2516 E OSHKOSH AVE (4)City of Anaheim
BUILDING DIVISION
INSPECTION RECORD
SWIMMING POOL
ADDRESS: 2516 E OSHKOSH AVE, ANAHEIM, CA 92806
OWNER: SALTZMAN JOHN 8 BECKY
PERMIT 0: SWI2016-00094
DATE ISSUED: 08/30/2016
DESCRIPTION: New Spa: 64 sq.ft ground gunite spa, relocated pool
equipment, new gas line for fire pit and heater. Work
a...,....a...r,.,.h.�.r..h......,.. a occ-iRRmn4annA07
POST THIS CARD WITH THE APPROVED PLANS
IN A CONSPICUOUS PLACE ON THE JOB SITE
Inspection Code Date Inspector
504
FElechic
nding 506
508
4. Approval to Gunite 510
DO NOT GUNITE POOL/SPA
until all the above Inspections have been signed.
5. BLD -Steel and Electric bonding
(Rock Structures,Siides Etc)
508
DO NOT GUNITE ROCK STRUCTURE
(water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has
been signed.
6. Underground Electric
512
7. Gas Piping Test
514
8. P-Trep Receptor
516
9. Backflow
518
10. Deck, Deck Drains,
Equipotential & Accessory
Bondina
520
DO NOT POUR FLATWORK
until all the above Inspections have been signed.
11. Rough Electrical 522
12. Fencing/DoorAlarms 524 61;23
13. Plaster Plaster approval 526
DO NOT PLASTER
until all the above inspections have been signed.
14. Final Electric 1 528 1
Sub -Contractors List MUST be approved and pool cover on site
PRIOR to Pool Final Inspection request
FINAL INSPECTION CODE DATE INSPECTOR
15. Rough Demo 527
16. Final 599 `w' -J3 'W'44..—
?✓La..—,MISC.INSPECTIONS
MISC. INSPECTIONSDate Inspector
ibldjobcerds
Inseecaons 1d:
I. AN plumbing to be completed and the system pressurized to 35 Its. with water
or house pressure.
2. Al metal within 5 feet of pool water, and all pool equipment, must be bonded
to pool reinforcing steel with 08 solid copper wire. Niche light shell, deck inserts,
etc. shall be bonded to pool rebar.
3. Pool equipment is not required to be set at this time.
Inspections 8.10:
1. Underground electric Inspected prior to baddilling.
2. Gas line test at 100 for 15 minutes with 150 gauge.
3. When polyethylene gas piping Is used, a certificate from a certified Installer
and tracer wire shall be provided per CPC 1210.1.72 APPENDD( I.
Inspections 11+13•
1. Rough electric Inspection when a1 wiring is completed and ready prior to the
plastering of pooVspa. Polling compound In place at plastic light niche.
2. Current Code requires that any pool, spa or water feature
conteding water 18 inches or more in depth shall be enclosed by a barrier
adequate to prevent entry of small children. The barrier shall comply with
Section 3109 of cement CBC and CRC APPDENDDf V specifying the height of
any fence provided as barrier to the pool d- shall be 60- above grade on the
outside of the fence.
3. Doors from a garage shall meet the requirements for a gets. Glass
windows within T of pool water shag be tempered glass.
4. Prior to pre -plaster inspection, streets, curbs and city sidewalks wig be
Inspected for any damage due to construction of pool or spas.
S. Grading complete with positive drainage to street or pubic way. AN
exposed plastic pipe shall be pointed to protect from sunlighL
Inspections 14.16:
1. Gas and Electrical completely removed and 2x2 hobs at bottom of pool
and/or Isolated elements.
2. Pool baddlled:
A) With future build - sell4ompacthg send 95% with receipL
S.) No future build - any 51.
3. After pool Is operating and In working condition with approved pool cover on
site.
INSPECTION REQUESTS
Inspection requests made prior to 5:00 pm Monday - Friday
will be scheduled on the following workday.
To schedule your building Inspection online, please go to
httpsJ/aca.anaheim.neVCitizenAccess
Inspection can normally be reached between
7:30 - 8:00 A.M.
(714)765.5153 + 0
To access your Inspection timeframe:
Please go to www.anaheim.net/buitding after 7:30am on the day of your
Inspection. Under Online Services, dick on the link -Inspection