Loading...
Attachment 3 - Project Plans1190 N. EAST STREET CONDITION USE PERMIT APPLICATION PACKAGE Architectural A1.0 - EXISTING SITE PHOTOS A2.0 - ALTA A3.0 - SITE PLAN A4.0 - FLOOR PLAN/ ROOF PLAN/ SECTION A5.0 - ELEVATIONS A5.1 - ELEVATIONS BLACK AND WHITE A6.0 - MATERIAL COLOR BOARD A7.0 - TRASH ENCLOSURE DETAILS Civil 1 - EXISTING OFF-SITE CONDITIONS 2 - CONCEPTUAL GRADING PLAN 3 - CONCEPTUAL UTILITY PLAN 4 - CONCEPTUAL WQMP PLOT PLAN Landscape L0.1 - CONCEPTUAL LANDSCAPE PLAN L1.1- PLANT SCHEDULE EXHIBIT LIST 1190 N. EAST STREET Anaheim, CA 09-26-2023 1202 N. Magnolia Ave. Anaheim, CA 92801 714.687.7230 John Hopkins Contact: John Hopkins 15635 Alton Parkway, Suite 100 Irvine, CA 92618 949.553.1117 www.mcgarchitecture.com Contact: Olga Ruiz 701 N. Parkcenter Dr. Santa Ana, CA 92705 714.560.8200 msilvey@TAIT.com Contact: Michael Silvey 2825 Litchfield Dr. Riverside, CA 92503 951.255.0402 tim@wilsondavisassociates.com Contact: Tim Davis Architect on record Page Winkler MCG Architecture 15635 Alton Parkway, Suite 100 Irvine, CA 92618 949.553.1117 ATTACHMENT NO. 3 71181176EXISTING±5,096 SF BLDGTO BEDEMOLISHEDR20'-0"R2 0 ' - 0 " R 2 0 ' - 0 "R20'-0 "R20 ' -0 "622YORG BIN4YTRASH BIN4YRECYCLE BINR20'-0"R16'-0"R6'-0"45'-0"45'-0"10'-0" L/S SETBACK 32'-0"12'-0"12'-0"16'-0"24'-0"18'-0"24'-0"18'-0"10'-0"12'-0"24'-0"8'-6"Typ.30'-2"22'-8"8'-6"Typ.6'-0"18'-0"18'-0"10'-0"L/SSETBACK10'-6" 8'-6" Typ.2'-0"10'-0"2'-0"10'-0" L/S SETBACK 44'-0"9'-0"8'-0"9'-0"9'-0"8'-0"9'-0"12'-0"(E) TRAFFICSIGNAL LIGHTEXISTING BUILDING(±21,364 SF)(E) MONUMENT SIGN(E) EXISTING DRIVEWAYTO REMAIN(E) EXISTING DRIVEWAYTO REMAIN(E) SIDEWALK(E) SIDEWALK(E) SIDEWALK(E) TRAFFICSIGNAL LIGHTT(N) TRANSFORMER(E) CATCH BASINTO REMAIN(E)CATCH BASINTO REMAINVAN(E) PYLONSIGN TO BEREFACEDPICK-UP WINDOWCLEARANCEHEIGHT BARDIRECTIONALSIGNAGEPRE-MENUBOARDBIKERACKTHANK YOU &EXIT SIGNCONNECT TOEXISTINGSIDEWALKEVEVVANEVEVEVEVEVPAD 11,200 SF1 STORY - 25' HEIGHTT.E.24'-0"29'-9"31'-5"(E) EXISTING DRIVEWAYTO REMAIN25X25 LINE OF SIGHTTRIANGLE25X25 LINE OF SIGHTTRIANGLE2' PARKINGOVERHANG(E) R/W(E) DRIVEWAY TOBE CLOSEDULTIMATE R/W WITH2' DEDICATIONORDER POINT &5-PANEL MEN BOARD7X50 LINE OF SIGHTTRIANGLE(E) R/WULTIMATE R/W WITH2' DEDICATION10'-0"20'-0"27' -7 "WB-12 - Semi-Trailer Intermediate EVLOADING(N) 3' HIGH BLOCKWALL(E) 6' HIGH BLOCK WALL TOBE REDUCED TO 3' HIGH(E) 6' HIGH BLOCKWALL TO REMAIN(N) 3' HIGH BLOCKWALL(E) WALL TO BEDEMOLISHED, Typ.PROPOSEDRAISED MEDIANMODIFY TWO - WAYLEFT TURN FOR ALEFT TURN POCKETAS SHOWN(N) DIRECTIONAL SIGN7X50 LINE OF SIGHTTRIANGLEINSTALLR3-5R SIGNINSTALL PAVEMENTMARKING AS SHOWNN BRIARWOOD STE EAST STREETE ROMNEYA STREETPARCEL 2PARCEL 1NOTE: This information is conceptual in nature and is subject toadjustments pending further verification and Client, Tenant, andGovernmental Agency approvals. No warranties or guaranties ofany kind are given or implied by the Architect.DATE:MCG JOB #:REVISIONSDATE MCG ARCHITECTURE 2022 ALL RIGHTS RESERVEDCNLOCATION MAP1190 N. EAST STREETANAHEIM, CA22.062.05NOT TO SCALEN0SITE PLANSP-06SCALE : 1" = 20'10'20'40'A-3.0LEGEND:ADA PATH OF TRAVEL12.12.2023DELIVERY HOURS:THE DELIVERY CAN BE MADEAT ANY TIME OF THE DAY.THE LOCATION CANACCOMMODATE BOTH 36'AND 48' TRAILERS AND THEHEIGHT WILL BE A MINIMUMOF 15' HIGH. BFPMANAGERSTATIONBARWORKROOMSTORAGED/T WINDOW123ABC12'-6"44'-0"56'-6"28'-6"20'-6"8'-0"WINDOWCANOPY,Typ.POP-OUT,Typ.WALK-UPWINDOWPOP-OUT,Typ.SERVICEDOORWINDOWELEC.CABINET1-123ABC12'-6"44'-0"56'-6"28'-6" 20'-6"8'-0" SLOPE 3/8" PER FT MIN SLOPE 3/8" PER FT MIN ROOF DRAIN ANDOVERFLOW, Typ.ROOFHATCHROOF EQUIP.CANOPYBELOW, Typ.22'-0"T.O.P.23'-0"T.O.P.25'-0"T.O.P.22'-0"T.O.P.20'-0"T.O.P.22'-0"T.O.P.20'-0"T.O.P.LINE OF BRACING20'-0"T.O.P.LINE OF BRACINGCANOPYBELOW, Typ.CANOPYBELOW, Typ.1-FINISH FLR.ELEV. 0'-0" AFFB.O. CANOPYELEV. 10'-0" AFFFUTURE CEILINGT.O. SHEETELEV. 15'-0" AFFAT.O. CORNICEELEV. 20-0" AFFBROOFEQUIPMENTN0PROPOSEDFLOOR & ROOF PLAN AND SECTION (1,200 SF)Scale : 1/8" = 1'-0"4'8'16'NOTE: This information is conceptual in nature and is subject toadjustments pending further verification and Client, Tenant, andGovernmental Agency approvals. No warranties or guaranties ofany kind are given or implied by the Architect.DATE:MCG JOB #:REVISIONSDATE MCG ARCHITECTURE 2022 ALL RIGHTS RESERVEDC1190 N. EAST STREETANAHEIM, CA22.062.05A-4.0FLOOR PLANROOF PLANSECTION 1GENERAL NOTE:Address numbers to be provided flat on the roof of commercial andindustrial properties as follow:a.Painted or constructed in a contrasting color to the roof materials.b.Numbers to be four (4) feet in height and two (2) feet in width.c.Numbers to be spaced 12 to 18-inches apartd.Numbers to consist of 6-inch thick solid lines.07.07.2023 8-22'3C4C1A7B4C2D5E5E23'1B20'25'9-3'-7"3'-9"10-4C6A7B1A22'22'9-ELEC.CABINET2D4C7B1A22'3C1B22'20'25'8-3C5E1A4C23'1B7B22'25'9-FINISHES:WEST ELEVATIONEAST ELEVATIONNORTH ELEVATIONSOUTH ELEVATION1-EXTERIOR CEMENT PLASTER FINISHMETAL CANOPYFOAM FORMED CORNICEALUMINUM STOREFRONTMETAL DOOR, PAINT OT MATCHADJ. WALLPRE-CAST FINISH2-3-4-5-6-7-8-0PROPOSED