963 E MASON LN (16)Permit Types
t1ElAy
C4��
BLD ELE MEC PLM
�� r
X X X X
o`` o
Permit Number: BLD2017-04195�r_
i
Issued: 02/09/2018
INSPECTION REQUEST LINE:
CITM O -F 'ANAHEIM
(714) 765 - 4626
BUI11-DINGjDIVISION
200 S�ANAHEIM>BLVD.
Quarter Section:
(714) 765 - 5153
Site Address: 963E MASON_ LN 91
Legal. Ubscriptiom
Project Description: New Residential Construction: (Plan 3R) Construct new 3 -story with roof top mezzanine, 3 bedroom, 2.5
bath 1,772 sf. single family residence with 447 sf. garage and 68 sf. deck. (Ref:BLD2017-02019)
Living Area: 1,772
Valuation: $200,000.00
Garage Area 447
Construcion Types: VB, ,
Balcony / Deck Area: 68
Occupancy Groups: R3, S2, , ,
Fire Sprinklered? Yes
Cool Roof No
Total Fees paid for Permit: 8,701.24
People Associated with Project:
Contractor TRUMARK CONSTRUCTION SERVICES INC
3001 BISHOP DR 100 SAN RAMON CA 94583
Permit Applicant MAGGI KIBBEE
Engineer JOHNNY R CONAWAY
70G S FLOWER ST STE 2580 LOS ANGELES CA 90017
Engineer BLAKE J ELLIOTT
131 CALLE IGLESIA STE 200 SAN CLEMENTE CA 92672
Engineer ROBERT L WHEELER
THREE HUGHES IRVINE CA 92618
Engineer KEVIN HILLS
THREE HUGHES IRVINE CA 92618
Engineer BEAT ARNET
520 E GOETZ AVE STE A SANTA ANA CA 92707
Engineer HUAN NGUYEN
4400 CAMPUS DR. NEWPORT BEACH CA 92660
Engineer CHRISTOPHER TEXTER
17911 VON KARMAN AVE STE 200 IRVINE CA 92614
Engineer RAYMON GERGES
THREE HUGHES IRVINE CA 92618
Type Electrical Fixtures Qty
Type Plumbing Fixtures Qty Type Mechanical Fixtures Qty
Meter/Disc Sw - under 600 V, up to 200 1
Bath Tub
1 Heating Appliances, including vent 1
amps
Sub Pwr - < 600 V. 0 < amps 1
Shower
1 Heating/Cooling Coil 1
0POanelfremp
Lavatory
4 Compressor/Boiler - up to 15 hp 1
New or total rewire -1 or 2 family 1,772
Water Closet
3 Residential Registers 11
New or total rewire - garage/carport 447
Kitchen Sink
1 Ventilation Fan - — 300 cfm on single duct 7
Motors - up to 1 h.p. 1
Garbage Disposal
1
Repair/Drainage Alteration/Vent Piping 1
Dishwasher
1
Washing Machine Rough
1
Water Heater
1
Water Distribution
1
Gas System (1-5 outlets)
1
Water Main per 100 ft.
1
Sewer per 100 ft.
1
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of
permit issuance. A new permit is required to commence or continue work. fbld_permit_combo
P�Pt1EIAI Cq< FINAL INSPECTIONS DATE INSPECTOR
Cityof Anaheim D� �o All applicable items below must be signed before utilities are released
Building Division F z Final Gas Test
u > Electrical Final 1�
Plumbing Final ti
�DGNDED fah^ Mechanical Final l.;i'g-/ ,� {o�"Aim—
Cross Connection Control (714) 765-4280
Do not occupy this building until the final inspections have been made. Engineering Final (714) 765-5126
INSPECTION I DATE I INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pour concrete until the following applicable items have been signed:
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste) - �•
ater Engineering (714) 765-4591
Electrical Ground Electrode/Ufer . �•
ub List/Bus. Lic. (714) 765-5194 (Allow 10 business days)
Setback/Forms/Trenches (Footings) 0
COAIMigation Measures
Do not install subfloor or pour floor slab until the follwing applicable items ave been
si a
Building Final (714 765-5153)
0 Last Inspection-Final Only After Above Completed
;19
.£d
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Buildinq Inspections
7 =-7-yg mit% T48kA_ oKA4 -r* c.W. .w-"V jV_ AM"
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre-slab (Compaction/Membrane Reinf.) '`
Floor (Joist/Girders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
been s' e •
1st Floor Shear
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
Roof (Sheathing/Diaphragm/Frame)
Masonry (Reinf./Bond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough COAIMitagation Measures
Plumbinq Inspections
Framing (Only after Plbg., Ele., Mac. & Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed:
Drywall
Drywall Penetrations (Ele, Mac & Pibg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter-(Meter will be set within 2-3
business days after approval) Excludes New
Construction
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele., or Mec.)
Grease Interceptor
ass sinned offl
Sewer
Water Engineering Backflow (Testable Only)
Water Service
�•