107-117 N TOPEKA STPermit Types
BLD ELE M
X EC PLM
Permit Number. BLD202342995
Issued: 06115/2023
www.anaheim.neUbuilding
(714)765.4626
Quarter Section: 83
CITY OF ANAHEIM
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714) 765 -5153
Site Address: 107-117 N TOPEKA ST, ANAHEIM, CA 92805
Legal Description: N TR 14268 BLK LOT 5 UN 24 TRACT 14268, LOT 5 OF P
APN: 93014546
Project Description: Reroof: Remove existing material to install (1,800) sq ft of composition shingle for condo building (107 and 117)
LMng Area: Number of Stories: 2 Valuation: 10,000.00
Garage Area: Construction Types: NIA
Carport Area: Occupancy Groups:
Balcony I Deck Area: Fire Sprinklered: No
Cool Roof. Total Fees paid for Permit: 339.30
People Associated with Project:
Contractor CERTIFIED ROOFING SPECIALISTS 9281 LARKSPUR DRIVE201106221436272010 WESTMINSTER, CA 92683
Permit Applicant Joel Ortiz
Owner SANDERS, JON & ELIZABETH G 117 N TOPEKA ST
Type Electrical Fixtures City Type Plumbing Fixtures Qty Mechanical Fixtures Qty
The permit shall expire by limitation and become null and void If the building or work has not passed final inspection 365 days from the
date of permit Issuance. A new permit is required to commence or continue work.
City of Anaheim
Building Division
v
Do not occupy this building until the final inspections have been made.
INSPECTION I DATE I INSPECTOR
Do not pour concrete until the following applicable items have been signed:
Plumbing (Ground/Underfloor Drain Waste)
Electrical Ground ElectrodelUfer
Setback/Forms/Trenches (Footings)
Do not install subfloor or pour floor slab until the follwing applicable items have been
smanedo
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
Floor (Joist/Girders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
been sionedo
lot Floor Shear
Firesprinkler (Rough) (Fire Dept.)
2nd FI o„ar
o Sheathin Diaphragm/Frame)
send(Reinf./Bond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough COA/Mitagation Measures
Framing (Only after Plbg., Ele., Mec. & Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed:
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Service Meter -(Meter will be set within 2-3
business days after approval) Excludes New
Construction
Exterior Plaster (Brown Coat)
T -Bar (Strutt., Ele., or Mec.)
Grease Interceptor
Sewer
Water Engineering Backflow (Testable Only)
Water Service
FINAL INSPECTIONS I DATE I INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
Fire Sprinkler (ONLY) (714) 765-5041
Fire Dept. Final (714) 765-5041
Water Engineering (714) 765-4591
Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days)
Final (714 765-5153) �O--f—
eti final Only Ager Above Completed ..
13
r7-0-ku /I
Building Inspections
Mechanical Inspections
Plumbing Inspections
Electrical Inspections
CITY OF ANAHEIM
BUILDING DIVISION
BUILDING DEPARTMENT 2013 CALIFORNIA CODES
200 S. Anaheim Blvd., Suite 145 CODE CYCLE
Anaheim, CA 92805 01/01/2014
714 765-5153 EPPECMIEDATE
www.anaheim.net/building
SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION
• Final inspection approval will require this completed form to be on site alonq with the iob card.
Project address:
—"undersigned does hereby certify that I am the property owner of the above referenced
property. I further certify that smoke alarms and carbon monoxide alarms are present and
functional in all the following locations. All boxes must be checked below
Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate
sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms.
Smoke Alarms: In each room used for sleeping purposes.
Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement;
(Note: in dwellings or dwelling units with split levels and without an intervening door between
the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level
shall suffice for the adjacent lower level provided that the lower level is less than one full story
below the upper level.)
All dwelling u .ts with a ached garages require carbon monoxide detectors.
9 0119L;
Signature: Date: IJCJ
California Residential Code (CRC) Section R314.6.2,CRC R315.2 States in part that existing dwellings be
"retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or
in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as
indicted above.
NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim
Inspector is not achieved during the course of project construction. It is normally used for exterior projects such
as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work.
200S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)7652153 Phone (714)765-4607 Fax SEPT 2015
www.anaheim.net/building B842