EXTERIOR ELEVATIONSScale : 1/8" = 1'-0"4'8'16'SIGNAGE BY OTHERSUNDER A SEPARATE PERMITFINISHES:-A"SUPER WHITE”BY: BENJAMIN MOOREHC-76 “DAVENPORT TAN”BY: BENJAMIN MOORE-B-C-D-E996 “ASHEN TAN”BY: BENJAMIN MOOREDARK BRONZE #40BY: KAWNEERWOOD CLADDINGWALL PANEL "BARK"BY: NICHIHANOTE: This information is conceptual in nature and is subject toadjustments pending further verification and Client, Tenant, andGovernmental Agency approvals. No warranties or guaranties ofany kind are given or implied by the Architect.DATE:MCG JOB #:REVISIONSDATE MCG ARCHITECTURE 2022 ALL RIGHTS RESERVEDC1190 N. EAST STREETANAHEIM, CA22.062.05A-5.19-ROOF TOP UNITS10-MENU BOARD 2'-4" x 1'-9", REFER TOTENANT SIGNAGE PACKAGE FORMORE INFORMATION07.07.2023 ROMNEYA DR.EAST STREET BRIARWOOD ST.4OF1Orange County San Luis Obispo Sacramento Riverside Denver Boise Dallas Atlanta 701 North Parkcenter Drive Santa Ana, CA 92705 p: 714.560.8200 www.tait.com Since 1964 ENGINEERING ENVIRONMENTAL BUILDING LANDASSOCIATES& CHECKED: PM DATE: 04/01/2020 DRAWN: CAD1 JOB NO: AB1234X DATE: 07/04/2020NEXISTING OFF-SITE CONDITIONS N. EAST ST.E. ROMNEYA DR.N. BRIARWOOD ST.LA PALMA AVE.N. ROSEMONT ST.E. BELMONT AVE.N. LIBERTY LN.RIVERSIDE FWY CA SR-91PROJECT SITEVICINITY MAPN.T.SSTARBUCKS NORTHGATE GONZALEZ RE, LLC 1190 EAST STREET ANAHEIM, CA1 ROMNEYA DR.EAST STREET BRIARWOOD ST.FF=173.74(FF=173.50)4OF1Orange County San Luis Obispo Sacramento Riverside Denver Boise Dallas Atlanta 701 North Parkcenter Drive Santa Ana, CA 92705 p: 714.560.8200 www.tait.com Since 1964 ENGINEERING ENVIRONMENTAL BUILDING LANDASSOCIATES& CHECKED: PM DATE: 04/01/2020 DRAWN: CAD1 JOB NO: AB1234X DATE: 07/04/2020NN. EAST ST.E. ROMNEYA DR.N. BRIARWOOD ST.LA PALMA AVE.N. ROSEMONT ST.E. BELMONT AVE.N. LIBERTY LN.RIVERSIDE FWY CA SR-91PROJECT SITEVICINITY MAPN.T.SSTARBUCKS NORTHGATE GONZALEZ RE, LLC 1190 EAST STREET ANAHEIM, CAOWNERCIVILARCHITECTGEOTECHNICALASSESSOR'S PARCEL NUMBERBENCHMARKBASIS OF BEARINGS”SHEET INDEXLEGAL DESCRIPTIONFLOOD ZONEUTILITY PURVEYORSABBREVIATIONSAREA SUMMARYLEGENDCONCEPTUAL GRADING PLAN 22 FF=173.70ROMNEYA DR.EAST STREET BRIARWOOD ST.OFOrange County San Luis Obispo Sacramento Riverside Denver Boise Dallas Atlanta 701 North Parkcenter Drive Santa Ana, CA 92705 p: 714.560.8200 www.tait.com Since 1964 ENGINEERING ENVIRONMENTAL BUILDING LANDASSOCIATES& CHECKED: PM DATE: 04/01/2020 DRAWN: CAD1 JOB NO: AB1234X DATE: 07/04/2020 STARBUCKS NORTHGATE GONZALEZ RE, LLC 1190 EAST STREET ANAHEIM, CA4CONCEPTUAL UTILITY PLAN 3 ROMNEYA DR.EAST STREET BRIARWOOD ST.FF=173.70CONCEPTUAL WQMP PLOT PLANN LEGENDPROPERTY LINEPROPOSED UNDERGROUNDINFILTRATION BASINDRAINAGE AREAACREAGEDRAINAGE AREASPROPOSED LANDSCAPEPROPOSED SURFACE FLOW PATHPROPOSED STORM DRAIN FLOW PATHSTARBUCKS NORTHGATE GONZALEZ RE, LLC 1190 EAST STREET ANAHEIM, CA4OF4 Orange County San Luis Obispo Sacramento Riverside Denver Boise Dallas Atlanta 701 North Parkcenter Drive Santa Ana, CA 92705 p: 714.560.8200 www.tait.com Since 1964 ENGINEERING ENVIRONMENTAL BUILDING LANDASSOCIATES& CHECKED: PM DATE: 04/01/2020 DRAWN: CAD1 JOB NO: AB1234X DATE: 07/04/2020ADS CHAMBER DETAIL4X4 MODULAR WETLANDS DETAIL 7118117662CONCRETEAPRONMETAL CANOPYABOVE8" REINFORCEDCONCRETE BLOCKDOUBLE SWINGMETAL GATESCOLUMN, Typ.SERVICEDOOR2YORG BIN4YTRASH BIN4YRECYCLE BINEXISTING BUILDING(±21,364 SF)(E) MONUMENT SIGN(E) EXISTING DRIVEWAYTO REMAIN(E) EXISTING DRIVEWAYTO REMAIN(E) SIDEWALK(E) SIDEWALK(E) SIDEWALKT(N) TRANSFORMER(E)CATCH BASINTO REMAIN(E)CATCH BASINTO REMAINVAN(E) PYLONSIGN TO BEREFACED(N) DIRECTIONAL SIGNPICK-UP WINDOWCLEARANCEHEIGHT BARDIRECTIONALSIGNAGEPRE-MENUBOARDBIKERACKTHANK YOU &EXIT SIGNCONNECT TOEXISTINGSIDEWALKEVEVVANEVEVEVEVEVPAD 11,200 SF1 STORY - 25' HEIGHTT.E.(E) EXISTING DRIVEWAYTO REMAIN7X50 LINE OF SIGHTTRIANGLE25X25 LINE OF SIGHTTRIANGLE25X25 LINE OF SIGHTTRIANGLE2' PARKINGOVERHANG(E) R/W(E) DRIVEWAY TOBE CLOSEDULTIMATE R/W WITH2' DEDICATIONORDER POINT &5-PANEL MEN BOARD7X50 LINE OF SIGHTTRIANGLE(E) R/WULTIMATE R/W WITH2' DEDICATIONWB-12 - Semi-Trailer Intermediate EVLOADING(N) 3' HIGH BLOCKWALL(E) 6' HIGH BLOCK WALL TOBE REDUCED TO 3' HIGH(E) 6' HIGH BLOCKWALL TO REMAIN(N) 3' HIGH BLOCKWALL(E) WALL TO BEDEMOLISHED, Typ.EVERGREEN PERIMETER TREE2424" BOX MIN.CERCIDIUM X `DESERT MUSEUM` / DESERT MUSEUM PALO VERDE15 GAL, LDECIDUOUS SHADE TREE10MIX OF 24" BOX AND 36" BOXPLATANUS X ACERIFOLIA 'BLOODGOOD' / BLOODGOOD LONDON PLANE TREE15 GAL, MEXISTING PALM TREE TO REMAIN2-DECIDUOUS FLOWERING TREE6PRUNUS CERASIFERA 'KRAUTER VESUVIUS' / KRAUTER VESUVIUS PURPLE-LEAF PLUM24"BOX, MBACKGROUND/SCREENING SHRUBS92PROVIDE SPACE FOR PLANTS TO GROW TO MATURITY AND KEEP THEIR NATURALSHAPE.CISTUS X HYBRIDUS / WHITE ROCKROSE5 GAL, LELAEAGNUS PUNGENS / THORNY ELEAGNUS5 GAL., LHESPERALOE PARVIFLORA / RED YUCCA5 GAL., VLWESTRINGIA FRUTICOSA `WYNABBIE GEM` / WYNABBIE GEM COAST ROSEMARY5 GAL., L4` SCREEN HEDGE SHRUBS102PROVIDE SPACE FOR PLANTS TO GROW TO MATURITY AND KEEP THEIR NATURALSHAPE.CISTUS X PURPUREUS / ORCHID ROCKROSE5 GAL, LELAEAGNUS PUNGENS / THORNY ELEAGNUS5 