2273 W COLCHESTER DRPermit Types CITY OF ANAHEIMPLMBLOELEMEC X BUILDING DIVISION 200 S.ANAHEIM BLVD. (714)765-5153 Permit Number;BLD2023-02716 Issued:06/02/2023 www.anaheim.net/bujlding (714)765-4626 Quarter Section:34 Site Address:2273 W COLCHESTER DR,ANAHEIM,CA 92804 Legal Description;N TR 2701 BLK LOT 14 APN:12725203 Project Description:Reroof:To remove existing and install (5449)sq.of composition and shingles over the entire building 1 35,000.00Ltvir>g Area: Garage Area: Carport Area: Balcony /Deck Area: Cool Roof: Number of Stories:Valuation: N/AConstructionTypes: Occupancy Groups: Fire Sprinklered: Total Fees paid for Permit:415.80 People Associated with Project; 2051 E CERRITOS AVE #8C ANAHEIM,CAContractor Permit Applicant Owner DIAZ TOP ROOFING SERVICES EVER DIAZ LEE,ULYSSES KAI JOHN TR 13145 ESSEX DR Qty Type Mechanical FixturesTypeElectricalFixturesPlumbingFixturesQty Qty The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit Issuance.A new permit is required to commence or continue work. DATE INSPECTORFINALINSPECTIONS City of Anaheim Building Division All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714)765-4280 Do not occupy this building until the final inspections have been made.Engineering Final (714)765-5126 Fire Sprinkler (ONLY)(714)765-5041DATEINSPECTORINSPECTION Do nol pour concrete until the following applicable items have been signed:Fire Dept.Final (714)765-5041 Water Engineering (714)765-4591Plumbing(Ground/Underfloor Drain Waste) Sub List/Bus.Lie.(714)765-5194 (Allow 10 business days)Electrical Ground Electrode/Ufer COA^Migation MeasuresSetback/Forms/Trenches (Footings) Do not install subfloor or pour floor slab until the follwing applicable items have been signnfl Building Final (714 765-5153) Last Inspection-Final Only After Above Completed fri.h'Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONSMechanical(Groundwork) Building InspectionsElectrical(Underground Conduit) Pre-slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do nol cover or conceal the work below until the following applicable items have been signed: 1st Floor Shear Mechanical InspectionsFiresprinkler(Rough)(Fire Dept.) 2nd F|opi'Shear i ^6of^^a^ipgffaiaphragm/Frame)/|/^S X" Masonry (Reinf./Bond Beam/Pre-Grout) 7o. V Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Plumbing InspectionsRoughCOA/Mitagation Measures Framing (Only after PIbg.,Ele.,Mec.&Fire) Insulation (Sound/Energy) Do nol tape or plaster until the following applicable items have been signed; Drywall Drywall Penetrations (Ele,Mec &PIbg) Interior Lath Electrical InspectionsExteriorLath Electrical Service Meter-(Meter will be set within 2-3 business days after approval)Excludes New Construction Exterior Plaster (Brown Coat) T-Bar (Struct.,Ele.,or Mec.) Grease Interceptor iDq not backfill unless signed ofi.i Sewer Water Engineering Backflow (Testable Only) Water Service DIVISION CITY OF ANAHEIM BUILDING DEPARTMENT 2016 CALIFORNIA CODES CODE CYCLE 200 S. Anaheim Blvd., Suite 145 01/01/2017 Anaheim, CA 92805 EFFECTIVEDATE 714 765-5153 www.anaheim.net/building SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION " Final inspection approval will require this completed form to be on site along with the job card. Permit Number: 0 0 2023 - OM I Date: Le Project address: Zen W. W Sf-M Dr. MAH -0 YM OA jigW Property Owner: Si III I Df(eFU-014 The undersigned dofis hereby certify that'l am the property owner of the above referenced property. I further certify that smoke alarms and carbon monoxide alarms are present and functional in all the following locations. All boxes must be checked below 1� Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms. Smoke Alarms: In each room used for sleeping purposes. WSmoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement; (Note: in dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.)�� All dwelling u Signature; monoxide detectors. California Reside ode (CR Section .2,CRC R315.2 states in part that existing dwellings be "retrofitted smoke detectors and carbon monoxide detectors when a building permit is issued for work on or in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as indicted above. NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim Inspector is not achieved during the course of project construction. It is normally used for exterior projects such as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work. 200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax FEB 2018 www.anaheim.net/building B842 SMOKE/ CO ALARM REQUIRED LOCATIONS .Bedroom Bedroom Bath Bedroom Kitchen Living Room Figure I Family Room Bedroom Dining Living Room Kitchen Bedroom Bedroom Figure AlltC \ Bedroom Hall Bedroom Living Room Hell Kitchen G.+ Basement Figure 3 REQUIRED SMOKE ALARM LOCATION REQUIRED CARBON MONOXIDE ALARM LOCATION L 1 �I 4• Y Catlin I Acceptable a• Here Never Here �t2• Top of Detector Acceptable Here Wall Figure 4 Garage f 1 i