407 S HILDA CIR (3)Permit Types
BLD ELE MEC PLM
X X X X
Permit Number: BLD2018-04865
Issued: 06/26/2019
INSPECTION REQUEST LINE:
(714) 765 - 4626
Quarter Section: 123
Site Address: 407 S HILDA CIR .
Legal Description: N TR 4582 LOT 3'
200 SMI ANAHEIM�-BLVD.
(714) 765 - 5153
EIM
Project Description: New Residential Construction: 448 sq ft accessory living quarters with bedroom and bathroom. 358 sq ft
attached solid patio cover that is closed on one side.
Living Area: 434 Valuation: $20,000.00
Patio Area: 266 Construcion Types: VB, ,
Occupancy Groups: R3, , , ,
Fire Sprinklered? No
Total Fees paid for Permit: 4,102.48
People Associated with Project:
Owner LAURA WALDROP 407 S HILDA CIR ANAHEIM CA 928064303
Permit Applicant LAURA WALDROP 407 S HILDA CIR ANAHEIM CA 92806
Type Electrical Fixtures
Sub Panel/Temp Pwr - < 600 V, 0 < amps
<= 200
Receptacle, switches, lights
Qty Type Plumbing Fixtures Qty Type Mechanical Fixtures
1 Bath Tub 1 Compressor/Boiler - tip to 15 hp
Lavatory 1 Heating/Cooling Coil
25 Water Closet 1 Ventilation Fan - <= 300 cfm on single duct
Water Heater 1
Bar Sink 1
Water Distribution 1
Gas System (1-5 outlets) 1
Water Main per 100 ft. 2
Sewer per 100 ft. 2
Qty
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of
permit issuance. A new permit is required to commence or continue work. fbld_permit combo
1
2
1
r
City of Anaheim O�P�Pt1ElIM C9CU
FINAL INSPECTIONS
All applicable items below must be
DATEINSPECTOR
before utilities are released
ismiaing Division IM. i
u >
SOUNDED
Do not occupy this building until the final Inspections have been made.
Final Gas Test
Electrical Final f
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4260
Engineering Final (714) 765-5126
INSPECTION
DATE I INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pourconcxete until the following applicable items h ve been si ned:
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 765.4591
Electrical Ground Electrode/Ufer
Sub List/Bus. Lic. (714) 765-51194 (Allow 10 business days)
Setback/Forms/Trenches (Footings)
0
COA/Migation Measures
Do not install subfloor or pour floor slab until the follwing applicable item ave been
s' e •
Building Final (714 765-5153)
Last Inspection -Final Only After Above Completed
rn -7a
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Building Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (CompactionlMembrane Reinf.) y�
Floor (Joist(Girdem)
Underfloor Insulation (Raised Foundation, Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
ee s' e
1st Floor Shear
Q-gi
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
Roof (Sheathing/Diaphragm/Frame)
Masonry (Reinf./Bond Beam/Pre-Grout)
Rough Plumbing (Top Out)
•
Rough, Duct (Mechanical)
'
Rough Mechanical
•�
Rough Electrical
Rough COAIMitagation Measures
Plumbing Ins ections
Framing (Only after Plbg., Ele., Mec. & Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been gned:
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath.
B••
Maw
lectrical Inspections
Exterior Lath
Electrical Service Meter -(Meter will be set within 2-3
business days after approval) Excludes New
Exterior Plaster (Brown Coat)
T -Bar (Strutt., Ele., or Mec.)
Grease Interceptor
Sewer
,
Water Engineering Backflow, (Testable Only) -
Water Service