GAL., LHETEROMELES ARBUTIFOLIA / TOYON15 GAL., LWESTRINGIA FRUTICOSA `WYNABBIE GEM` / WYNABBIE GEM COAST ROSEMARY5 GAL., LACCENT SHRUB87AGAVE DESERTI / DESERT AGAVE5 GAL, LAGAVE X 'BLUE GLOW' / BLUE GLOW AGAVE15 GAL., VL, 48" O.C.ALOE STRIATA / CORAL ALOE5 GAL, LORNAMENTAL GRASS68MUHLENBERGIA CAPILLARIS / PINK MUHLY GRASS1 GAL, LSHRUBS & GROUNDCOVERS4,033 SFLANTANA X 'NEW GOLD' / NEW GOLD LANTANA4661 GAL, L36" ocMYOPORUM PARVIFOLIUM / TRAILING MYOPORUM4661 GAL, L36" ocROSMARINUS OFFICINALIS `PROSTRATUS` / DWARF ROSEMARY6711 GAL, L30" ocDROUGHT TOLERANT GROUNDCOVER366 SFPLANT HEIGHT TO BE LIMITED TO 24" HIGH MAX.OENOTHERA SPECIOSA 'SISKIYOU' / MEXICAN EVENING PRIMROSE1 GAL, LNOTE: This information is conceptual in nature and is subject toadjustments pending further verification and Client, Tenant, andGovernmental Agency approvals. No warranties or guaranties ofany kind are given or implied by the Architect.DATE:MCG JOB #:REVISIONSDATE MCG ARCHITECTURE 2022 ALL RIGHTS RESERVEDC1190 N. EAST STREETANAHEIM, CA22.062.05N BRIARWOOD STE EAST STREETE ROMNEYA STREET NLOCATION MAPNOT TO SCALEPh.(951) 353-2436Wilson Davis AssociatesLandscape Architecture2825 Litchfield Dr.Riverside, CA 92503L1.0CERTIFICATION OF LANDSCAPE DESIGNI hereby certify that:(1) I am a professional appropriately licensed in the State of California to provideprofessional landscape design services.(2) The landscape design and water use calculations for the property located at(provide street address or parcel number(s)) were prepared by me or under mysupervision.(3) The landscape design and water use calculations for the identified propertycomply withthe requirements of the City of Anaheim Landscape Water Efficiency Ordinance(Chapter 10.19of Title 10 of Anaheim Municipal Code) and the Guidelines for Implementation ofthe City ofAnaheim Landscape Water Efficiency Ordinance.(4) The information I have provided in this Certificate of Landscape Design is trueandcorrect and is hereby submitted in compliance with the Guidelines forImplementation of theCity of Anaheim Landscape Water Efficiency Ordinance.Print Name DateSignatureLicense NumberAddressTelephone E-mail AddressLandscape Design Professional’s Stamp(If applicable)Tim Davis8/28/23RLA 33532825 Litchfield Dr., Riverside, CA 92503(951) 353-2436tim@wilsondavisassociates.com0feet401" = 20'206080 NOTE: This information is conceptual in nature and is subject toadjustments pending further verification and Client, Tenant, andGovernmental Agency approvals. No warranties or guaranties ofany kind are given or implied by the Architect.DATE:MCG JOB #:REVISIONSDATE MCG ARCHITECTURE 2022 ALL RIGHTS RESERVEDC1190 N. EAST STREETANAHEIM, CA22.062.05Ph.(951) 353-2436Wilson Davis AssociatesLandscape Architecture2825 Litchfield Dr.Riverside, CA 92503L1.1N BRIARWOOD STREET ELEVATION1/8" = 1'-0"EXISTING 6' VINE COVEREDMASONRY WALL TO REMAINNEW 3' MASONRY WALLWITH LOW THORNY PLANTMATERIAL.PROPOSED NEW FOREGROUND THORNYPLANT MATERIAL, HESPERALOEPARVIFOLIA, AGAVE DESERTII AND/ORAGAVE 'BLUE GLOW', SEE PLANTPHOTOS TOP RIGHT ABOVEPROPOSED NEW SCREENTREESEXISTING PALM TREESTREET TREES TO REMAINE. ROMNEYA ST.PROPOSED NEW FOREGROUND THORNYPLANT MATERIAL, AGAVE DESERTIIAND/OR AGAVE 'BLUE GLOW', SEE PLANTPHOTOS TOP RIGHT ABOVE TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date 1 of 27 This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date 7200 143218 House Brad McKay March 23, 2023 April 3, 2023_R1 BK 1190 N East St Tustin, CA 92805 Site Plan Scale: No Scale2 Location Map Scale: No Scale1 N(E) TRAFFIC SIGNAL LIGHT 8 15 14 11 4 12 5 EXISTING B U I L D I N G (±21,364 S F ) (E) MONUMENT SIGN (E) EXISTING DRIVEWAY TO REMAIN (E) EXISTING DRIVEWAY TO REMAIN 69 PARKING S T A L L S L/S (E) SIDEWALK(E) SIDEWALK (E) SIDEWALK 7 1 (E) TRAFFIC SIGNAL LIGHT PAD BLDG 1,200 SF L/S 34 STALLS T (N) TRANSFORMER L/S (E) EXISTING DRIVEWAY TO BE CLOSED (E)CATCH BASIN TO REMAIN (E)CATCH BASIN TO REMAIN EV 18 (E) REFINE PYLON SIGN (N) MONUMENT SIGN 12 6 7 6 3 PICK-UP WINDOW EXISTING ±5,096 SF BLDG TO BE DEMOLISHED L/S L/SL/S CLEARANCE HEIGHT BAR DIRECTIONAL SIGNAGE PRE-MENU BOARD ORDER POINT & 5-PANEL MEN BOARD BIKE RACK THANK YOU & EXIT SIGN 2YORG BIN4YTRASH BIN4YRECYCLE BINTRASHENCLOSUREN BRIARWOOD ST E EAST STREET E ROMNEYA STREETPARCEL 2 PARCEL 1 N CLEARANCEE F H K I, J G A B D N A.3 B A A.1 B.1 A.2 B.2 A.4 B.3 DRIVETHRU DRIVETHRU A B A B CAUTIONVEHICLECROSSING PEDESTRIANCROSSINGAHEAD LM B.4 Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 7200 143218 House Brad McKay March 23, 2023 April 3, 2023_R1 BK 1190 N East St Tustin, CA 92805 2 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date North Elevation Approximate Scale: 1/8" = 1'-0"1 East Elevation Approximate Scale: 1/8" = 1'-0"2 A.1 B.1 A.2 B.2 Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 7200 143218 House Brad McKay March 23, 2023 April 3, 2023_R1 BK 1190 N East St Tustin, CA 92805 3 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date South Elevation Approximate Scale: 1/8" = 1'-0"1 West