18661 WOODWIND LN (4)City 6f Anaheim
BUILDING DIVISION
INSPECTION RECORD
GO SWIMMING POOL
ADDRESS: 18661 WOODWIND LN, ANAHEIM, CA 92807
OWNER: WILLIAMS KEVIN M TR K M
PERMIT #: SW12022-00054
DATE ISSUED: 05118/2022
DESCRIPTION: New Pool/Spa: Remove existing spa to install new 49
sq ft spa
POST THIS CARD WITH THE APPROVED PLANS
IN A CONSPICUOUS PLACE ON THE JOB SITE
Inspection Code Date Inspector
1. Main Drain 504 A Nil'
2. Electric Bonding 506
3. Steel 508 �r 6
4. Approval to Gunite 510
DO NOT GUNITE POOUSPA
until all the above Inspections have been signed.
5. BLD -Steell and Electric bonding
(Rock Structures,Slides Etc)
508
DO NOT GUNITE ROCK STRUCTURE
(water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has
been signed.
6. Underground Electric
512
7. Gas Piping Test
514
M
8. P -Trap Receptor
516 !
1
9. Backflow
518
10. Deck, Deck Drains,
Equipotential & Accessory
Bondina
'520
I"
DO NOT POUR FLATWORK
until all the above Inspections have been signed.
11. Rough Electrical 522
12. Fencing/Door Alarms 524
13. Plaster approval 526 Ili 4 fe,
DO NOT PLASTER
until all the above Inspections have been signed.
14. Final Electric - - 1 528
Sub -Contractors List MUST be approlea dind pool cover on site
PRIOR to Pool Final inspection request
FINAL INSPECTION _ CODEDATE INSPECTOR
15. Rough Demo 527 -
16. Final 599
MISC. INSPECTIONS D t ins p ctor
fbldjobcords
Inspectors 1.6:
1. All plumbing to be completed and the system pressurized to 35Its. with water
or house pressure.
2. All metal within 5 feet of pool water, and all pool equipment, must be bonnded
to pool reinfordng steel with #8 solid copper wire. Niche light shell, deck Inserts,
etc. shall be bonded to pool rebar.
3. Pool equipment is not required to be set at this time.
Inspections 6.10• J
1. Underground electric inspected prior to backfilling.
2. Gas line test at 10# for 15 minutes with 150 gauge.
3. When polyethylene gas piping is used, a certificate from a certified installer
and tracer wire shall be provided per CPC 1210.1.7.2 APPENDIX 1. '
Inspections 11.13:
1. Rough electric inspection when all wiring Is completed and ready prior to the
plastering of pool/spa. Potting compound In place at plastic light niche.
2. Current Code requires that any pool, spa or water feature
contacting water 18 Inches or more in depth shall be enclosed by a bonier
adequate to prevent entry of small children. The bonier shall comply with
Section 3109 of current CBC and CRC APPDENDIX V specifying the height of
any fence provided as border to the pool 8- shall be 60' above grade on the
outside of the fence.
3. Doors from a garage shall meet the requirements for a gate. Glass
windows within F of pool water shall be tempered glass.
4. Prior to pre -plaster inspection, streets, curbs and dly a!dewalks will be
inspected for any damage due to construction of pool or spas.
S. Grading complete with positive drainage to street or public way. All
exposed plastic pipe shall be painted to protect from sunlight.
Insoedlons 14.16:
1. Gas and Electrical completely removed and 2x2 hole_ s at bottom of pool
and/or Isolated elements.
2. Pool backfilled:
A.) With future build - self-compading send 95'% with receipt.
B.) No future build - any fill.
3. After pool Is operating and In working condition with approved pool cover an
site.
INSPECTION REQUESTS
" Inspection requests made prior to 5:00 pm Monday - Friday
- will be scheduled an the following workday.
To schedule your building inspection online, please go to � -r!--
https://aca.anaheim.nef/CiflzenAccess
Inspection can normally be reached between
7:30 - 8:00 A.M.
