1313 S HARBOR BLVD (426)Permit Types BLD ELE MEC PLM X Permit Number: BLD2022-06019 Issued: 12120/2022 www.anaheim.neUbuilding (714)765-0626 Quarter Section: 76 CITY OF ANAHEIM BUILDING DIVISION 200 S. ANAHEIM BLVD. (7141765-5153 Site Address: 1313 S HARBOR BLVD 8600, Anaheim, CA 92802 Legal Description: S TWP 4 RGE 10 SEC 22 T 4 R 10 SEC 22 POR OF SEC A APN: 08219019 Project Description: Electrical for DLR - SW Launch Bay - Adding (315) receptacles in Exhibition Space REF:BLD2022-03317 Living Area: Number of Stories: 1 Valuation: 0.00 Garage Area: Construction Types: N/A Carport Area: Occupancy Groups: Balcony / Deck Area: Fire Spdnldered: Cool Roof: Total Fees paid for Permit: 338.00 People Associated with Project: Owner WALT DISNEY WORLD CO PO BOX 5046 Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures Qty Receptacle, switches, lights 315 The permit shall expire by limitation and become null and void If the building or work has not passed final inspection 365 days from the date of permit Issuance. A new permit is required to commence or continue work. P�PHEIM Cq< City of Anaheim o4 io Building Division F i u > �DG�►DED � Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS DATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714) 765-4280 Engineering Final (714) 765-5126 INSPECTION I DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been signed: Fire Dept. Final (714) 765-5041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765-4591 Electrical Ground ElectrodelUfer Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days) Setback/Forms/Trenches (Footings) COA/Migation Measures Do not install subfloor or pour floor slab until the follwing applicable items have been sinned: Building Final (714 765-5153) Last Inspection-Final Only After Above Completed Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre-slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been sianedo 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) . Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbinct Inspections Framing (Only after Plbg., Ele., Mec. & Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed: Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections �N Electrical Service Meter-(Meter will be set within 2-3 business days after approval) Excludes New Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mec.) Grease Interceptor Sewer Water Engineering Backflow (Testable Only) Water Service SII r SALASO'BRIEN expect a difference 8825 Res�»rch Orivr_ lrvin�, C.n 926"18 911.9.753.'1553 I www.s�l� sobricn.co n-� Complete Acceptance Letter ELECTRICAL Date of Report: 2023/04/12 Site Visit 2023/03/10 Date: 2023/03/16 To: Thomas Lee Name of Tomorrowland DLR Project: DVC Lounge SOBE Project: #2022-01010 To Whom It May Concern, To the best of our knowledge and belief, based on limited observation, the observed construction generally meets the requirements set forth in the permitted plans and specifications. Since the observations were not performed on a full-time bases, there may be non-compliant items that were not readily observable and cannot be attested. Electrical Scope of Work shown as follows: • Expand existing Men's restroom to add lighting fixtures and plumbing hardware sensors. • Add new Women's restroom with new lighting and plumbing hardware sensors. • Add new beverage center with casework with power for two coffee machines and two soda dispensers. • Add power for news water heater and for two new ceiling fans for the beverage center. • Add CO2 Alarm System and CO2 System conduit to tanks. • Add lighting fixtures and receptacle to plumbing chase. • Reconnect power to new rooftop exhaust fan. • Add new lighting fixtures connected via dimming system throughout the Lounge space. • Provide Power and lighting fixtures with dimming control in the new Decision and Meeting Rooms and LED Drapes. • Add telephone/data Communication Systems outlets throughout the space. • Add Audio System speakers and controls throughout the lounge. • Adjusted controls for existing working lighting fixtures. To the best of our knowledge, based on limited observation, at the previous site walk date 03/10/23 it was noticed: • First floor lighting wall -wash fixture not installed. Q�oFi:ssioro • First Floor rei�►ote-CQLO tem audibles. o q By: Ro L. Lopez, Electrical EOR No. 13442 09/30/24 04�12�2023