Elevation Approximate Scale: 1/8" = 1'-0"2 B.4 A.4 A.3 B.3 Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 4 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date A B C D E F G Sign must be approved by the National Electrical Code, Underwriters Laboratory, CUL, and all applicable local codes. Disconnect switch in primary to be within sight of sign (sign includes power supply enclosure) REF: NEC 110-3[B] 600-2, 600-4 Primary electrical source (1/2"(13mm) conduit minimum) REF: NEC 600- 6, 600-21(provided by installer). Manufacture and install four (4) illuminated wall mounted flex face logo disk. A.1, A.2, A.3 & A.4 13164 - SIGN DISK SF ILL FLSH 60IN Excellart EC-Flex Standard with Bleed Trim Cover. Paint interior reflective white and paint 4 1/2" return satin black. Face to be white flexible material. Face retention clips at 4" o.c.. Siren graphic to be reversed out white from 3M Dk. Emerald Green 3630-126 vinyl film background. Internally illuminate logo disk with 6500K white Sloan Prism Enlighten LEDs. LEDs to be mounted to .063" aluminum baffle with 1" spacers (paint reflective white). Remote Sloan 60W/12VDC power supplies, 60W3 (wet Locations). Mount logo disk to wall with 7/16” Nutserts. Side Section View Scale: 1 1/2" = 1'-0"4 Excellart EC-Flex Standard with Bleed Trim Cover Detail Scale 1:2 (half full size)5 Booted toggle switch on box Metal power supply enclosure Location varies (T.B.D.) Electrical to power supply in flexible conduit (by installer) Sloan power supply 60W3 7/16” Nutsert(s) White flex face material Incoming primary power F G B D A Front View Scale: 1/2" = 1'-0"1Side View Scale: 1/2" = 1'-0"2 Front Section View Detail Scale: 1/2" = 1'-0"3 C B #6 Pan Head Screw .125" aluminum back 4 1/2" 3 5/8"7/8" A Excellart EC-Flex Standard with Bleed Trim Cover 6500k white Sloan Prism Enlighten LEDs E .063" aluminum baffle mounted to 1" spacers 5 AN HEAD SCREWS Excellart face retention clips spaced at 4" o.c.5'-0"5'-0"4 1/2" Matthews Black Satin finish. White flex fabric Sloan Prism Enlighten White 6500k3630-126 3M Dark Emerald vinyl film Removable fasteners for service access Aluminum channel painted satin black. A Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 April 3, 2023_R1 BK 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 5 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date Front View Scale: 1" = 1'-0"1Side View Scale: 1" = 1'-0"2 LED Detail Scale:1" = 1'-0"3 B.1, B.2 & B.4 CUSTOM DAY/NITE “DRIVE THRU” Letterset (Flush) A B C D E F Sign must be approved by the National Electrical Code, Underwriters Laboratory, CUL, and all applicable local codes. Disconnect switch in primary to be within sight of sign (sign includes power supply enclosure) REF: NEC 110-3[B] 600-2, 600-4 Primary electrical source (1/2"(13mm) conduit minimum) REF: NEC 600- 6, 600-21(provided by installer). Manufacture and install three (3) illuminated flush mount DRIVE THRU lettersets. Internally illuminated SDS LetterForm trimless channel letter with returns painted satin black. White faces to be 1/4" 7328 matte white acrylic. Overlay with 3M Dual Color Film 3635-22 Black (or similar). Internally illuminated letters with 6500K White Sloan Prism Enlighten LEDs. Remote Sloan 60W/12VDC power supplies, 60C2 (damp/dry locations) or 60W3 (wet Locations). 1/4" drain holes located at the bottom of each letter as required by UL 48 for Electric Signs. Drain holes to be covered with .040" aluminum hat channel covers to reduce light leaks. Peg mount letters 1/2" from wall with threaded rod (through bolt) and Black spacers. Side Section View Scale: NTS4 Side Section View Detail Scale: NTS5 5 Side Section View Detail Scale: NTS6 6 2 3/8" 2 1/2" 1/8" 1/2" Booted toggle switch on box Metal power supply enclosure Location varies (T.B.D.) Electrical to power supply in flexible conduit (by installer) Sloan power supply 60C2 or 60W3 Threaded rod (through bolt) 1/2" Black spacer stand-offs 1/2" black spacer stand-offs 1/4" Composite back 1/4" drain holes in letter low points with .040" aluminum hat channel covers Incoming primary power Removable fasteners for service access Aluminum channel painted satin black. 1/4" 1/8"1/8" 6500k white Sloan Prism Enlighten LEDs Structural adhesive Attach EasyClip to back with pop rivets A D F E B C 1/4" thick 7328 matte white acrylic Matthews Black Satin finish. 3M 3635-22 Black Dual Color Film (or similar) 1/4" White #7328 acrylic Matte finish Sloan Prism Enlighten White 6500k 2 1/2" 1/2" LED Path TBD8"5'-6" Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 April 3, 2023_R1 BK 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 6 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date Front View Scale: 1" = 1'-0"1Side View Scale: 1" = 1'-0"2 LED Detail Scale:1" = 1'-0"3 B.3 CUSTOM “DRIVE THRU” Letterset (Flush Mount) A B C D E F Sign must be approved by the National Electrical Code, Underwriters Laboratory, CUL, and all applicable local codes. Disconnect switch in primary to be within sight of sign (sign includes power supply enclosure) REF: NEC 110-3[B] 600-2, 600-4 Primary electrical source (1/2"(13mm) conduit minimum) REF: NEC 600- 6, 600-21(provided by installer). Manufacture and install one (1) illuminated flush mount DRIVE THRU letterset. Internally illuminated SDS LetterForm trimless channel letter with returns painted satin black. White faces to be 1/4" 7328 matte white acrylic. Internally illuminated letters with 6500K White Sloan Prism Enlighten LEDs. Remote Sloan 60W/12VDC power supplies, 60C2 (damp/dry locations) or 60W3 (wet Locations). 