725 S VERONA STCity of Anaheim
BUILDING DIVISION
INSPECTION RECORD
SWIMMING POOL
ADDRESS:
725 S VERONA ST, ANAHEIM, CA 92804
OWNER:
ONTIVEROS RAY GONZALES TR THE R G & C R
PERMIT #:
SW12022-00050
DATE ISSUED:
05/06/2022
DESCRIPTION:
New Pool/Spa: 340 act It pool with 39 sq ft spa
POST THIS CARD WITH THE APPROVED PLANS
IN A CONSPICUOUS PLACE ON THE JOB SITE
Inspection Code Date Inspector
1. Main Drain 504 r-
2.
2. Electric Bonding 506
3. Steel 508
4. Approval to Gunite , 510
DO NOT GUNITE POOUSPA
until all the above inspections have been signed.
5. BLD -Steel and Electric bonding
(Rock Struetures,Slides Etc)
508
17'_/12-
/! G
DO NOT GUNITE ROCK STRUCTURE(/ -
(water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has
been signed.
6. Underground Electric
512 ,
7. Gas Piping Test
514
8. P -Trap Receptor
51617 �Ibj�z
9. Backflow,
'518 9�.2
10. Deck, Deck Drains,
Equipotential & Accessory
Bonding
520
)
,� 9
DO NOT POUR FLATWORK
until all the above inspections have been signed..
11. Rough Electrical 522 jL.
12. Fencing/Door Alarms 524 2 ZKC007
13. Plaster approval 526 "
DO NOT PLASTER
until all the above inspections have been signed.
14. Final Electric 528 ,Q
Sub -Contractors List MUST be approved and pool cover on site
PRIOR to Pool Final Inspection request
FINAL INSPECTION CODE DATE INSPECTOR
15. Rough Demo 527
16. Final 599 Z,
MISC. INSPECTIONS Date Inspector
fbldjobcards
Insoodfons 1.6:
1. All plumbing to be completed and the system pressurized to 35 lbs. with water
or house pressure.
2. All metal within 5 feet of pool water, and all pool equipment, must be bounded
to pool reinforcing steel with #8 solid copper wire. Niche light shell, deck inserts,
etc. shall be bonded to pool rebar.
3. Pool equipment is not required to be set at this time.
Inspections 6.10:
1. Underground electric inspected prior to backfilling.
2. Gas line test at 10# for 15 minutes with 15# gauge.
3. When polyethylene gas piping Is used, a ceAgicate from a certified Installer
and tracer wire shall be provided per CPC 1210.1.7.2 APPENDIX I.
Insoaetions 11.13:
1. Rough electric Inspection when all wiring is completed end ready prior to the
Plastering of poollspa. Potting compound In place at plastic light niche.
2. Current Code requires that any pool, spa or water feature
contacting water 18 inches or more In depth shall be enclosed by a border
adequate to prevent entry of small children. The barrier shall comply with
Section 3109 of comers CBC and CRC APPDENDIX V specifying the height of
any fence provided as border to the pool &- shall be 60' ebova grade on the
outside of the fence.
/ 3. Doors from a garage shall meet the requirements for a gate. Glass
windows within For pool water shall be tempered glass.
4. Prior to pre -plaster inspection, streets, curbs and city sidewalks will be
inspected for any damage due to construction of pool or spas.
5. Grading complete with positive drainage to street or public way. All
exposed plaetic pipe shall be painted to protect from sunlight.
Inspecdons 1418:
1. Gas and Electrical completely removed and 2x2 holes at bottom of pool
and/or Isolated elements.
2. Pool backfilled: \
A.) With future build - self -compacting send 95% with receipt.
B) No future bund - any 811.
3. After pool Is operating and In working condition with approved pool cover on
site.
INSPECTION REQUESTS
Inspection requests made prior to 5:00 pm Monday - Friday
will be scheduled on the following workday.
