6647 E PRINCETON AVE (4)City of Anaheim ,v BUILDING DIVISION INSPECTION RECORD SWIMMING POOL ADDRESS: 6647 E PRINCETON AVE, ANAHEIM, CA 92807 OWNER: DECKER ANTHONY BERNARD IV 8 KAITLIN ELIZABETH PERMIT 9: SWI2023-00003 DATE ISSUED: 02/13/2023 DESCRIPTION: New Pool/Spa: 320 sq ft pool with 90 sq it spa POST THIS CARD WITH THE APPROVED PLANS IN A CONSPICUOUS PLACE ON THE JOB SITE Inspection Code Date Inspector 1. Main Drain 504 2. Electric Bonding 506 3. Steel 508 4. Approval to Gunite 510 DO NOT GUNITE POOLISPA until all the above Inspections have been signed. 5. BLD -Steel and Electric bonding (Rack Strucdures,Slides Etc) 508 DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until the above inspection has been signed. 6. Underground Electric 512 7. Gas Piping Test 514 1 1- 8. P -Trap Receptor 516 9. Backflow 518 10. Deck, Deck Drains, Equipotential & Accessary Bandina 520 �3 DO NOT POUR FLATWORK until all the above inspections have been signed. 11. Rough Electrical 522 12. Fencing/Door Alarms 524 I H 13. Plaster approval 526 p DO NOT PLASTER until all the above Inspections have been signed. 14. Final Electric 528aj-1i-Z3 Sub -Contractors List MUST be approved and pool cover on site PRIOR to Pool Final Inspection request FINAL INSPECTION CODE DATE I INSPECTOR 15. Rough Demo 527 16. Final 599. r1 2 MISC. INSPECTIONS Date Inspector fbldjobcards Inspection 14: 1. All plumbing to be completed and the system pressurized to 35 ms. with water or house pressure. "I All meld will 10fest of pool water, and all pool equipment, must be bounded to pod reinforcing steel with 98 solid copper wire. Niche light shell, deck Inserts, etc. shell be bonded to pod rebar. 3. Pool equipment is not required to be set at this time. 1. Underground electric inspected prior to backfilling. 2. Gas line test at 100 for 15 minutes with 15M gauge. 3. When polyethylene gas piping Is used, a cer i0cate from a certified installer and tracer wire shall be provided per CPC 1210.1.7.2 APPENDIX I. Insoactions 11.13: 1. Rough electric Inspection when all wiring is completed and ready prior to the plastering of pod/spe. Potting compound in place at plastic light niche. 2. Cunrerd Code requires that any pod, spa or water feature contacting water 15 inches or more In depth shall be enclosed by a bonier adequate to prevent entry of small children. The bander shall comply with Section 3109 of current CBC and CRC APPDENDIX V specifying the height of any fence provided as bander to the pod 3- shall be 60' above grade on the outside of the fence. 3. Doors from a garage shad meet the requirements for a gate. Glass windows within F of pod water shall be tempered glass. 4. Prior to pre -plaster inspection, streets, curbs and city sidewalks will be Inspected for any damage due to construction of pool or spas. 5. Grading complete with positive drainage to street or public way. All exposed plastic pipe shall be painted to protect from sunlight. Insoactions 1416 1. Gas and Bectrical completely removed and 2x2 holes at bottom of pool sWor Isolated elements. 2. Pool backfilled: A.) With future build - self -compacting send 95% with recelpt. B.) No future build - any fill. 3. After pool is operating and in working condition with approved pool cover on site. INSPECTION REQUESTS Inspection requests made prior to 5:00 pm Monday - Friday will be scheduled on the following workday. To schedule your building inspection online, please go to hipsJ/aca.anaheim.net/CitizenAccess Inspection can normally be reached between 7:30.8:00 A.M. (714)765.5153 + 0 To access your Inspection timeframe: Please go to www.anaheim.netibullding after 7:30am on the day of your Inspection. Under Online Services, dick on the link'Inspedion Timeframes' or cell (714) 765.5153.0 CITY OF ANAHEIM BUILDING DIVISIONPermit Number: StiV12023-00003 200 S. ANAHEIM BLVD. Issued: 02/13/2023 (714) 765.5153 www.anaheim.net/building (714)765-4626 Quarter Section: 211 Site Address: 6647 E PRINCETON AVE, ANAHEIM, CA 92807 Legal Description: N TR 8375 BLK LOT 76 APN:36508102 Project Description: New Pool/Spa: 320 sq ft pool with 90 sq ft spa People Associated with Project: Contractor CONSTRUCTIV INC 44341 WESTRIDGE DR LANCASTER, CA Permit Applicant Kenneth Fritts Owner DECKER ANTHONY BERNARD IV & KAITLIN E 6647 E PRINCETON AVE OWNER - BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License State Law for the following reason(*) Indicated below by the eheckmark(s) I have placed next to the applicable Items) (Sec. 7031.5 Business and Professions Code: any city or county which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to Its Issuance, also requires the applicant for the permit to file a signed statement that he or she Is licensed pursuant to the provisions of the Contrectore' State License Law Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt from Ileensure and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). 13 I, as owner of property, or my employees with wages as their sole compensation, will do (_) all or( portions of the work, and the structure is not Intended or offered for sale (Sec. 7044 Business and Professions Code: The Contractors' State License Law does not apply to an owner of properly who, through employees' or personal efforts, builds or Improves the property, provided that the Improvements are not Intended or offered for sale. If, however, the building or 0 I, as the owner of the property, am exclusively contracting with licensed Contractors to construct the project (Sec. 7044 Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed Contractor oursuant to the Contractor's State License Law). I am exempt from licensure under the Contractors, State License Low for the following reason: Date Signature of Property Owner or Authorized Agent WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -Insure for worker's compensation, issued by the Director of Industrial Relations as provided for by Sectio 0 of the labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain worker's co*nation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. My worker's Compensat(o insurance carrier and policy are: Cartier. CLEAR SPRING PROPERTY C U COM Policy No.: CWC00625500 This section need not be completed K t he p It Is for one hundred dollars ($100) or less. ❑ 1 certify that in the perfonnan of a work for which this permit is Issued. I shall not employ any person in any manner so as to become subject to the worker's compensation laws Qf�Cel i and agree that, if I should become subject to the worker's compensation provisions of Section 3700 of the LabW Code_ I shall forthwith ci io jJrose 0rovisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OR THE LABOR CODE. INTEREST. AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that there is a construction lending agency for the performance I hereby affirin under penally of perjury that I am Lender's Information: licensed under provisions of chapter 9 (commencing with ''LL SeFtion 70qu) of Division 3 of the Business and I hereby certify that i have read this application and state that the information above is correct. I agree to comply with all city ordinances and state laws relating building construction, and hereby authorize representives of this city to enter upon the above mentioned properly for inspection purposes. Date Signature of Applicant or Agen The premit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit issuance. A new permit is required to commence or continue work. Contractor. Number. SWI2023-00003 TYPE: B Fees paid for Permit: Expiration Date 3/23/2023 •$1,110.75