1/4" drain holes located at the bottom of each letter as required by UL 48 for Electric Signs. Drain holes to be covered with .040" aluminum hat channel covers to reduce light leaks. Peg mount letters 1/2" from wall with threaded rod (through bolt) and Black spacers. Side Section View Scale: NTS4 Side Section View Detail Scale: NTS5 5 Side Section View Detail Scale: NTS6 6 2 3/8" 2 1/2" 1/8" 1/2" Booted toggle switch on box Metal power supply enclosure Location varies (T.B.D.) Electrical to power supply in flexible conduit (by installer) Sloan power supply 60C2 or 60W3 Threaded rod (through bolt) 1/2" Black spacer stand-offs 1/2" black spacer stand-offs 1/4" Composite back 1/4" drain holes in letter low points with .040" aluminum hat channel covers Incoming primary power Removable fasteners for service access Aluminum channel painted satin black. 1/4" 1/8"1/8" 6500k white Sloan Prism Enlighten LEDs Structural adhesive Attach EasyClip to back with pop rivets A D F E B C 1/4" thick 7328 matte white acrylic Matthews Black Satin finish. 1/4" White #7328 acrylic Matte finish Sloan Prism Enlighten White 6500k 2 1/2" 1/2" LED Path TBD8"5'-6" Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 7 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date Front View Scale: 1/2" = 1'-0"1Side View Scale: 1/2" = 1'-0"2 LED Detail Scale:1/2" = 1'-0"3 A B C D E F Sign must be approved by the National Electrical Code, Underwriters Laboratory, CUL, and all applicable local codes. Disconnect switch in primary to be within sight of sign (sign includes power supply enclosure) REF: NEC 110-3[B] 600-2, 600-4 Primary electrical source (1/2"(13mm) conduit minimum) REF: NEC 600- 6, 600-21(provided by installer). Manufacture and install one (1) set of individually illuminated channel letters peg mounted 1/2" from wall. C.1 CUSTOM SIGN WMARK SBUX FSH MT 14IN GN Internally illuminated SDS LetterForm trimless channel letter with returns painted satin black. Green faces to be 1/4" 7328 gloss white acrylic with 3M 3630-126 Dark Emerald Green vinyl applied first surface. Internally illuminated letters with 6500K White Sloan Prism Enlighten LEDs. Remote Sloan 60W/12VDC power supplies, 60C2 (damp/dry locations) or 60W3 (wet Locations). 1/4" drain holes located at the bottom of each letter as required by UL 48 for Electric Signs. Drain holes to be covered with .040" aluminum hat channel covers to reduce light leaks. Peg mount letters 1/2" from wall with threaded rod (through bolt) and Black spacers.1'-2"11'-10 5/8" LED Path TBD Side Section View Scale: NTS4 Side Section View Detail Scale: NTS5 5 Side Section View Detail Scale: NTS6 6 2 3/8"1/8" 1/2" Booted toggle switch on box Metal power supply enclosure Location varies (T.B.D.) Electrical to power supply in flexible conduit (by installer) Sloan power supply 60C2 or 60W3 Threaded rod (through bolt) 1/2" Black spacer stand-offs 1/2" black spacer stand-offs 1/4" Composite back 1/4" drain holes in letter low points with .040" aluminum hat channel covers Incoming primary power 1/4" 1/8"1/8" 6500k white Sloan Prism Enlighten LEDs Structural adhesive Attach EasyClip to back with pop rivets D F E B C 1/4" thick 7328 matte white acrylic 2 1/2" 1/2" Matthews Black Satin finish. 1/4" White #7328 acrylic Gloss finish Sloan Prism Enlighten White 6500k3630-126 3M Dark Emerald vinyl film 2 1/2" Removable fasteners for service access Aluminum channel painted satin black. A Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 8 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date Aluminum PMS 560 C PMS 419 C Black Red vinyl (TBD) Steel Clear Acrylic 3M White Translucent vinyl 3M Diffuser film Manufacture and install one (1) illuminated 44” exit only/thank you sign. D - 23074 - 44” EXIT ONLY/THANK YOU SIGN Front View (SIDE A - "THANK YOU!") Scale: 1" = 1'-0"1 Front View (SIDE B - "EXIT ONLY") Scale: 1" = 1'-0"3End View Scale: 1" = 1'-0"2 Page 1 of 3 Renderings Scale: NTS4 1-1/2" exposed concrete base (2'-0" dia.) Sonotube footer with top portion removed to expose concrete. Anchor bolts. 24" dia typical. A B C D E F G H I J 2" x 8" aluminum welded rec tube cabinet with fabricated aluminum faces painted to match PMS 560 C. Frame painted to match PMS 419 C Black (all satin finish). .125" routed aluminum faces with top flanges (1/2" oversize on both sides) 3/8" Clear Acrylic net-push thru “X,” “EXIT ONLY” and “THANK YOU !” graphics. 