(714)785.5153 + 0
To access your inspection timeframe:
Please go to www.anahelm.netlbuilding after 7:30am on the day of your
Inspection. Under Online Services, dick an the link -Inspection
Timeframes- or call (714) 765-5153 + 0
CITY OF ANAHEIM
Permit Number: SW12022.00054
Issued: 05/18/2022
www.anaheim.net/building
(714)765-4626
Quarter Section: 171
Site Address: 18661 WOODWIND LN, ANAHEIM, CA 92807
Legal Description: N TR 4926 BLK LOT 9
APN: 34302102
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714) 765 - 5153
Project Description: New Pool/Spa: Remove existing spa to install new 49 sq ft spa
People Associated with Project:
Contractor PATICK G GALLIGAR 1757 N TYMPANI CIRCLE202104271411404560 ANAHEIM, CA 92807
Permit Applicant Patrick Galligar
Owner WILLIAMS KEVIN M TR K M
18661 WOODWIND LN
OWNER - BUILDER DECLARATION
1 hereby affirm under penalty of perjury that 1 am exempt from the Contractor's License State Law for the following reason(s) Indicated below by the
eheckmark(s) I have placed next to the applicable Item(s) (See. 7031.5 Business and Professions Code: any city or county which requires a permit to
construct, after, Improve, demolish or repair any structure, prior to Its Issuance, also requires the applicant for the permit to file a signed statement that he
or she is licensed pursuant to the provisions of the Contractors' State License Law Chapter 9 (commencing with Section 7000) of Division 3 of the
Business and Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. Any violation of Section 7031.5 by any
applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
0 1, as owner of property, or my employees with wages as their sole compensation, will do U all or (__) portions of the work, and the structure Is not
Intended or offered for sale (Sec. 7044 Business and Professions Code: The Contractors' State License Low does not apply to an owner of property who, through
employees' or personal efforts, builds or improves the property, provided that the Improvements are not Intended or offered for sale. If, however, the building or
0 I, ss the owner of the property, am exclusively contracting with licensed Contractors to construct the project (Sec. 7044 Business and Professions Code:
The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed
Contractor oursuant to the Contractor's State License Law).
I am exempt from licensure under the Contractors, State License Law for the following reason:
Date Signature of Property Owner or Authorized Agent
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
❑ I have and will maintain a certificate of consent to self -insure for worker's compensation, Issued by the Director of Industrial Relations as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
❑ 1 have and will maintain worker's compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My worker's Compensation Insurance carer and policy are:
Carrier. Policy No.: Expiration Date:
trrrT����h1111is section need not be completed If the permit Is for one hundred dollars ($100) or less.
" 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person In any manner so as to become subject to the
V
tees compensation laws of California, and agree; should become subject to the worker's compensation provisions of Section 3700 of the
.Labor Code. I shall forthwith comoly with those D sions. — -
AIV Date ignature -
COV
WAR URE WORKERS' COMPENSATIO ERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES_
AS PROVIDED FOR IN SECTION 3706 OR THE LABOR CODE. INTEREST. AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY IF LICENSED CONTRACTORS DECLARATION
I hereby affirm under penalty of perl'ury that there is a construction lending agency for the performance
Lender's Information:
I hereby certify that i have read this application and state that the Information above Is correct. I agree
to comply with all city ordinances and state laws relating building construction, and hereby authorize
representives of this city to enter upon the abc�ve'mpntioned property for inspection purposes.
The premit shall expire by limitation and become null and void if the building or work has not passed
final inspection 365 days from the date of permit issuance. A new permit is required to commence or
continue work.
I hereby affirm under penalty of perjury that I am
licensed under provisions of chapter 9 (commencing with
Section 7000) of Division 3 of the Business and
Professions Code.
Date: 05/18/2022
Contractor: PATICK GALLIGAR
Number: SW12022-00054 Expiration Date
TYPE: C53
Fees paid for Permit: , $1,112.00