5219 E SHADY GLEN LN (5)Permit Types
BLD ELE MEC*
EC PLM
X X
Permit Number: W 340?Zlll �' b
Issued: 03/10/2023
www.anaheim.net/building
(714)765-4626
Quarter Section: 173
CITY OF ANAHEIM
Site Address: -5219 E SHADY GLEN LN, ANAHEIM, CA 92807
Legal Desi 1ption: N TR 5999 BLK LOT 21
APN:36109304
BUILDING DIVISION
200 S.ANAHEIM BLVD.
(714) 765 - 5153
r0
Project Description: Photovoltaic System with Microinverters: Install residential roof mounted solar system with (36) modules, (36)
microinverters, (3) disconnects, and 225A main service panel
Living Area: Number of stories. 1 Valuation: 26,000.00
Garage Area: Construction Types: NIA
Carport Area: Occupancy Groups:
Balcony I Deck Area: Fire Sprinklered:
Cool Roof: Total Fees paid for Permit: 1,038.38
People Associated with Project:
Contractor SOLARMAX RENEWABLE ENERGY PROVIDE 308012TH STREET201303081329071749 RIVERSIDE, CA 92307
Permit Applicant Bobby XiaoyuYe
Owner MELGOZA PETRONILO JR TR 5219 E SHADY GLEN LN
Engineer - Civil Douglas M Morales 20271 Lighthouse Ln Huntington Beach, CA 9246
Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures Qty
Meter/Disc Sw - Under 600 V, up to 200 1
amps
Microinverter 36
Motors - up to 1 h.p. 3
The permit shall expire by limitation and become null and void if the building or work has not passed final Inspection 365 days from the
date of permit Issuance. A new permit is required to commence or continue work.
P�PNEIM Cq<
City of Anaheim O� io
Building Division F i
u a
DED
Do not occupy this buildinq until the final inspections have been made.
FINAL INSPECTIONS
DATE
INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
INSPECTION I DATE I INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pour concrete until the following applicable items have been signed:
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 7654591
Electrical Ground Electrode/Ufer
Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days)
Setback/FormslTrenches (Footings)
COA/Migation Measures
Do not install subfloor or pour floor slab until the follwing applicable items have been
sbanede
Building Final (714 765-5153)
Last Inspection-Final Only After Above Completed
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Buildinq Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre-slab (Compaction/Membrane ReinL)
Floor (Joist/Girders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
been saaned7
1st Floor Shear
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
Roof (Sheathing/Diaphragm/Frame)
Masonry (Reinf./Bond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough COA/Mitagation Measures
Plumbing Inspections
Framing (Only after Plbg., Ele., Mec. & Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed:
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter-(Meter will be set within 2-3
business days after approval) Excludes New
Construction
Exterior Plaster (Brown Coat)
T-Bar (Strutt., Ele., or Mec.)
Grease Interceptor
Sewer
Water Engineering Backflow (Testable Only)
Water Service