407 S HILDA CIR (3)Permit Types BLD ELE MEC PLM X X X X Permit Number: BLD2018-04865 Issued: 06/26/2019 INSPECTION REQUEST LINE: (714) 765 - 4626 Quarter Section: 123 Site Address: 407 S HILDA CIR . Legal Description: N TR 4582 LOT 3' 200 SMI ANAHEIM�-BLVD. (714) 765 - 5153 EIM Project Description: New Residential Construction: 448 sq ft accessory living quarters with bedroom and bathroom. 358 sq ft attached solid patio cover that is closed on one side. Living Area: 434 Valuation: $20,000.00 Patio Area: 266 Construcion Types: VB, , Occupancy Groups: R3, , , , Fire Sprinklered? No Total Fees paid for Permit: 4,102.48 People Associated with Project: Owner LAURA WALDROP 407 S HILDA CIR ANAHEIM CA 928064303 Permit Applicant LAURA WALDROP 407 S HILDA CIR ANAHEIM CA 92806 Type Electrical Fixtures Sub Panel/Temp Pwr - < 600 V, 0 < amps <= 200 Receptacle, switches, lights Qty Type Plumbing Fixtures Qty Type Mechanical Fixtures 1 Bath Tub 1 Compressor/Boiler - tip to 15 hp Lavatory 1 Heating/Cooling Coil 25 Water Closet 1 Ventilation Fan - <= 300 cfm on single duct Water Heater 1 Bar Sink 1 Water Distribution 1 Gas System (1-5 outlets) 1 Water Main per 100 ft. 2 Sewer per 100 ft. 2 Qty The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit issuance. A new permit is required to commence or continue work. fbld_permit combo 1 2 1 r City of Anaheim O�P�Pt1ElIM C9CU FINAL INSPECTIONS All applicable items below must be DATEINSPECTOR before utilities are released ismiaing Division IM. i u > SOUNDED Do not occupy this building until the final Inspections have been made. Final Gas Test Electrical Final f Plumbing Final Mechanical Final Cross Connection Control (714) 765-4260 Engineering Final (714) 765-5126 INSPECTION DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pourconcxete until the following applicable items h ve been si ned: Fire Dept. Final (714) 765-5041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765.4591 Electrical Ground Electrode/Ufer Sub List/Bus. Lic. (714) 765-51194 (Allow 10 business days) Setback/Forms/Trenches (Footings) 0 COA/Migation Measures Do not install subfloor or pour floor slab until the follwing applicable item ave been s' e • Building Final (714 765-5153) Last Inspection -Final Only After Above Completed rn -7a Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre -slab (CompactionlMembrane Reinf.) y� Floor (Joist(Girdem) Underfloor Insulation (Raised Foundation, Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have ee s' e 1st Floor Shear Q-gi Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) • Rough, Duct (Mechanical) ' Rough Mechanical •� Rough Electrical Rough COAIMitagation Measures Plumbing Ins ections Framing (Only after Plbg., Ele., Mec. & Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been gned: Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath. B•• Maw lectrical Inspections Exterior Lath Electrical Service Meter -(Meter will be set within 2-3 business days after approval) Excludes New Exterior Plaster (Brown Coat) T -Bar (Strutt., Ele., or Mec.) Grease Interceptor Sewer , Water Engineering Backflow, (Testable Only) - Water Service