Loading...
7001 E COUNTRY CLUB LNCITY OF ANAHEIM Perm%, lumber: EM2023-00709 Issued: 02/13/2023 www.anaheim.neUbuilding (714)765-4626 Quarter Section: 204 Site Address: 7001 E COUNTRY CLUB LN, ANAHEIM, CA 92807 Legal Description: N TR 8466 BLK LOT 36 APN:36530101 BUILDING DIVISION 200 S. ANAHEIM BLVD. •L-• (714) 765 -5153 Project Description: Reroof: Remove existing to Install (34) sq of the (PSF 7.2, ICC #1900) and (1) sq of flat roof PVC over entire house Living Area: Number of Stories: 2 Valuation: 35,000.00 Garage Area: Construction Types: NIA Carport Area: Occupancy Groups: Balcony I Dock Area: Fire Sprinldered: -Crml Roof: Total Fees paid for Permit: 1,045.55 People Associated with Project: Contractor HOYT ROOFS INC 1809 N ORANGETHORPE PARKABCDE11140254 ANAHEIM, CA 92801 Permit Applicant Takeo Tokillas Owner SPARACIO CHRISTOPHER S TR 7001 E COUNTRY CLUB LN Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures City The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit issuance. A new permit Is required to commence or continue work. P�PHEIM C�< Cityof Anaheim o� io Building Division F i U > DED % Do not occupy this buildinq until the final inspections have been made. FINAL INSPECTIONS DATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714) 765-4280 Engineering Final (714) 765-5126 INSPECTION I DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been signed: Fire Dept. Final (714) 765-5041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765-4591 Electrical Ground Electrode/Ufer Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days) Setback/Forms/Trenches (Footings) COA/Migation Measures Do not install subfloor or pour floor slab until the follwing applicable items have been sionede Building Final (714 765-5153) ~� Last Inspection-Final Only After Above Completed _ 2 Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Buildinq Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre-slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been s' 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) 7/17/2& Masonry (ReinL/Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbinq Inspections Framing (Only after Plbg., Ele., Mec. & Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed: Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter-(Meter will be set within 2-3 business days after approval) Excludes New Construction Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mec.) Grease Interceptor Sewer Water Engineering Backflow (Testable Only) Water Service r ..I BUILDING DIVISION CITY OF ANAHEIM BUILDING DEPARTMENT 2016 CALIFORNIA CODES CODE CYCLE 200 S. Anaheim Blvd., Suite 145 Anaheim, CA 92805 01/01/2017 714 765-5153 EFFECTIVEDATE www.anaheim.net/building SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION * Final inspection approval will require this completed form to be on site along with the job card. Permit Number: 8LDW 00'709 Z_3 Date: �-'� Project address: 2w ,- rn u ydyy duh h 1 vi Property Owner: lV PXV`t /1 QV lkaa The undersigned does hereby certify that I am the property owner of the above referenced property. I further certify that smoke alarms and carbon monoxide alarms are present and functional in all the following locations. All boxes must be checked below C"Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms. [?/Smoke Alarms: In each room used for sleeping purposes. 13Y�'Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement; (Note: in dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.) All dwelling uni it hed garages require carbon monoxide detectors. Signature: Date: California ResiderftiaL.We (CRC) Section R314.6.2,CRC R315.2 states in part that existing dwellings be "retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as indicted above. NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim Inspector is not achieved during the course of project construction. It is normally used for exterior projects such as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work. 200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax FEB 2018 www.anaheim.net/building B842 ' C.