936 W PIONEER DRCity of Anaheim BUILDING DIVISION INSPECTION, RECORD SWIMMING POOL ADDRESS: 936 W PIONEER DR, ANAHEIM, CA 92805 OWNER: GARCIA FELIX J 8 RITA M PERMIT#: SWI2022-00056 DATE ISSUED: 05/18/2022 DESCRIPTION: Alteration to Existing: Replace plumbing POST THIS CARD WITH THE APPROVED PLANS IN A CONSPICUOUS PLACE ON THE JOB SITE Inspection Code Da Inspector 1. Main Drain 504 , 2. Electric Bonding 506 3. Steel 50 4. Approval to Gunite 510 DO NOT GUNITE POOUSPA until all the above inspections have been signed. 5. BLD -Steel and Electric bonding (Rock Structures,Slides Etc) 508 „q DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until the bove Inspection has been signed. 6. Underground Electric 512 7. Gas Piping Test 514 8. P -Trap Receptor 516 9. Backflow, 518 10. Deck, Deck Drains, Equipotential & Accessory Bonding 520 DO NOT POUR FLATWORK' until all the above inspections have been s' ned. 11: Rough Electrical 522 12. Fencing/Door Alarms 524 13. Plaster approval 526 _ DO NOT PLASTER until all the above inspections have been signed. 14. Final Electric - = 528 Sub -Contractor List s UST_ be approved and pool cove on site PRIOR to Pool Flnal inspection request FINAL INSPECTION CODEDATE] INSPECTOR 15. Rough Demo 527 16. Final 599 MISC. INSPECTIONS Date Inspector fbldjobcards Inspections 1.5• 1. All plumbing to be completed and the system pressurized to 35 lbs. with water or house pressure. 2. All metal within 5 feet of pool water, and all pool equipment, must be bonnded to pool reinforcing steel with 08 solid copper wire. Niche light shell, deet inserts, etc. shall be bonded to pool rebar. 3. Pool equipment is not required to be set at this time. Inspections 640: „ 1. Underground electric Inspected prior to balling. 2. Gas line test at 100 for 15 minutes with 150 gauge. 3. When polyethylene gas piping is used, a certificate from a certified Installer and tracer wire shall be provided per CPC 1210.1.7.2 APPENDIX 1. Inspections 11.13: 1. Rough electric Inspection when all wiring is completed and ready prior to the plastering of pooyspa. Potting compound in place at plastic light niche. 2. Current Code requires that any pool, spa or water feature contacting water 16 inches or more in depth shall be enclosed by a border adequate to prevent entry of small children. The banter shall comply with Section 3109 of airrent CBC and CRC APPDENDIX V specifying the height of any fence provided as border to the pool 8- shall be 60- above grade on the outside of the fence. 3. Doors from a garage shall meet the requirements for a gate. Glass windows within W of pool water shell be tempered glass. 4. Prior to pre -plaster Inspection, streets, curbs and city sidewalks will be Inspected for any damage due to construction of pool or spas. S. Grading complete with positive drainage to street or public way. All exposed plastic pipe shall be painted to protect from sunlight Inspecupne %16: 1. Gas and Electrical completely removed and 2x2 holes at bottom of pool end/or Isolated elements. 2. Pool backfilled: A.) With future build - seg -compacting sand 95% with receipt. B.) No future build - any fill. 3. After pool Is operating and in working condition with approved pool cover on site. _ -INSPECTION REQUESTS . - Inspection requests made prior to 5:00 ptn Monday - Friday will be scheduled on the following workday. To schedule your building inspection online, please go to https://aca.anaheim.net/CitizenAccess Inspection can normally be reached between 7:30 - 8:00 A.M. (714)7655153 + 0 ti. To access your inspection timeframe: Please go to www.anaheim.net/building after 7:30am on the day of your Inspection. Under Online Services, dick on the link -Inspection Timeframes' or call (714) 765.5153 + 0 CITY OF ANAHEIM Permit Number: SW12022-00056 Issued: 05118/2022 www.anaheim.net/building (714)76514626 Quarter Section: 62 Site Address: 936 W PIONEER DR, ANAHEIM, CA 92805 Legal Description: N TR 1942 BLK LOT 13 APN:25510210 Project Description: Alteration to Existing: Replace plumbing BUILDING DIVISION 200 S. ANAHEIM BLVD. (714) 765 - 5153 People Associated with Project: Contractor DERK'S LANDSCAPING 19902 GRAYLAND AVE CERRITOS, CA Permit Applicant Victor Hernandez Owner GARCIA FELIX J & RITA M 936 W PIONEER DR OWNER - BUILDER DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's License State law for the following reason(s) Indicated below by the checkmark(s) I have placed next to the applicable Items) (Sec. 7031.5 Business and Professions Code: any city or county which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to Its Issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). 0 1, as owner of property, or my employees with wages as their sole compensation, will do L_J all or U portions of the work, and the structure is not intended or offered for sale (Sec. 7044 Business and Professions Code: The Contractors' State License law does not apply to an owner of property who, through employees' or personal efforts, builds or Improves the property, provided that the Improvements are not Intended or offered for sale. If, however, the building or 0 1, as the owner of the property, am exclusively contracting with licensed Contractors to construct the project (Sec. 7044 Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed Contractor oursuant to the Contractors State License Law). I am exempt from licensure under the Contractors, State License Law for the following reason: Date Signature of Property Owner or Authorized Agent WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: Q I have and will maintain a certificate of consent to self4nsure for workers compensation, Issued by the Director of industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 1 have and will maintain workers compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. My workers Compensation Insurance carrier and policy are: Ci;�rtlfy rtiPolicy No.: Expiration Date: n need not be completed If the permit is for one hundred dollars ($100) or less. that in the performance of the work for which this permit is Issued, I shall not employ any person in any manner so as to become subject to the workers compensation laws of California. and agree_ that, if I should become subj to the workees.compensation provisions of Section 3700 of the . Labor Code. I shall forthwith comply with those v 70 -• Y Date �;^ 1 2 2 `.� Signat plicant ' WARNING: FAILUWTO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OR THE LABOR CODE. INTEREST. AND ATTORNEY'S FEES. T CONSTRUCTION LENDING AGENCY LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that there is a construction lending agency for the performance I hereby affirm under penalty of perjury that I am Lenders Information: licensed under provisions of chapter 9 (commencing with Section 7000) of Division 3 of the Business and I hereby certify that I have read this application and state that the information above is correct. I agree Professions Code. to comply with all city ordinances and state laws relating building construction, and hereby authorize representives of this city to enter upon the above mentioned property for inspection purposes. Date. 05/18/2022 Contractor: - Number: SWI2022-00056 Expiration Date Date Signature of Applicant or Agen TYPE: C27, C53 The premit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit issuance. A new permit is required to commence or continue work. Fees paid for Permit: $170.00