3M White translucent vinyl applied to face & 3M Diffuser applied to second surface. “X” to have additional red vinyl applied to first surface (Color TBD). Removable faces to shoebox over cabinet. Vertical internal aluminum angles welded to face interiors to affix faces to cabinet sides with countersunk screws (painted to match cabinet). Additional countersunk fasteners at top of cabinet (painted to match faces). LED ACM (Sloan Prism Enlighten 6500k LEDs) baffle to be attached with self tapping tech screws into aluminum angles. Internal powersupply with disconnect switch recessed into frame. TBD TBD TBD TBD TBD MOUNTING SPECS & LED PATH TO BE DETERMINED BY PRODUCTION TEAM. 3'-8"1 1/2"2 5/16"3 1/16"1'-8"9 15/16"4" 2'-0"3 3/8"3 3/16"3 3/8"2 3/8"3 3/8"Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 9 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date D- 23074 - 44” EXIT ONLY/THANK YOU SIGN (COMPONENTS) Page 2 of 3 Exploded Components Scale: NTS2Component List Scale: NTS1 Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 10 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date Components - Face & Frame Approximate Scale: 3/4" = 1'-0"3Components - Structure Approximate Scale: 1-1/2" = 1'-0"2 Footing Details Scale: NTS1 COMPONENT NUMBERS HIGHLIGHTED IN YELLOW REFER TO LIST ON PAGE 2 OF 3. D - 23074 - 44” EXIT ONLY/THANK YOU SIGN (COMPONENTS) Page 3 of 3 Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 July 11, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 11 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date Aluminum PMS 560 C PMS 3425 CPMS 419 C Black Steel Clear Acrylic 3M White Translucent vinyl 3M Diffuser film Manufacture and install one (1) illuminated 44” drive thru directional signs. E - 44" DRIVE THRU Front View (SIDE A) Scale: 1" = 1'-0"1 Front View (SIDE B) Scale: 1" = 1'-0"3End View Scale: 1" = 1'-0"2 Page 1 of 3 Renderings Scale: NTS4 1-1/2" exposed concrete base (2'-0" dia.) Sonotube footer with top portion removed to expose concrete. Anchor bolts. 24" dia typical. A B C D E F G H I J 2" x 8" aluminum welded rec tube cabinet with fabricated aluminum faces painted to match PMS 560 C. Frame painted to match PMS 419 C Black (all satin finish). .125" routed aluminum faces with top flanges (1/2" oversize on both sides) 3/8" Clear Acrylic net-push “DRIVE THRU” & "Welcome" graphics. 3M White translucent vinyl applied to face & 3M Diffuser applied to second surface. Siren logo to have digital print translucent vinyl to match PMS 3425 C applied first surface. Removable faces to shoebox over cabinet. Vertical internal aluminum angles welded to face interiors to affix faces to cabinet sides with countersunk screws (painted to match cabinet). Additional countersunk fasteners at top of cabinet (painted to match faces). LED ACM (Sloan Prism Enlighten 6500k LEDs) baffle to be attached with self tapping tech screws into aluminum angles. Internal powersupply with disconnect switch recessed into frame. TBD TBD TBD TBD TBD MOUNTING SPECS & LED PATH TO BE DETERMINED BY PRODUCTION TEAM. 3'-8"1 1/2"1'-8"4" 2'-0"2 1/8"9"1 7/8"2 3/8"3 3/8"3 5/16"Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 1 3/4" 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 12 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date E - 44" DRIVE THRU Page 2 of 3 Exploded Components Scale: NTS2Component List Scale: NTS1 NOTE: FACE GRAPHICS TO BE ADDED TO PARTS ONCE DESIGN IS FINALIZED. Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 13 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date Components - Face & Frame Approximate Scale: 3/4" = 1'-0"3Components - Structure Approximate Scale: 1-1/2" = 1'-0"2 Footing Details Scale: NTS1 COMPONENT NUMBERS HIGHLIGHTED IN YELLOW REFER TO LIST ON PAGE 2 OF 3. E - 44" DRIVE THRU Page 3 of 3 NOTE: FACE GRAPHICS TO BE ADDED TO PARTS ONCE DESIGN IS FINALIZED. Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 14 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date AA B C Scraper Bar to be 2"(51mm) x steel rectangular tube, ends , painted Green to match PMS 560c (satin finish). Suspend sign face from suppor NOTE: Cables length provided to accommodate a clearance height as low as a 7'-0", along with a sheet of clearance heights ranging from 7'-0" to the maximum height of 9'-0". (Sign installer to confirm and apply height restriction in the field during the installation of the clearance bar) t arm with 3/16" s.s. cable and attachment hardware. Suppor t structure to be welded steel square tube construction with swivel plate assembly, Powder coated PSB6865 Blackboard. Support structure be constructed as per approved shop drawings. All foundations, existing and new must be analyzed for suitability and must meet local city and state code regulations. 5"(127mm) x 3/16"(5mm) to be flush capped with aluminum Copy to be opaque 3M Scotchlite White #680-10 reflective film (field apply). 