^ SMOKE/ CO ALARM REQUIRED LOCATIONS Bedroom nn Bedroom Family Room Bedroom VD O . Bath Bedroom Dining O Living Room Kitchen Kitchen or Living Room � � � Bedroom Bedroom k , ; •� Figure f Figure 2 Attic Bedroom Hall Bedroom Living Room Hall Kitchen Basement Figure 3 REQUIRED SMOKE ALARM LOCATION REQUIRED CARBON MONOXIDE ALARM LOCATION r .._I 4• Id Ceiling Acceptable J 4• Here Never Here ?t2• Top of Detector Acceptable Here Wall Figure 4 Garage 11 I EXISTING ROOF: Cal Shake Tiles = 5.9 psf NEW CLASS A ROOF: Eagle - Eagle Lightweight (7.2psf) (IAPMO ER -19001 ZOO, 1(0 W F 4X jjj " -j Hyl) ox (low 640-N Zx (P"') PLAN NOTES: 1) THE ROOF SLOPE R 7:12 (UNO) 2) ALL FRAMING INDICATED ON THIS PLAN IS EXISTING UNLESS NOTED OTHERWISE N W *I— E s 3) THE CONTRACTOR SHALL VERIFY THAT THE EXISTING FRAMING SIZE AND SPACING MATCHES THAT SHOWN ON THE ROOF PLAN. SHOULD THERE BEA DISCREPANCY, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SO THAT AN UPDATED REPORT CAN BE PROVIDED. 4) THE SPAN INDICATED IN PARENTHESIS IS THE MAXIMUM SPAN FOR THE FRAMING IN THE GIVEN BAY. SHOULD THE ACTUAL HORIZONTAL SPAN (NOT SLOPING SPAN) EXCEED THAT SHOWN, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SO THAT AN UPDATED REPORT CAN BE PROVIDED. 5) WHERE THE EXISTING FRAMING COULD NOT BE VERIFIED IN THE FIELD DUE TO LIMITED ACCESS OR WAS COVERED WITH FINISHES, IT IS NOTED WITH AN ASTERISK(*). IN THESE INSTANCES THE CONTRACTOR SHALL VERIFY THE FRAMING AFTER THE EXISTING ROOF HAS BEEN REMOVED AND NOTIFY THE ENGINEER IF THE EXISTING FRAMING DOES NOT MEET OR EXCEED THAT WHICH IS INDICATED IN THE REPORT. 6) FRAMING SHOWN HAS NOT BEEN ANALYZED TO SUPPORT STORAGE LOADS. WHERE STORED ITEMS EXIST ABOVE THE EXISTING CEILING JOISTS, IT SHOULD EITHER BE REMOVED OR ELSE SPREAD OUT SO AS NOT TO EXCEED MORE THAN 5 POUNDS PER SQUARE FOOT. Page I Permit Typej BLD ELE MEPLM X Permit Number: BLD2023-00709 Issued: 02/13/2023 www.anaheim.net/building (714)765-4626 Quarter Section: 204 CITY OF ANAHEIM BUILDING DMSION 4a 0. 200 S. ANAHEIM BLVD. Site Address: 7001 E COUNTRY CLUB LN, ANAHEIM, CA 92807 Legal Description: N TR 8466 BLK LOT 36 APN:36530101 (714) 765 - 5153 WORKER'S COMPENSATION DECLARATION: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OR THE LABOR CODE. INTEREST, AND ATTORNEY'S FEES. 1 hereby affirm under penalty of perjury one of the following declarations: 1 have and will maintain a certificate of consent to self4nsure for worker's compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain worker's compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit Is issued. My worker's Compensation insurance carrier and policy are: Cartier. AMERICAN ZURICH INSURANCE COMPANY Policy No.: WC112680504 Expiration Date: 1213112013 Name of Agent: Phone No.: I certify that in the performance of the work for which this permit Is issued, I shall not employ any person in any manner so as to become subject to the workers compensation laws of California, and agree that, if I should become subject to the worker's compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. l3 �� Signature of Applicant Date DECLARATION REGARDING CONSTRUCTION LENDING AGENCY: I hereby affirm under penalty of perjury that there Is a construction lending agency for the performance of the work for which this permit is Issued (Sec.3097.Civ.C): Lender's Name: Lender's Address: LICENSED CONTRACTOR'S DECLARATION: I hereby affirm under the penalty of Pemlury that I am licensed under provisions of chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, an my license is in full force and a Oct. ap -- Contractor Signature Date NUMBER EXPIRATION DATE LICENSE TYPE (S) 606111 12/31/2022 C39, D24, C-2