Staff Report
200 S. Anaheim Blvd.
Suite 162
Anaheim, CA 92805
Tel: (714) 765-5139
Fax: (714) 765-5280
www.anaheim.net
ITEM NO. 2
PLANNING COMMISSION REPORT
City of Anaheim
PLANNING & BUILDING DEPARTMENT
DATE: OCTOBER 23, 2023
SUBJECT: DEVELOPMENT APPLICATION NO. 2022-00060
LOCATION: 30 East Orangethorpe Avenue and 1636 North Lemon Street
APPLICANT/PROPERTY OWNER: The agent is Adan Madrid representing the
applicant Fabiola Yvette Suarez of Pollo Campero. The property owner is CB
Orangethorpe Partners, LLC.
REQUEST: The applicant requests approval of a conditional use permit to construct a
new 2,100 square foot drive-through restaurant and an administrative adjustment to
permit fewer parking spaces than required by the Zoning Code (10% reduction
proposed).
RECOMMENDATION: Staff recommends that the Planning Commission adopt the
attached resolution, determining that a Common Sense Exemption under the California
Environmental Quality Act (CEQA) (Public Resources Code, Sections 21000-
21189.57) as set forth in Sections 15061 (b)(3) of the State CEQA Guidelines
(California Code of Regulations, Title 14, Chapter 3, Sections 15000-15387) is the
appropriate environmental documentation for this request and approving Development
Application No. 2022-00060.
BACKGROUND: The project site is 0.58 acres and consists of two properties
developed with a five-unit commercial retail center and a smog test facility. The project
site is in the “C-G” General Commercial Zone and is designated for Regional
Commercial land uses in the General Plan. The surrounding uses include restaurant and
retail uses to the south, east, and to the north across Orangethorpe Avenue, and
commercial uses located in the City of Fullerton to the west across Lemon Street.
PROPOSAL: The applicant proposes to construct a new 2,100 square foot restaurant
with a single drive-through lane for a Pollo Campero restaurant. The site would have
driveway access from both Orangethorpe Avenue and Lemon Street. The drive-through
lane is located to the south of the property and is designed to circulate behind the
building with vehicles exiting to Orangethorpe Avenue. There would be a single
queuing lane with a capacity for 9 vehicles. The project is designed to provide a total of
19 parking spaces, including two handicap-accessible spaces located at the western
entrance to the building. Extensive landscaping improvements are proposed within the
parking area, along both street frontages, and in the area designated for future right -of-
way improvements along Lemon Street.
Development Application No. 2022-00060
October 23, 2023
Page 2 of 6
Site Plan
Building Design: The building elevations will incorporate various modern architectural features,
including a varied roofline, steel canopies over customer entrances, aluminum awnings, and the
use of porcelain tile to create a break in the stucco finish. The building will be painted in Pollo
Campero corporate colors that include a combination of dark brown, orange, lime green, and light
tan.
Development Application No. 2022-00060
October 23, 2023
Page 3 of 6
Building Elevations
FINDINGS AND ANALYSIS:
Conditional Use Permit: Before the Planning Commission may approve a conditional use permit,
it must make a finding of fact that the evidence presented shows that all of the following conditions
exist:
1) That the proposed use is properly one for which a conditional use permit is authorized by
this code;
2) That the proposed use will not adversely affect the adjoining land uses, or the growth and
development of the area in which it is proposed to be located;
3) That the size and shape of the site proposed for the use is adequate to allow the full
development of the proposed use, in a manner not detrimental to either the particular area
or health and safety;
4) That the traffic generated by the proposed use will not impose an undue burden upon the
streets and highways designed and improved to carry the traffic in the area; and
5) That the granting of the conditional use permit under the conditions imposed, if any, will
not be detrimental to the health and safety of the citizens of the City of Anaheim.
The Zoning Code (“Code”) permits drive-through restaurants in the “C-G” Zone subject to the
approval of a conditional use permit to ensure compatibility with the surrounding area and uses.
Development Application No. 2022-00060
October 23, 2023
Page 4 of 6
Through the conditional use permit process, conditions of approval may be imposed to ensure that
the use would operate in a manner that does not create nuisances, affect the general health and
welfare of the community, and not adversely affect surrounding properties.
The proposed drive-through restaurant uses would not adversely affect the existing uses in the
vicinity and would be compatible and consistent with other commercial and retail uses in the
surrounding area. In addition, the development would be consistent with the commercial retail
and land use pattern in the vicinity and the neighboring commercial shopping centers located in
the City of Fullerton. Further, the proposed size and shape of the subject site would allow for the
full development of the proposed use; and the proposed use would not be detrimental to the area
or the general health and safety of the community. The project has been designed to provide
adequate circulation, meet all landscape and structural setbacks, and would not affect the adjoining
land uses.
The application was reviewed by the City’s Traffic and Transportation Division and determined
that the proposed drive-through restaurant use would not have a significant impact on traffic, that
there would be adequate on-site circulation, and that adequate queuing would be provided for the
drive-through lane. There are other restaurants in the area that have similarly sized buildings with
drive-through lanes. Additionally, a new 2,350 square foot drive-through restaurant is proposed in
the adjacent commercial retail center to the east. Fire and emergency service access were deemed
adequate by the Fire and Rescue Department, and sanitation service was deemed adequate by the
Public Works Streets and Sanitation Division. The traffic generated by the proposed use would
not impose an undue burden on streets and highways in the area.
