Loading...
1707 S BROOKHURST ST (3)^//Permit Types CITY OF ANAHEIMPLMBLDELEMEC X X BUILDING DIVISION 200 S.ANAHEIM BLVD. (714)765-5153 PetTnit Number;BLD2021-01731 Issued:02/18/2022 www.anaheim.net/building {714)765-4626 Quarter Section;36 Site Address:1707 S BROOKHURST ST.ANAHEIM.CA 92804 Legal Description:TR 2773 LOT 67 POR OF LOT APN:12760328 Project Description:Tenant Improvement:Install new kitchen hood. 0 Valuation:10,000.00LIvirtgArea; Garage Area: Carport Area: Balcony /Deck Area: Cool Roof: Number of Stories; VBConstructionTypes; Occupancy Groups; Fire Sprinklered: Total Fees paid for Permit: No 912.80 People Associated with Project: Permit Applicant Owner Engineer -Mechanical Engineer -Civil 1707 S BROOKHURST ST ANAHEIM.CA 92804 9351 DARROW DR HUNTINGTON BEACH.CA 92646 2416 W VALLEY BLVD201710171207578860 ANAHEIM,CA 91803 13902 HARBOR BLVD #2A GARDEN GROVE,CA 92843 MOHD HURANI SUSAN NA TR RAYMOND ZHONG BAO D PHAM Qty TypeTypeElectricalFixtures Plumbing Fixtures Qty Mechanical Fixtures Qty Commercial Hoods (including ducts) The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit issuance.A new permit is required to commence or continue work. DATE INSPECTORFINALINSPECTIONSEiMCityofAnaheim Building Division All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714)765-4280 Do not occupy this building until the final inspections have been made,Engineering Final (714)765-5126 Fire Sprinkler (ONLY)(714)765-5041DATEINSPECTORINSPECTION Do not pour concrete until the following applicable items have been signed;Fire Dept.Final (714)765-5041 Water Engineering (714)765-4591Plumbing(Ground/Underfloor Drain Waste) Sub List/Bus.Lie.(714)765-5194 (Allow 10 business days)Electrical Ground Electrode/Ufer COA/Migation MeasuresSetback/Forms/Trenches (Footings) Do not install subtloor or pour floor slab until the foilwing applicable items have been Signed:^ Building Final (714 765-5153) Last Inspection-Final Only After Above CompletedPlumbing(Ground/Underfloor Water) Underfloor Rough Gas Mechanical (Groundwork) Building Inspections j|Sj3P£QXIONElectrical(Underground Conduit) Pre-slab (Compaction/Membrane Reinf.)NOT COMPLETEDFloor(Joist/Girders) Underfloor Insulation (Raised Foundation Only) WE:Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been sic:-'ed ^^ 1st Floor Shear Mechanical InspectionsFiresprlnkler(Rough)(Fire Dept.) ^c2ndFloorShear ✓“£- IRoof(Sheathing/Diaphragm/Frame)Ll±i-fr Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Plumbing InspectionsRoughCOA/Mitagation Measures Framing (Only after PIbg..Ele.,Mec.&Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed: Drywall Drywall Penetrations (Ele,Mec &PIbg) Interior Lath Electrical InspectionsExteriorLath Electrical Service Meter-(Meter will be set within 2-3 business days after approval)Excludes New Construction Exterior Plaster (Brown Coat) T-Bar (Struct.,Ele.,or Mec.) Grease Interceptor iDo not backtili uc^lc-ss gianed oil Sewer Water Engineering Backflow (Testable Only) Water Service