Loading...
915 E ORANGEWOOD AVE (7)City of Anaheim BUILDING DIVISION INSPECTION RECORD i SWIMMING POOL ADDRESS: 915 E ORANGEWOOD AVE, ANAHEIM, CA 92802 OWNER: 3. Steel 508 PERMIT#: SWI2020-00097 DATE ISSUED: 04/16/2021 DESCRIPTION: New Pool: 711 sq ft new in -ground gunite pool with DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until the above inspection has been stoned. ADA lift. POST THIS CARD WITH THE APPROVED PLANS IN A CONSPICUOUS PLACE ON THE JOB SITE Inspection Code Qate Inspector 1. Mein Drain 504 �G 2. Electric Bonding 506 3. Steel 508 4. Approval to Gunite 510 DO NOT GUNITE POOUSPA unfit all the above inspections have been signed. 5. BLD -Steel and Electric bonding (Rock Structures,Slides Etc) 508 DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until the above inspection has been stoned. 6. Underground Electric 512 912 611 j {•- 7. Gas Piping Test 514 11 8,^ •� 8. P -Trap Receptor 516 i . Jt. ., _•� 9. Backnow 518 ^- 10. Deck, Deck Drains, Equipotential & Accessory Bonding 520 -7 _ SSC-,' DO NOT POUR FLATWORK until all the above Inspections have been signed. 11. Rough Electrical 522 12. Fencing/Door Alarms 524 13. Plaster approval 526 DO NOT PLASTER until all the above inspections have en signed. 14. Final Electric 528 Sub -Contractors List MUST be approved and pool cover on site PRIOR to Pool Final Inspection request FINAL INSPECTION CODE DATE INSPECTOR 15. Rough Demo 527 16. Final 599 MISC. INSPECTIONS Date Inspector fbldjobcards Inspections 1d: 1. All plumbing to be completed and the system pressurized to 35 lbs. with water or house pressure. 2. All metal within 5 feet of pool water, and all pod equipment, must be bonnded to pod reinforcing steel with #8 solid copper wire. Niche light shell, deck inserts, etc. shall be bonded to pod rebar. 3. Pool equipment is not required to be set at this time. Inspections 0.10: 1. Underground elecMc Inspected prior to backfilling. 2. Gas line test at 100 for 15 minutes with 159 gauge. 3. When polyethylene gas piping is used, a certificate from a certified Installer and tracer wire shall be provided per CPC 1210.1.7.2 APPENDIX I. inspections 11.13: 1. Rough electric Inspection when all wiring is completed and ready prior to the plastering of poollspa. Potting compound in place at plesfight niche. 2. Current Code requires that any pod, spa or water fea e contacting water 16 inches or more in depth shall be enclosed by a barrier adequate to prevent entry of small children. The barrier shall comply with Section 3109 of current CBC and CRC APPOENDIX V specifying the height of any fence provided as barrier to the pool 8- shall be 60- above grade on the outside of the fence. 3. Doom from a garage shall meet the requirements for a gate. Glass windows within S of pool water shall be tempered glass. 4. Prior to pre -plaster inspection, streets, curbs and city sidewalks will be inspected for any damage due to construction of pool or spas. S. Grading complete with positive drainage to street or public way. All exposed plastic pipe shall be painted to protect from sunlight. Inspections 14.16: 1. Gas and EleWlcal completely removed and 2x2 holes at bottom of pool end/or Isolated elements. 2. Pool backfilled: A.) With future build - se0eompacting sand 95% with receipt. B.) No future build - any fill. 3. After pod Is operating and In working condition with approved pod cover on elle. Inspection requests made prior to 5:00 pm Monday - Friday will be scheduled on the following workday. To schedule your building inspection online, please go to https://aca.anaheim.neVC!tizenAccess Inspection can normally be reached between 7:30 - 8:00 A.M. (714)765.5153 + 0 To access your inspection timeframe: Please go to www.anahelm.net/buiiding after 7:30am on the day of your Inspection. Under Online Services, dick on the link -Inspection Timetramee or call (714) 765.5153 + 0