Loading...
1930 W CHATEAU AVE (3)Permit Types BLD ELE MEL* X Permit Number: BLD2023-02942 Issued: 06/13/2023 www.anaheim.net/building (714)765.4626 Quarter Section: 41 CITY OF ANAHEIM Site Address: 1930 W CHATEAU AVE, ANAHEIM, CA 92804 Legal Description: N TR 5250 BLK LOT 3 APN: 12830118 BUILDING DIVISION 200 S. ANAHEIM BLVD. (714)765-5153 Project Description: Reroof: Remove existing to install (30) sq of composition shingles over entire house and attached garage Living Area: Number of Stories: 1 Valuation: 19,550.00 Garage Area: Construction Types: NIA Carport Area: Occupancy Groups: Balcony I Dedr Area: Fire Sprinldered: Cool Roof: Total Fees paid for Permit: 341.54 People Associated with Project: Contractor ACCURATE ROOFING 11812 EDGEWOOD LN200508050944257610 GARDEN GROVE, CA 92840 Owner NGUYEN, ANDY 1930 W CHATEU AVE Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures Qty The permit shall expire by limitation and become null and void If the building or work has not passed final inspection 365 days from the date of permit Issuance. A new permit Is required to commence or continue work. P�P<♦EIM �qt Cityof Anaheim o� io Building Division F z U > �DG�►DED 8�^ Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS DATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714) 765-4280 Engineering Final (714) 765-5126 INSPECTION I DATE INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been signed: Fire Dept. Final (714) 765-.5041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765-4591 Electrical Ground Electrode/Ufer Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days) Setback/FormslTrenches (Footings) C 'gation Meellures Do not install subfloor or pour floor slab until the follwing applicable items have been e . Building Final (7 4 765-5153) Last Inspection- al Only Ager Above ompleted -� Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre -slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been s' 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear RoFi—gh'eathin1aphragm/Frame) Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbing Inspections Framing (Only after Plbg., Ele., Mec. & Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed: Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter -(Meter will be set within 2-3 business days after approval) Excludes New Construction Exterior Plaster (Brown Coat) T -Bar (Strutt., Ele., or Mec.) Grease Interceptor (Do not hack Sewer Water Engineering Backflow (Testable Only) Water Service BUILDING DIVISION CITY OF ANAHEIM BUILDING DEPARTMENT 2013 CALIFORNIA CODES 200 S. Anaheim Blvd., Suite 145 CODE CYCLE 01/01/2014 Anaheim, CA 92805 EFFECTIVE DATE 714 765-5153 www.anaheim.net/building SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION ` Final ins ection approval will require this completed form to be on site along with the job card. 1n29 3 Permit Number: �- Date: � '� l —2 Project address: Property Owner: The undersigned does h reby ce-Ifily thati I am the property owner of the above referenced property. I further certify that smo a alarms and carbon monoxide alarms are present and functional in all the following locations. All boxes must be checked below M/Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms. [Smoke Alarms: In each room used for sleeping purposes. IR/Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement; (Note: in dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.) All dwelling units with attached garages require carbon monoxide detectors. Signature: �1f�2' 1 Date: 2 California Residential Code (CRC)- Section R314.6.2,CRC R315.2 States in part that existing dwellings be "retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as indicted above. NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim Inspector is not achieved during the course of project construction. It is normally used for exterior projects such as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work. 200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax SEPT 2015 www.anaheim.net/building B842