8331 E STARCREST CTCity of Anaheim r1p BUILDING DIVISION INSPECTION RECORD SWIMMING POOL ADDRESS: 8331 E STARCREST CT, ANAHEIM, CA 92808 OWNER: PARVIN GREGORY M TR PERMIT #: SW12022-00001 DATE ISSUED: 01/07/2022 DESCRIPTION: New Spa: 48 sq 1t in -ground spa with batbeque and DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has been signed. fire pit. POST THIS CARD WITH THE APPROVED PLANS IN A CONSPICUOUS PLACE ON THE JOB SITE nspection Code Date Inspector 504 11 tZ ding 506 4i el 1 508 FBLDSteel Gunite 510 ti DO NOT GUNITE POOUSPA until all the above Inspections have been signed. nd Electric bonding (Rock Structures,Slides Etc) 508 DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has been signed. 6. Underground Electric 512 +U -JR 7. Gas Piping Test 514 Lj -x•22 �3� 8. P -Trap Receptor 516 j2 -V)4� d714- 9. Backflow 518. 10. Deck, Deck Drains, Equipotential & Accessory Bondina 520 S/ / 6 22, DO NOT POUR FLATWORK until all the above inspections have been signed. 11. Rough Electrical 522 I-111LIftj -IW 12. Fencing/Door Alarms 524 . 13. Plaster approval 526 DO NOT PLAST R until all the above Inspections have been signed. 14. Final Electric 528 'Z 5 Sub -Contractors List MUST be approved and pool cover on site PRIOR to Pool Final Inspection request FINAL INSPECTION CODE DATE INSPECTOR 15. Rough Demo 527 16. Final 599 '9/j-6 0 -k -A MISC. INSPECTIONS Date Inspector fbldjobcards r. 74 Inspections 1-5: `J 1. All plumbing to be completed and the system pressurized to 35 lbs. with water or house pressure. 2. All metal within 5 feet of pool water, and all pool equipment, must be bonded to pool reinforcing steel with 08 solid copper wire. Niche light shell, deck Inserts, etc. shall be bonded to pool rebar. 3. Pool equipment is not required to be set at this time. Inspections 6.10: y 1. Underground electric Inspected prior to backfilling. 2. Gas line test at 100 for 15 minutes with 150 gauge. 3. When polyethylene gas piping is used, a certificate from a certified Installer and tracer wire shall be provided per CPC 1210.1.7.2 APPENDIX I. Inspections 11.13: 1. Rough electric Inspection when all wiring is completed and ready prior to the plastering of pooyspe. Potting compound In place at plastic light niche. 2. Current Code requires that any pool, spa or water feature contacting water 16 Inches or more in depth shall be enclosed by a bonier adequate to prevent entry of small children. The barrier shall comply with Section 3109 of current CBC and CRC APPDENDIX V specifying the height of any fence provided as Denier to the pool R- shall be 60' above grade on the outside of the fence. 3. Doors from a garage shell meet the requirements for a gate. Glass windows within F of pool water shall be tempered glass. 4. Prior to paster Inspection, streets, curbs and city sidewalks will be Inspected for any damage due to construction of pool or spas. S. Grading complete with positive drainage to street or public way. All exposed plastic pipe shall be painted to protect from sunlight. Inspections 14.16: 1. Gas and Electrical completely removed and 2x2 holes at bottom of pial and/or Isolated elements. 2. Pool baddilled: A.) With future build - seti<ompscting send 95% with recelpt. B.) No future build - any Pol. 3. After pod is operating and in working condition with approved pod cover on site. INSPECTION REQUESTS Inspection requests made prior to 5:00 pm Monday - Friday will be scheduled on the following workday. To schedule your building inspection online, please go to https://aca.anaheim.neUC!UzenAccess Inspection can normally be reached between 7:30 - 8:00 A.M. (7141765-5153 + 0 To access your inspection timeframe: Please go to www.anaheim.netlbuilding after 7:30am on the day of your Inspection. Under Online Services, dick on the Bink "Inspection Timeframes' or cell (714) 7655153 + 0