Loading...
2217 W CLOVER AVE (6)City of Anaheim BUILDING DIVISION INSPECTION RECORD 0 SWIMMING POOL ADDRESS. 2217 W CLOVER AVE, ANAHEIM, CA 92801 OWNER: JOAN TINSAY EUGENIO PERMITM SW12021-00103 DATE ISSUED: 08/302021 DESCRIPTION: New Pool/Spa: 386 al. gunge pool with 49 sf. gunite DO NOT GUNITE ROCK STRUCTURE (water feature, tock slide, fountain, waterfall, grotto etc.) until the above inspection has been signed. spa. POST THIS CARD WITH THE APPROVED PLANS IN A CONSPICUOUS PLACE ON THE JOB SITE Inspection Code a Inspector 1. Main Drain 504 2. Electric Bonding 506 3. Steel 508 4. Approval to Gunite 510 DO NOT GUNITE POOUSPA until all the above inspections have been signed. 5. BLD -Steel and Electric bonding (Rock Structures,Slh Etc) 508 DO NOT GUNITE ROCK STRUCTURE (water feature, tock slide, fountain, waterfall, grotto etc.) until the above inspection has been signed. 6. Underground Electric 512 7. Gas Piping Test 514 8. P -Trap Receptor 516 / 9. Backflow 518 /7 10. Deck, Deck Drains, 520 r C / Equipotential & Accessory f -7//11 �J J 6 Bondin DO NOT POUR FLATWORK until all the above inspections havq begn signed. 11. Rough Electrical 522 12. Fencing/Door Alarms 524 13. Plaster approval 526 DO NOT PLASTER until all the above inspections have•been signed. 14. Final Electric 528 )- C Sub -Contractors List MUST be approved and pool cover on site PRIOR to Pool Final Inspection request FINAL INSPECTION CODE DATE INSPECTOR 15. Rough Demo 527 16. Final 599 J� MISC. INSPECTIONS Date Inspector fbldjobcerds Insaectfons 1.5: 1. All plumbing to be completed and the system pressurized to 35 lbs. with water or house pressure. 2. All metal within 5 feet of pool water, and all pool equipment, must be bonded to pool reinforcing steel with ea solid copper wire. Niche light shell, deck Inserts, etc, shell be bonded to pool reber. 3. Pool equipment is not required to be set at this time. IM11120pns 1ld- 1. Underground electric inspected prior to backfiling. 2. Gas fine test at 100 for 15 minutes with 150 gouge. 3. when polyethylene gas piping is used, a certificate from a certified Installer and tracer wire shall be provWed per CPC 1210.1.7.2 APPENDIX I. Inspections 1143: 1. Rough electric Inspection when all wiring is completed and reedy prior to the plastedng of poovspa. Patting compound in place at plastic light niche. 2. Current Code requires that any pool, spa or water feature contacting water 1 e inches or mom In depth shall be enclosed by a banter adequate to prevent entry of small children. The border shall comply with Section 3109 of current CBC and CRC APPDENDIX V specifying the height of any fence provided as border to the pool 6- shall be 60' above grade on the outside of the fence. 3. Doors from a garage shag meet the requirements for a gate. Glass windows within For pool water shall be tempered glass. 4. Prior to pre -plaster inspection, streets, curbs and city sidewalks will be Inspected for any damage due to construction of pool or spas. S. Grading complete with positive drainage to street or public way. All exposed plastic pipe shall be palmed to protect from sunlight. Insoections 1x16: 1. Gas and Electrical completely removed and W holes at bottom of pool and/or Isolated elements. 2. Pool bacldilled: A.) with future build - sell -compacting sand 95% with receipt. B.) No future build - any fig. 3. After pool Is operating and In working condition with approved pool cover on she. INSPECTION REQUESTS Inspection requests made prior to 5:00 pm Monday - Friday will be scheduled on the following workday. To schedule your building inspection online, please go to hops://ace.aneheim.net/CitizeMceess Inspection can normally be reached between 7:30 - 8:00 A.M. (714)765.5153 + 0 To access your Insoection timeframe: Please go to www.anahelm.net/buikling after 7:30am on the day of your Inspection. Under Online Services, cfick an the Ink 'Inspection Thmefremes' or call (714) 765.5153 +0