2656 W RUSSELL AVE• Permit Types
BLD ELE MEC PLM CITY OF ANAHEIM
X
BUILDING DIVISION
Permit Number: BLD2023-02687 200 S. ANAHEIM BLVD.
Issued: 06/01/2023 (714) 765-5153
www.anaheim.net/building
(714)765.4626
Quarter Section: 19
Site Address: 2656 W RUSSELL AVE, Anaheim, CA 92801
Ltpal Description: N TR 3007 BLK LOT 23
APN:01053103
Project Description: Reroof: Remove existing to install (24) sq of composition shingles over entire house and attached garage
Living Area: Number of Stories: 1 Valuation: 25,000.00
Garape Area: Construction Types: MA
Carport Area: Occupancy Groups:
Balcony / Dock Area: Fire Sprinidered:
Cool Roof: Total Fees paid for Permit: 342.25
People Associated with Project:
Contractor COVER ME GREEN ROOFING 36 65TH PLACE201003241417121130 LONG BEACH, CA 90802
Permit Applicant Craig VanDuren
Owner ZWICKL, CHRISTOPHER F 3 KATHLEEN 2656 W RUSSELL AVE
Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures Qty
The permit shall expire by limitation and become null and void If the building or work has not passed final Inspection 365 days from the
date of permit Issuance. A new permit Is required to commence or continue work.
P�PNEiM �9c
City of Anaheim o� �o
Building Division F y
U >
DEC) �a
Do not occupy this building until the final inspections have been made.
FINAL INSPECTIONS DATE INSPECTOR
All applicable Items below must be signed before utilities are released
Final Gas Test
Electrical Final
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
INSPECTION I DATE I INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pour concrete until the following applicable items have been signed:
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 765-4591
Electrical Ground ElectrodelUfer
Sub LISUBus. Lic. (714) 765-5194 (Allow 10 business days)
Setback/Forms/Trenches (Footings)
on easures
Do not install subfloor or pour floor slab until the follwing applicable items have been
s'
ruildial (714 65-5153)
Only After Ab a omple d
Plumbing (GroundlUnderfloor Water)n-Fi
Underfloor Rough Gas
PARTIAL INSPECTIONS
Building Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre-slab (Compaction/Membrane Reinf.)
Floor (JoisUGirders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
been slanedo
1st Floor Shear
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd F ear
oo heathing/ phragmlFrame)
Masonry (Reinf.IBond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough COAIMitagation Measures
Plumbing Inspections
Framing (Only after Plbg., Ele., Mec. & Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed:
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter-(Meter will be set within 2-3
business days after approval) Excludes New
Construction
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele., or Mec.)
Grease Interceptor
(nn not hackfill unipes Maned nM
Sewer
Water Engineering Backflow (Testable Only)
—+--
Water Service
i
BUILDING DIVISION
CITY OF ANAHEIM
BUILDING DEPARTMENT 2016 CALIFORNIA CODES
200 S. Anaheim Blvd., Suite 145 C
LE Anaheim, CA 92805 01/001/201/20177
714 765-5153 EFFECTIVE DATE
www.anaheim.net/building
SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION
* Final inspection approval will require this completed form to be on site along with the job card.
Permit Number: 2� Z -r- , Date:
Project address:
Property Owner: 2�iUk IVVl t7�
The undersigned does hereby certify that I am the property owner of the
property. I further certify that smoke alarms and carbon monoxide alarms
functional in all the following locations. All boxes must be checked below
are present and
Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate
sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms.
Smoke Alarms: In each room used for sleeping purposes.
/11 Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement;
(Note: in dwellings or dwelling units with split levels and without an intervening door between
the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level
shall suffice for the adjacent lower level provided that the lower level is less than one full story
below the upper level.)
All dwelling units with attached garages require carbon monoxide detectors.
t n
Signature:
—W, --
California Residential Code (CRO�Section R314.6.2,CRC R315.2 states in part that existing dwellings be
"retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or
in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as
indicted above.
NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim
Inspector is not achieved during the course of project construction. It is normally used for exterior projects such
as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work.
200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax FEB 2018
www.anaheim.net/building B842
SMOKE/ CO ALARM REQUIRED LOCATIONS
Bedroom Bedroom
Bath & Bedroom
Kitchen
Living Room
Figure 1
Bedroom
Living Room
Family Room Bedroom
Dining
Living Room
Kitchen
Bedroom Bedroom
Figure 2
Attic \
n 6
Hall Bedroom
L Hall Kitchen
6@5
Basement
Figure 3
REQUIRED SMOKE ALARM LOCATION
REQUIRED CARBON MONOXIDE ALARM LOCATION
Acceptable -14' I
Here Never
Here �1r
To of Detector
Acceptable Here
well
Figure 4
Garage