To schedule your building inspection online, please go to
httpsJ/aca.anaheim.neVCidzenAccess
Inspection can normally be reached between
7:30 - 8:00 A.M.
(714)765.5153 + 0
To access your Inspection timeframe:
Please go to www.anaheim.net/building after 7:30am on the day of your
Inspection. Under Online Services, dick on the link -Inspection
Timeframes' or call (714) 765.5153 + 0
CITY OF ANAHEIM
Permit Number: SW12022-00050
Issued: 05/06/2022
www.anaheim.net/building
(714)765-4626
Quarter Section: 21
Site Address: 725 S VERONA ST, ANAHEIM, CA 92804
Legal Description: N TR 2874 BLK LOT 109
APN: 12618305
Project Description: New Pool/Spa: 340 sq It pool with 39 sq It spa
People Associated with Project:
Permit Applicant Thomas Rodas
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(7141 765 - 5153
Permit Applicant Ray gOntiveros
Owner ONTIVEROS RAY GONZALES TR THE R G & 725 S VERONA ST
OWNER - BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's License State Law for the following mason(s) indicated below by the
checkmark(s) I have placed next to the applicable Items) (Sec. 7031.5 Business and Professions Code: any city or county which requires a permit to
construct, after, Improve, demolish or repair any structure, prior to Its Issuance, also requires the applicant for the permit to file a signed statement that he
or she Is licensed pursuant to the provisions of the Contractors' State License Law Chapter 9 (commencing with Section 7000) of Division 3 of the
Business and Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. Any violation of Section 7031.5 by any
ap leant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
ifI, as owner of property, or my employees with wages as their sole compensation, will do U) all or"portions of the work, and the structure is not
Intended or offered for sale (Sec. 7044 Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through
employees' or personal efforts, builds or improves the property, provided that the Improvements are not Intended or offered for sale. If, however, the building or
0 I, as the owner of the property, am exclusively contracting with licensed Contractors to construct the project (Sec. 7044 Business and Professions Code:
The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed
Contractor Dursuant to the Contractor's State License Laws:")
I am exempt from licensure under the Contractors, State Licepse Law for the inn reason:
Date Signatur6jil"Aro—Reffy Owner or Authorized Agent
I / WORKER'S COMPENSATION DECLARATION I
I hereby affirm under penalty of perjury one of the following declarations:
❑ 1 have and will maintain a certificate of consent to self -insure for worker's compensation, Issued by the Director of Industrial Relations as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
❑ 1 have and will maintain worker's compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers Compensation insurance carrier and policy are:
Cartier: Policy No.: Expiration Date:
This section need not be completed H the permit is for one hundred dollars (1100) or less.
❑ 1 certify that in the performance of the work for which this permit is Issued, I shall not employ any person in any manner so as to become subject to the
workers compensation laws of California, and agree that, if I should become subject to the workers compensation provisions of Section 3700 of the
Labor Code. l shall forthwith comoly with those Drovisions.
Date Signature of Applicant
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES
AS PROVIDED FOR IN SECTION 3706 OR THE LABOR CODE. INTEREST. AND ATTORNEY'S FEES.
I CONSTRUCTION LENDING AGENCY 11 LICENSED CONTRACTORS DECLARATION I
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance
Lenders Information:
I hereby certify that i have read this application and state that the information above Is correct. I agree
to comply with all city ordinances and state laws relating building construction, and hereby authorize
representives of this city to enter upon the above mentioned property for inspection purposes.
I hereby affirm under penalty of perjury that I am
licensed under provisions of chapter 9 (commencing with
Section 7000) of Division 3 of the Business and
Professions Code.
Date: 05/06/2022
Contractor:
Number. SWI2022-00050 Expiration Date
Date Signature of Applicant or Agen TYPE:
The premit shall expire by limitation and become null and void if the building or work has not passed
final inspection 365 days from the date of permit issuance. A new permit is required to commence or
continue work.
Fees paid for Permit:
$1,103.50