Loading...
2516 E OSHKOSH AVE (4)City of Anaheim BUILDING DIVISION INSPECTION RECORD SWIMMING POOL ADDRESS: 2516 E OSHKOSH AVE, ANAHEIM, CA 92806 OWNER: SALTZMAN JOHN 8 BECKY PERMIT 0: SWI2016-00094 DATE ISSUED: 08/30/2016 DESCRIPTION: New Spa: 64 sq.ft ground gunite spa, relocated pool equipment, new gas line for fire pit and heater. Work a...,....a...r,.,.h.�.r..h......,.. a occ-iRRmn4annA07 POST THIS CARD WITH THE APPROVED PLANS IN A CONSPICUOUS PLACE ON THE JOB SITE Inspection Code Date Inspector 504 FElechic nding 506 508 4. Approval to Gunite 510 DO NOT GUNITE POOL/SPA until all the above Inspections have been signed. 5. BLD -Steel and Electric bonding (Rock Structures,Siides Etc) 508 DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has been signed. 6. Underground Electric 512 7. Gas Piping Test 514 8. P-Trep Receptor 516 9. Backflow 518 10. Deck, Deck Drains, Equipotential & Accessory Bondina 520 DO NOT POUR FLATWORK until all the above Inspections have been signed. 11. Rough Electrical 522 12. Fencing/DoorAlarms 524 61;23 13. Plaster Plaster approval 526 DO NOT PLASTER until all the above inspections have been signed. 14. Final Electric 1 528 1 Sub -Contractors List MUST be approved and pool cover on site PRIOR to Pool Final Inspection request FINAL INSPECTION CODE DATE INSPECTOR 15. Rough Demo 527 16. Final 599 `w' -J3 'W'44..— ?✓La..—,MISC.INSPECTIONS MISC. INSPECTIONSDate Inspector ibldjobcerds Inseecaons 1d: I. AN plumbing to be completed and the system pressurized to 35 Its. with water or house pressure. 2. Al metal within 5 feet of pool water, and all pool equipment, must be bonded to pool reinforcing steel with 08 solid copper wire. Niche light shell, deck inserts, etc. shall be bonded to pool rebar. 3. Pool equipment is not required to be set at this time. Inspections 8.10: 1. Underground electric Inspected prior to baddilling. 2. Gas line test at 100 for 15 minutes with 150 gauge. 3. When polyethylene gas piping Is used, a certificate from a certified Installer and tracer wire shall be provided per CPC 1210.1.72 APPENDD( I. Inspections 11+13• 1. Rough electric Inspection when a1 wiring is completed and ready prior to the plastering of pooVspa. Polling compound In place at plastic light niche. 2. Current Code requires that any pool, spa or water feature conteding water 18 inches or more in depth shall be enclosed by a barrier adequate to prevent entry of small children. The barrier shall comply with Section 3109 of cement CBC and CRC APPDENDDf V specifying the height of any fence provided as barrier to the pool d- shall be 60- above grade on the outside of the fence. 3. Doors from a garage shall meet the requirements for a gets. Glass windows within T of pool water shag be tempered glass. 4. Prior to pre -plaster inspection, streets, curbs and city sidewalks wig be Inspected for any damage due to construction of pool or spas. S. Grading complete with positive drainage to street or pubic way. AN exposed plastic pipe shall be pointed to protect from sunlighL Inspections 14.16: 1. Gas and Electrical completely removed and 2x2 hobs at bottom of pool and/or Isolated elements. 2. Pool baddlled: A) With future build - sell4ompacthg send 95% with receipL S.) No future build - any 51. 3. After pool Is operating and In working condition with approved pool cover on site. INSPECTION REQUESTS Inspection requests made prior to 5:00 pm Monday - Friday will be scheduled on the following workday. To schedule your building Inspection online, please go to httpsJ/aca.anaheim.neVCitizenAccess Inspection can normally be reached between 7:30 - 8:00 A.M. (714)765.5153 + 0 To access your Inspection timeframe: Please go to www.anaheim.net/buitding after 7:30am on the day of your Inspection. Under Online Services, dick on the link -Inspection Thneframes- or call (714) 765.5153 + 0