Heater
1
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of
permit issuance. A new permit is required to commence or continue work. fbld_permit_combo
P�PNEIM �qt
City of Anaheim o� io
Building Division F z
u >
�'•. �D4NDE0%5
Do not occupy this building until the final inspections have been made.
FINAL INSPECTIONS DATE INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Fieal
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4286
Engineering Final (714) 765-5126
INSPECTION DATE INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pour concrete until the following applicable items have been signed:
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 765-4591
Electrical Ground Electrode/Ufer.
Sub List(Bus. Lic. (714) 765-5194 (Allow 10 business days)
Setback/Forms/Trenches (Footings)
COAIMigation Measures
Do not install subfloor or pour floor slab until the follwing applicable items have been
s' a
Building Final (714 765-5153) �9
Last Inspection-Final Only After Above Completed GC.
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas 1j
PARTIAL INSPECTIONS
Building Inspections
'j—'N ^ i
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre-slab (Compaction/Membrane Reinf.)
Floor (Joist/Girders)
^ 6
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
been sinned-
1st Floor Shear
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
Roof (Sheathing/Diaphragm/Frame)
Masonry (Reinf./Bond Beam/Pre-Grout)
Rough Plumbing (Top Out) 44-
Rough Duct (Mechanical) of
Rough Mechanical W
Rough Electrical
Rough COAIMitagation Measures
Plumbing Inspections
0IG Cq&<S
Framing (Only after Plbg., Ele., Mec. & Fire) it it Q 3-6
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed:
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
qcP0V*P WD V MC
Electrical Service Meter-(Meter will be set within 2-3
business days after approval) Excludes NewConstnicteon �
Exterior Plaster (Brown Coat)
T-Bar (Strutt., Ele., or Mec.)
Grease Interceptor
(Do not backfill unless sioned offi
Sewer
Water Engineering Backflow (Testable Only)
Water Service