1431 E LA PALMA AVE (7)City of Anaheim BUILDING DIVISION INSPECTION RECORD SWBEVIING POOL ADDRESS: 1431 E LA PALMA AVE OWNER: WELLESLEY HOTELS & RESORTS USA PERMIT #: SW12020-00080 DATE ISSUED: 10/8/2020 DESCRIPTION: New Pool/Spa: 2,400 sf. in -ground gunite pool with new deck and equipment enclosure for "WELLESLEY HOTELS 8 CONSPICUOUS PLACE ON THE JOB SITE Inspection Code Date Inspector 1. Main Outlet. 504 2. Electric Bonding. 506 �, q 2f ixim Inwi- 3. Steel. 508 4. Approval to Gunite. 510 DO NOT GUNITE POOL/SPA until all the above inspections have been signed. 5. Steel and bonding. 508 DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until all the above inspections have been signed. 6. Underground elect. 512 7. Gas piping. test. 514 1j4174lg%CA+ ` W 8. P -Trap Receptor. 516 1It 21 19 rf,4Jym 9. Backflow Device. 518 tell .1 cI� 10. Deck, Deck" Drains, & accessory 520 bonding. 4 2 rdtLIBLA DO NOT POUR FLATWORK until the above inspections have been signed. 11. Rough electric. 522 11124121 M 12. Fencing. 524 at I Z -i 13. Plaster approval. 526 wi za s, -WA DO NOT PLASTER until the above ins ections have been si ned. 14. Final Electric. 1 528 3 L7 Sub -Contractors list approve and pool cover in place prior to final 1 spection. 15. FINAL 599 MISC. INSPECTIONS DATE INSPECTOR Inspectors can normally be reached between 7:30 - 8:00 A.M. and 3:30 - 4:30 P.M. (714) 765-5153 + 0 swimcard Inspections 1 - 5: 1. All plumbing to be complete and the system pressurized to 35 lbs. with water or house pressure. 2. All metal within 5 feet of pool water, and all pool equipment, must be bonded to pool reinforcing steel with #8 solid copper wire. Niche light shell, deck inserts, etc., shall be bonded to pool rebar. 3. Pool equipment is not required to be set at this time. Inspections 6 -10: 1. Underground electric inspected prior to backfilling. 2. Gas line test at 10# for 15 minutes, with 15# gauge. 3. When polyethylene gas piping is used, a certificate from a certified installer and a metal tag at the meter shall be provided per CPC 1211.3 APPENDIX I. Inspections 11 -13: 1. Rough electric inspection when all wiring is completed and ready to run prior to the plastering of pool/spa. 2. City ordinance 6.56.010 requires that any pool, spa or water feature containing water 18 inches or more in depth shall be enclosed by a barrier adequate to prevent entry of small children. The barrier shall comply with Section 421 of the current CBC and City of Anaheim ordinance 15.02.060.180 specifying the height of any fence provided as barrier to the pool shall be 60" above grade on the outside of the fence. 3. Doors from a garage shall meet the requirements for a gate. Glass windows within 5' of pool water shall be tempered glass. 4. Prior to pre -plaster inspection, streets, curbs and city sidewalks will be inspected for any damage due to construction of pool or spas. 5. Grading complete with positive drainage to street or public way. All exposed plastic pipe painted to protect from sunlight. Inspections 14 -15: 1. After pool is operating and in working condition, approved pool cover in place. INSPECTION REQUESTS Inspection requests made before 5:00 pm will be scheduled on the following workday. To schedule your building inspection online, please go to hfp://www.anaheim.nettinspectionRequest. You may also request your inspection by calling (714) 765-4626 and continue with the following steps: • Press 1 for inspection function. • Press 1 to schedule inspection. • Press 5 for Swimming Pool inspection. • Enter your permit # 202000080. • Enter the Code number for the inspection requested (indicated in blue). • Press 1 for next business day, or enter date preferred. • Select time preference (Request is subject to inspector's schedule.) To access your inspection timeframe, please go to www.anaheim.net/building after 7:30 am on the day of your inspection. Under Online Services, click on the "Inspection Timeframes" link or call (714) 765-5153 + 0.