The granting of the conditional use permit under the conditions imposed will not be detrimental
to the health and safety of the citizens of the City of Anaheim. Conditions of approval are included
in the draft resolution to ensure the restaurant property will be properly maintained and compatible
with the area and adjacent land uses.
Administrative Adjustment: Administrative adjustments are waivers of certain development
standards, including parking requirements, and can be approved by the Planning and Building
Director. When an administrative adjustment application is made in conjunction with a project that
requires Planning Commission action, all requests are subject to review and approval by the
Planning Commission. Before the Planning Commission may approve an administrative
adjustment, it must make the following findings of fact:
1) The adjustment is consistent with the purposes and intent of the Zoning Code;
2) The same or similar result cannot be achieved by using provisions in the Zoning Code that
do not require adjustment;
3) The adjustment will not produce a result that is out of character or detrimental to the
neighborhood.
The applicant requests an administrative adjustment to permit fewer parking spaces than required
by the Code. The Code permits a deviation of up to 20% from the parking requirements through
an administrative adjustment. The proposed drive-through restaurant would require 21 parking
spaces and 19 parking spaces are proposed, representing a 10% reduction in code-required spaces.
The applicant provided a Parking Demand Assessment that surveyed three Pollo Campero
restaurants. The three locations range in size from 2,450 square feet to 2,800 square feet and
Development Application No. 2022-00060
October 23, 2023
Page 5 of 6
provide a range of parking spaces, from 13 parking spaces to 25 parking spaces. The proposed
building is smaller than all three locations in the survey and provides more parking than two of the
locations in the survey. The assessment surveyed a weekday (Thursday) and a weekend (Saturday)
for parking counts. During both peak hour demands for the weekday and weekend, the peak
parking demand observed was 13 spaces. The proposed location not only is smaller than the other
locations in the assessment, but it also provides more parking than the peak parking demand
observed for any of the three locations. Based on the findings from the Parking Demand Analysis,
staff believes that the proposed 19 parking spaces would provide adequate parking for the proposed
project.
The applicant analyzed alternative options that would comply with the parking requirements in the
Code. The first option was to reduce the dining room seating from 26 seats to 20 seats. The Code
requires a lesser parking rate for restaurants with 20 seats or less. This reduction would change
the parking requirement from 21 parking spaces to nine parking spaces. The applicant does not
believe that nine parking spaces would be adequate for the project based on the operational
characteristics of other Pollo Campero restaurants. The other option the applicant identified would
be to reduce the size of the building from 2,100 square feet to 1,900 square feet. This reduction
would reduce the parking requirement to 19 spaces, matching the number of parking spaces
provided. A 1,900 square foot restaurant is significantly smaller than the typical Pollo Campero
restaurant and would impact the daily operations of the restaurant. The dining room area is
approximately 350 square feet in size and any reduction in the square footage would significantly
reduce the dining room area.
The proposed administrative adjustment will not produce a result that is out of character or
detrimental to the neighborhood as other restaurant locations within the vicinity of the project site
are similar in size or smaller. There are other restaurants in the area that have similarly sized
buildings with drive-through lanes. Additionally, a new 2,350 square foot drive-through restaurant
is proposed in the adjacent commercial retail center to the east. Staff does not believe that the
reduction of two parking spaces would be out of character or detrimental to the neighborhood as
the parking assessment for the project identified that 19 spaces would be adequate to support the
restaurant.
Environmental Impact Analysis: Staff recommends that the Planning Commission find that the
effects of the proposed project are Exempt from the requirements to prepare additional
environmental documentation per California Environmental Quality Act (CEQA) Guidelines,
Section 15061 (b)(3) – Common Sense Exemption. This exemption is appropriate where it can be
seen with certainty that there is no possibility that the activity may have a significant effect on the
environment.
The proposed project includes the construction of a new 2,100 square foot drive-through
restaurant, associated parking, landscaping, and signage. The proposed project also includes the
demolition of the existing commercial buildings. The proposed project scope is consistent with a
project that has been determined to not have a significant effect on the environment and therefore
exempt from CEQA pursuant to Section 15303 – New Construction of Conversion of Small
Structures (Class 3). However, because the property had a cleanup and abatement order from the
Regional Water Quality Control Board, it is not eligible to utilize the Class 3 exemption even
though the case was closed in 1988 and a No Further Action Letter was issued. A Phase 1
Environmental Site Assessment (ESA) was conducted in February 2019 and found no reportable
contamination in the soil or groundwater. The Phase 1 ESA recommended that a Limited Phase 2
Development Application No. 2022-00060
October 23, 2023
Page 6 of 6
Subsurface Investigation be conducted including an investigation on shallow soil vapors. After the
Limited Phase 2 Subsurface Investigation was complete, it was found that no significant soil
contamination was detected. Therefore, the Common Sense exemption that CEQA applies only to
projects which have the potential for causing a significant effect on the environment is applicable
to the proposed project.
CONCLUSION: The site has been designed to provide adequate parking and on-site
circulation/queuing. The building would be of a quality design, and extensive landscaping would
be provided to complement the proposed project and be an improvement over the existing site
conditions. Based on the analysis included in this report and the findings contained in the draft
resolution, staff recommends that the Planning Commission approve this request.
Prepared by, Submitted by,
Ivan Orozco Scott Koehm, AICP
Associate Planner Principal Planner
Attachments:
1. Draft Conditional Use Permit and Administrative Adjustment Resolution
2. Project Plans
3. Letter of Request and Findings
4. Pollo Campero Traffic Circulation and Parking Demand Assessment
5. Aerial and Vicinity Maps