227 S EMERALD ST (4)R
Permit Types
BLD ELE MEC PLM CITY OF ANAHEIM
X
BUILDING DIVISION
Permit Number: BLD2022-04171 200 S. ANAHEIM BLVD.
Issued: 09/02/2022 (714) 765 -6163
C
www.anaheim.net/building
(714)765-0626
Quarter Section: 40
-------- — ----------------- --------
Site Address: 227 S EMERALD ST, ANAHEIM, CA 92804
Legal Description: N TR 2299 BLK LOT 117
APN: 12804307
Project Description: Reroof: Remove existing material, resheath as necessary and install (15) squares of composition shingles for the
house and attached garage.
Living Area: Number of Stories: 1 Valuation: 8.000.00
Garage Area: Construction Types: N/A
Carport Area: Occupancy Groups:
Balcony / Deck Area: Fire Sprinklered:
Cool Roof: Total Fees paid for Permit: 341.04
People Associated with Project:
Permit Applicant Karen VU
Owner NGUYEN VIET HOANG 226 S AGATE ST
Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures Qty
The permit shall expire by limitation and become null and void If the building or work has not passed final Inspection 365 days from the
date of permit issuance. A new permit Is required to commence or continue work.
City of Anaheim O�Q,t,PHE1M C,t�'O
I FINAL INSPECTIONS I DATE I INSPECTOR I
I All aoollcable items below must be sianed before utilities are released I
amiding ivision F z
u >
.
Do not occupy this building until the final inspections have been made.
Final Gas Test
Electrical Final
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
INSPECTION I DATIF-1 INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pour concrete until the following applicable items have been signed:
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 765-4591
Electrical Ground Electrode/Ufer
Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days)
Setback/Forms/Trenches (Footings)
COA/Migation Measures
Do not install subfloor or pour floor slab until the follwing applicable items have been
Building Final (714 765-5153)
Last Inspection -Final Only After Above Completed
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Buildinq Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
Floor (Joist/Girders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised oundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
been e•
1st Floor Shear
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd FI wasi6r
Roof Sheathi aphragm/Frame) 11
Masonry (Reinf./Bond Beam/Pre-Grout)
Rough'Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough COA/Mitagation Measures
Plumbing Inspections -
Framing (Only after Plbg., Ele., Mec. & Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed:
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter -(Meter will be set within 2-3
business -days after approval) Excludes New
Construction
Exterior Plaster (Brown Coat)
T -Bar (Struct., Ele., or Mec.)
Grease Interceptor
Sewer
Water Engineering Backflow (Testable Only)
Water Service
,f
CITY OF ANAHEIM
BUILDING DEPARTMENT '
200 S. Anaheim Blvd., Suite 145
Anaheim, CA 92805 .,
714 765-5153
www.anaheim.net/building ¢'
SMOKE DETECTORS ANDCARB ONOXIC
* Final inspection approval will require this c p et941orin
2013 CALIFORNIA CODES
CODE CYCLE
01/01/2014
EFFECTIVE DATE
.SELF CERTIFICATION
be on site along with the Job card.
Permit Number; 041-71 Date:
Project address:
d2� rnerald�_ l�natieri� �
Property Owner: Vl t ( AM UV Er -N _
The undersigned does hereby certify that I am the property owner of the above referenced
property. I further certify that smoke alarms and carbon monoxide alarms are present and
functional in all the following locations. All boxes must be checked below
'dl-,,-tmoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each sepRrate
sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms:
. l
Smoke Alarms: In each room used for sleeping purposes.
�moke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement;
(Note: in dwellings or dwelling units with split levels and without an intervening door between
the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level
shall suffice for the adjacent lower level provided that the lower level is less than one full story
below the upper level.)
All dwelling units with attached garages require carbon monoxide detectors.
Signature:
California Residential Code (CRC) Section R314.6.2,CRC R315.2 States in part that existing dwellings be
"retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or
in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as
indicted above.
NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim
Inspector is not achieved during the course of project construction. It is normally used for exterior projects such
as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work.
200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax SEPT 2015
www.anal&.net/building 8842
1
SMOKE/ CO ALAR:6'.REQUIRED LOCATIONS '
Family Room Bedroom
Dining
Living Room
r
Kitchen, _
• s '
i o
Bedroom' Bedroom
Figure 1 V✓ C) Figuce.2 'j 4 -
Ceiling
Acceptable 4-
Here Never -T
. Hen: 12•
Attic r Top of Detector
Acceptable Here.
Wall
Bedroom Hall Bedroom Figure 4 '
.e
Living Room Hall Kitchen
Basement Garage
Figure 3 ;
REQUIREb SMOKE ALARM LOCATION '
y•
4
fo REQUIRED CARBON MONOXIDE ALA+OCATION