2217 W CLOVER AVE (6)City of Anaheim
BUILDING DIVISION
INSPECTION RECORD
0 SWIMMING POOL
ADDRESS.
2217 W CLOVER AVE, ANAHEIM, CA 92801
OWNER:
JOAN TINSAY EUGENIO
PERMITM
SW12021-00103
DATE ISSUED:
08/302021
DESCRIPTION:
New Pool/Spa: 386 al. gunge pool with 49 sf. gunite
DO NOT GUNITE ROCK STRUCTURE
(water feature, tock slide, fountain, waterfall, grotto etc.) until the above inspection has
been signed.
spa.
POST THIS CARD WITH THE APPROVED PLANS
IN A CONSPICUOUS PLACE ON THE JOB SITE
Inspection Code a Inspector
1. Main Drain 504
2. Electric Bonding 506
3. Steel 508
4. Approval to Gunite 510
DO NOT GUNITE POOUSPA
until all the above inspections have been signed.
5. BLD -Steel and Electric bonding
(Rock Structures,Slh Etc)
508
DO NOT GUNITE ROCK STRUCTURE
(water feature, tock slide, fountain, waterfall, grotto etc.) until the above inspection has
been signed.
6. Underground Electric 512
7. Gas Piping Test 514
8. P -Trap Receptor 516 /
9. Backflow 518 /7
10. Deck, Deck Drains, 520 r C /
Equipotential & Accessory f -7//11 �J J 6
Bondin
DO NOT POUR FLATWORK
until all the above inspections havq begn signed.
11. Rough Electrical 522
12. Fencing/Door Alarms 524
13. Plaster approval 526
DO NOT PLASTER
until all the above inspections have•been signed.
14. Final Electric 528 )- C
Sub -Contractors List MUST be approved and pool cover on site
PRIOR to Pool Final Inspection request
FINAL INSPECTION CODE DATE INSPECTOR
15. Rough Demo 527
16. Final 599 J�
MISC. INSPECTIONS Date Inspector
fbldjobcerds
Insaectfons 1.5:
1. All plumbing to be completed and the system pressurized to 35 lbs. with water
or house pressure.
2. All metal within 5 feet of pool water, and all pool equipment, must be bonded
to pool reinforcing steel with ea solid copper wire. Niche light shell, deck Inserts,
etc, shell be bonded to pool reber.
3. Pool equipment is not required to be set at this time.
IM11120pns 1ld-
1. Underground electric inspected prior to backfiling.
2. Gas fine test at 100 for 15 minutes with 150 gouge.
3. when polyethylene gas piping is used, a certificate from a certified Installer
and tracer wire shall be provWed per CPC 1210.1.7.2 APPENDIX I.
Inspections 1143:
1. Rough electric Inspection when all wiring is completed and reedy prior to the
plastedng of poovspa. Patting compound in place at plastic light niche.
2. Current Code requires that any pool, spa or water feature
contacting water 1 e inches or mom In depth shall be enclosed by a banter
adequate to prevent entry of small children. The border shall comply with
Section 3109 of current CBC and CRC APPDENDIX V specifying the height of
any fence provided as border to the pool 6- shall be 60' above grade on the
outside of the fence.
3. Doors from a garage shag meet the requirements for a gate. Glass
windows within For pool water shall be tempered glass.
4. Prior to pre -plaster inspection, streets, curbs and city sidewalks will be
Inspected for any damage due to construction of pool or spas.
S. Grading complete with positive drainage to street or public way. All
exposed plastic pipe shall be palmed to protect from sunlight.
Insoections 1x16:
1. Gas and Electrical completely removed and W holes at bottom of pool
and/or Isolated elements.
2. Pool bacldilled:
A.) with future build - sell -compacting sand 95% with receipt.
B.) No future build - any fig.
3. After pool Is operating and In working condition with approved pool cover on
she.
INSPECTION REQUESTS
Inspection requests made prior to 5:00 pm Monday - Friday
will be scheduled on the following workday.
To schedule your building inspection online, please go to
hops://ace.aneheim.net/CitizeMceess
Inspection can normally be reached between
7:30 - 8:00 A.M.
(714)765.5153 + 0
To access your Insoection timeframe:
Please go to www.anahelm.net/buikling after 7:30am on the day of your
Inspection. Under Online Services, cfick an the Ink 'Inspection
Thmefremes' or call (714) 765.5153 +0