8331 E STARCREST CTCity of Anaheim r1p
BUILDING DIVISION
INSPECTION RECORD
SWIMMING POOL
ADDRESS:
8331 E STARCREST CT, ANAHEIM, CA 92808
OWNER:
PARVIN GREGORY M TR
PERMIT #:
SW12022-00001
DATE ISSUED:
01/07/2022
DESCRIPTION:
New Spa: 48 sq 1t in -ground spa with batbeque and
DO NOT GUNITE ROCK STRUCTURE
(water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has
been signed.
fire pit.
POST THIS CARD WITH THE APPROVED PLANS
IN A CONSPICUOUS PLACE ON THE JOB SITE
nspection Code Date Inspector
504 11 tZ
ding 506 4i el 1
508
FBLDSteel
Gunite 510 ti
DO NOT GUNITE POOUSPA
until all the above Inspections have been signed.
nd Electric bonding
(Rock Structures,Slides Etc)
508
DO NOT GUNITE ROCK STRUCTURE
(water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has
been signed.
6. Underground Electric
512
+U -JR
7. Gas Piping Test
514
Lj -x•22
�3�
8. P -Trap Receptor
516
j2 -V)4�
d714-
9. Backflow
518.
10. Deck, Deck Drains,
Equipotential & Accessory
Bondina
520
S/ /
6 22,
DO NOT POUR FLATWORK
until all the above inspections have been signed.
11. Rough Electrical 522 I-111LIftj -IW
12. Fencing/Door Alarms 524 .
13. Plaster approval 526
DO NOT PLAST R
until all the above Inspections have been signed.
14. Final Electric 528 'Z 5
Sub -Contractors List MUST be approved and pool cover on site
PRIOR to Pool Final Inspection request
FINAL INSPECTION CODE DATE INSPECTOR
15. Rough Demo 527
16. Final 599 '9/j-6 0 -k -A
MISC. INSPECTIONS Date Inspector
fbldjobcards r.
74
Inspections 1-5: `J
1. All plumbing to be completed and the system pressurized to 35 lbs. with water
or house pressure.
2. All metal within 5 feet of pool water, and all pool equipment, must be bonded
to pool reinforcing steel with 08 solid copper wire. Niche light shell, deck Inserts,
etc. shall be bonded to pool rebar.
3. Pool equipment is not required to be set at this time.
Inspections 6.10: y
1. Underground electric Inspected prior to backfilling.
2. Gas line test at 100 for 15 minutes with 150 gauge.
3. When polyethylene gas piping is used, a certificate from a certified Installer
and tracer wire shall be provided per CPC 1210.1.7.2 APPENDIX I.
Inspections 11.13:
1. Rough electric Inspection when all wiring is completed and ready prior to the
plastering of pooyspe. Potting compound In place at plastic light niche.
2. Current Code requires that any pool, spa or water feature
contacting water 16 Inches or more in depth shall be enclosed by a bonier
adequate to prevent entry of small children. The barrier shall comply with
Section 3109 of current CBC and CRC APPDENDIX V specifying the height of
any fence provided as Denier to the pool R- shall be 60' above grade on the
outside of the fence.
3. Doors from a garage shell meet the requirements for a gate. Glass
windows within F of pool water shall be tempered glass.
4. Prior to paster Inspection, streets, curbs and city sidewalks will be
Inspected for any damage due to construction of pool or spas.
S. Grading complete with positive drainage to street or public way. All
exposed plastic pipe shall be painted to protect from sunlight.
Inspections 14.16:
1. Gas and Electrical completely removed and 2x2 holes at bottom of pial
and/or Isolated elements.
2. Pool baddilled:
A.) With future build - seti<ompscting send 95% with recelpt.
B.) No future build - any Pol.
3. After pod is operating and in working condition with approved pod cover on
site.
INSPECTION REQUESTS
Inspection requests made prior to 5:00 pm Monday - Friday
will be scheduled on the following workday.
To schedule your building inspection online, please go to
https://aca.anaheim.neUC!UzenAccess
Inspection can normally be reached between
7:30 - 8:00 A.M.
(7141765-5153 + 0
To access your inspection timeframe:
Please go to www.anaheim.netlbuilding after 7:30am on the day of your
Inspection. Under Online Services, dick on the Bink "Inspection
Timeframes' or cell (714) 7655153 + 0