4'(73mm) x 4"(102mm) x 1/4"(8mm) D Base cover to be .090" aluminum with aluminum heavy-duty rivet nut fasteners. Powder coated PSB6865 Blackboard. E For footing see following pages.F F - Design ID #22544 Manufacture and install one (1) single faced non-illuminated drive thru clearance bar sign. Front View Scale: 1/2" = 1'-0"1 Plan View Scale: 1/2" = 1'-0"3 5 1/2"1'-0 1/2" Section View Scale: 3" = 1'-0"4 Welded Tab Section View Half Scale54" (102mm)4" x 4" x 1/4"(73mm x 102mm x 6.35mm) steel tube cross bar horizontal tube Type 304 S.S. Thimble for 3/16" wire rope Typ. (do not paint) Type 304 SS oval compression sleeve 3/16"(5mm) dia. type 316 SS wire rope (7 x 19 strand core) 3/16" Tab to Tube 3/16" Tab to Tube 3/16" (5mm) type 316 SSwire rope clip. (2) SS nylon locknuts per clip Type 304 S.S. Thimble for 3/16" wire rope Typ. (do not paint) 3/8" Thick Steel mounting TAB - Weld to TOP of Placard ( 2 REQ’D ) paint to match tube. 3/8" Thick Steel mounting TAB - Weld to TOP of Placard ( 2 REQ’D ) Paint to match tube / cross bar. 2" x 5" x 3/16"(51mm x 127mm x 5mm) steel rectangular tube placard.Varies5" (127mm)3 3/4" (95mm) req. turnback1 1/2"1 1/2"3/4"1 1/2"Ø 3/4" 3/8" Placard Graphic Details- Front View Scale: 1" = 1'-0"75"(127mm)(82mm) 5'-6"(1676mm) 3'-6" (1067mm) Painted green to match PMS 560c (satin finish) Copy to be opaque 3M Scotchlite White #680-10 reflective film AA AB 3'-6" (1067mm) o.c. 5" (127mm) 9'-0" (2743mm) 5'-6" (1676mm)3'-2" (965mm)4" (102mm)10'-3" (3124mm) 4" x 4" x 1/4"(73mm x 102mm x 6.35mm) steel tube painted black to match RAL 7021M 8'-6" (2591mm) NOTE: Clearance Bar height may require adjustment to accommodate curb and/or foundation height. Manufacture to provide (2) 2'-6" (762mm) cable lengths for such adjustments. 90˚ Can rotate up to 90˚ if struck by vehicle 4" (102mm) 4" (102mm) Side View Scale: 1/2" = 1'-0"2 CLEARANCE 8'6" CLEARANCE 8'6"3 1/4"AE AAAD DT Clearance Legend Scale: 1" = 1'-0" 10'-3" (3124mm) Sq. Ft.Size 2.29 1-7'-0" 2- 8'-0"1- 1- 8'-6"2- 9'-0" Imperial Metric Included Extra Pre-Space Legend 1.) Figured as visual text DT Clearance Bar Freestanding - 10'-3" 3124mm #22544 7'-6" 2.13m 2.28m 2.44m 2.59m 2.74m 7'0" 7'6" 8'0" 8'6" 9'0" 3 1/4"Base Plate Enlarged Detail Scale: 1 1/2" = 1'-0"6 1'-0"1'-0"3 15/16"4 1/8"3 15/16"3 15/16"4 1/8"3 15/16" 4X R 1/2" 4X 1/2" X 45˚ 8X R 1/2" 8" O.C.8" O.C.3/4" (19mm) Steel base Plate Drain hole at baseplate center 2"2"2"2"4" x 4" x 1/4"(73mm x 102mm x 6.35mm) steel tube vertical tube 1/4"Top and bottom Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 15 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date 2X Ø 17/32" Thru 1 17/32" Thru 4X R 1 7/16" Bottom Swivel Plate Detail Scale: 3"=1'-0"5 Swivel Rod Detail Scale: 3"=1'-0"7 Swivel Plate Assembly Detail Scale: 3"=1'-0"8 Swivel Plate 3D View Scale: 3"=1'-0"9 Pivot Stop Detail Scale: 1:2 (half size)6Top Swivel Plate Detail Scale: 3"=1'-0"4 18-8 Stainless steel SAE washer, black oxide finish, 1 1/2" screw size. 1 5/8" ID, 3" OD Black Oxide 18-8 Stainless steel washer, oversized, 1" screw size, 1.062” ID, 3” OD Bottom support structure Top support structure 3 13/16" 31/32"31/32"3 13/16"1/4" 3 13/16" Ø 2.65 1 7/8" 4X R 1 7/16" 8X R 5/16"3 13/16"CL CL CL 1 7/8"31/32"31/32"1 7/8"CL 1 17/32"1/4" 1/4" Steel Plate 1/4" Steel Plate5/8"Swivel Rod Pivot Stops Bottom Swivel Plate7"Ø 7/8" 1-8 UNC 2 1/2" Ø 1 1/2"1 1/2" 1 1/2" 3/4"3/4"2 1/2"Section A-AA A 2"1/2" 1/2"1/2"6 3/4"7"1/4"2"1 1/2" 3 13/16" Weld 1/4" from bottom of plate10'-3 1/4"9'-7 3/4"3/4"1/4"9'-8 1/2"9'-8 1/4"6 3/4"1/4" 1/4"Top and bottom G Bottom Support Structure Detail Scale: 1/2"=1'-0"2 Clearance Bar 3D View Scale: Approx. 1/2"=1'-0"3 Top Support Structure Detail Scale: 1/2"=1'-0"1 9'-0"6"1/4"Top Swivel Plate End Cap Swivel Plate Assembly 4" x 4" x 1/4"(73mm x 102mm x 6.35mm) steel tube cross bar horizontal tube 1/4"G 1/4"G 1/4"G 3/8" Thick Steel mounting TAB Front Base Cover Back Base Cover Placard 3/16"(5mm) dia. type 316 SS wire rope(7 x 19 strand core) 1 2 7 6 5 Zinc yellow-chromate plated hex head screw, SAE Grade 8 Steel (Fu = 150 ksi), 1"-8 thread size, 2 1/2" long 1/4"G BOLT TO HAVE MINIMUM TORQUE OF 1175 FT-LBS Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 16 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date1'-0 1/2"4 3/16"4 1/8"4 3/16" 1'-0 1/2" 1'-0 1/2"8 5/16"R 1/2"5 1/2"5 1/2"5/8"5/8" 2"2" 3/8"1 1/4"3/8"4 7/8"1'-0 1/2"5 1/8"4X Ø 1 17/64" Thru 5/8"Front Base Cover Plan View Detail Scale: 1 1/2"=1'-0"1 Front Base Cover Front View Detail Scale: 1 1/2"=1'-0"2 Front Base Cover Back View Detail Scale: 1 1/2"=1'-0"3 Back Base Cover Plan View Detail Scale: 1 1/2"=1'-0"5 Back Base Cover Front View Detail Scale: 1 1/2"=1'-0"4 Back Base Cover Side View Detail Scale: 1 1/2"=1'-0"6 Front Base Cover 3D View Scale: NTS7 Base Cover 3D View Scale: NTS84 9/32"1'-0 1/4" 4 3/32"4 1/16"4 3/32"5 3/8"5 1/2"5 1/2"4 9/32" 1'-0 1/4" 1/4"1/4"1/4" 1 7/8"1 7/8" 12"1 1/4"2X R 1/8" 4X Ø 3/16" Thru5 1/8"Aluminum heavy-duty rivet nut fasteners. Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 17 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date Footing Details Scale: NTS1 (4) 3/4" DIA. GALVANIZED ANCHOR BOLTS MIN. 1' - 9" 6" AVG. ROAD BEDCURB AND GRADE MAY VARY PER LOCATION NON-STRUCTURAL BASE COVER BASE PLATE (4) #4 VERTICAL BARS SPACED EVENLY AROUND PERIMETER DIA.1 1/2"(3) #3 TIES WITHIN FIRST 5" THEN #3 TIES AT 9" O.C..3" CLR.25" MIN.3" CLR. POST-INSTALLED ANCHORS NOT PERMITTED DUE TO CLOSE SPACING OF ANCHOR BOLTS 2' - 0"(150 : 5' -3")GREATER OF 4' - 3" ORLOCAL FROST DEPTHFOOTING SUBJECT TO FINAL ENGINEERING. ABOVE DRAWING FOR REPRESENTATIONAL PURPOSES ONLY. Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 18 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date SIGN G - Design ID #22542 PRE MENU BOARD Manufactured by others, installed by TubeArt 29 116 " 22 14 " 5 12 " 13.95 41 38 " 1 5 7 8.73 60.82 12 2732 " 5 3D VIEWFOR REFERENCE ONLY 4 LARGE POST WIRING CONNECTIOM PLATEHIDDEN UNDER BASE COVER 2 NOTE: ITEM 3, 4, & 6 NOT VISIBLE ITEM NO.QTY.FINISHDESCRIPTION# TRAP 1 1 8 1 1 1 1 1 NTS NTS Ground Footing Base Plate Anchor Rod NTSAnchor Bolt Pattern NTS NTS 8 3/4" SIDE ELEVATIONFRONT ELEVATION DIA. 2' - 0" 2' - 5 1/8" DIA. 2' - 0" NON-STRUCTURALBASE COVER HOT DIPPED GALVANIZED LEVELING NUTS (4) REQUIRED STEEL MOUNTING BASE WELDED TO POST NATURAL GRADE OR ENGINEERED FILL (4) 3/4" DIA. X 9" LONG GALVANIZED ANCHOR BOLTS; 3 1/4" PROJECTION ABOVE FOOTING (3) #3 TIES W ITHIN FIRST 5" THEN #3 TIES AT 12" O.C. (6) #5 VERTICAL BAR SPACED EVENLY AROUND PERIMETER 6" MIN. CONDUIT.1 1/2"GREATER OF 3' - 9" ORLOCAL FROST DEPTH3" MIN.3" MIN.1' - 7 1/2"3' - 5 3/8"(150 : 4' -8")TACK NUT TO ROD 1/2" HEAVY HEX NUT WITH WASHER (4) 1/2" DIA. X 9" LENGTH A36 THREADED HOT DIPPED GALVANIZED ANCHOR RODS WITH GALVANIZED HARDWARE (3) 1/2" -13 HEAVY HEX NUTS & WASHER -GALVANIZED ROD LENGTH = SEE ELEVATION CENTER ANCHOR ROD PATTERN IN FOUNDATION ALTERNATE ADHESIVE POST-INSTALLED ANCHORS:HILTI 1/2" DIA. HVU ADHESIVE CAPSULES AT 4" EMBEDMENT WITH A36 HOT-DIPPED GALVANIZED THREADED STEEL RODS AND HARDWARE. (4) REQUIRED 4 1/2"4"4"4 1/2" 1' - 5"2"4"4"2"1' - 0"FRONT EDGE FACING DRIVE THRU LANE 3/4" STEEL BASE PLATE THRU HOLE FOR MOUNTING (TYP.) 2 1/2" SQUAREX 1/4" PLATE WASHER (TYP. 1 OF 4) 6 1/2"4"6 1/2" ANCHOR BOLT (TYP 1 OF 4) 6" X 3" X 0.1875" STEEL POST WELDED TO BASE PLATE 2' - 0" DIA. 8"8"8" 4"4"8"8"8"ALL ANCHORS TO BE PROVIDED BY G.C. CONDUIT STUB-UP 3" ABOVE FOOTING ANCHOR BOLT (TYP. 1 OF 4) BASEOUTLINE DRIVE LANE FACE THIS SIDE 4"4"DIMENSIONS IN RED ARE FOR 150 MPH WIND LOAD Footings may vary due to site specific soil conditions and frost penetration. The information provided on the pole and sign footings herein are subject to approval by the City and/or Municipality. Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 19 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date SIGN H - Design ID #22540 5 PANEL MENU BOARD Manufactured by others, installed by TubeArt FRONT ELEVATION NON-STRUCTURALBASE COVER HOT DIPPED GALVANIZED LEVELING NUTS (4) REQUIRED STEEL MOUNTING BASE PLATE WELDED TO STEEL POST SIDE ELEVATION NATURAL GRADE OR ENGINEERED FILL (4) 3/4" DIA. X 14" LONG GALVANIZED ANCHOR BOLTS; 4" PROJECTION ABOVE FOOTING (3) #3 TIES WITHIN FIRST 5" THEN #3 TIES AT 12" O.C. (8) #6 VERTICAL BAR SPACED EVENLY AROUND PERIMETERDIA. 2' - 6" DIA. 2' - 6"GREATER OF 5' - 0" ORLOCAL FROST DEPTH1 1/2"3" MIN.3" MIN.8" MIN..CONDUIT3' - 6 3/4"1' - 6 3/4"7' - 10 1/2"1' - 1 1/2" NTS NTS NTS NTS Ground Footing Base Plate Anchor Rod NTSAnchor Bolt Pattern SEE DETAIL 1 ON SHEET 3 FOR ANCHOR ROD PATTERN IN FOUNDATION ALTERNATE ADHESIVE POST-INSTALLED ANCHORS:HILTI 3/4" DIA. HVU ADHESIVE CAPSULES AT 8" EMBEDMENT WITH A36 HOT-DIPPED GALVANIZED THREADED STEEL RODS AND HARDWARE.(4) REQUIREDTACK NUT TO ROD 3/4" HEAVY HEX NUT WITH WASHER (4) 3/4" DIA. A36 THREAD ED HOT DIPPED GALVANIZED ANCHOR RODS WITH GALVANIZED HARDWARE (3) 3/4" HEAVY HEX NUTS & WASHER -GALVANIZED ROD LENGTH = SEE ELEVATION 8" X 4" X 0.1875" STEEL TUBEPOST WELDED TO BASE PLATE 3"8"3"1' - 6" 7"4"7"7"7"1' - 2"THRU HOLE FOR MOUNTING(TYP.) 2 1/2" SQUARE X 1/4" PLATE WASHER (TYP. 1 OF 4)) 3/4" STEEL BASE PLATE FRONT EDGE FACING DRIVE THRU LANE 2"5"5"2"2"2" 5"2"4"2"5" ANCHOR BOLT (TYP 1 OF 4) ALL ANCHORS TO BE PROVIDED BY G.C. CONDUIT STUB-UP 3" ABOVE FOOTING (4) ANCHORBOLTS BASE PLATEOUTLINE FRONT EDGE OF DRIVE LANE SIDE 11"8"11"4"4"11"8"11"1' - 3"1' - 3" 2' - 6" DIA. Footings may vary due to site specific soil conditions and frost penetration. The information provided on the pole and sign footings herein are subject to approval by the City and/or Municipality. Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 20 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date 235 4 1 6 ITEM 7HIDDEN INBASE COVER C SIGN I - Design ID #22543 ORDER POINT CANOPY Manufactured by others, installed by TubeArt 54" 64" 45 34 " 123 78 " 15.43 5 12 " 96.93 4" 4" 8" 8" 8" 50 " 8" 8" 8" 20 78 " DRIVE THRU CURB HERE OFFSET DOSANCHOR CAGE ITEM NO..YTQFINISHDESCRIPTION# TRAP Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 21 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date SIGN J - Design ID #22546 DIGITAL ORDER SYSTEM & POST Manufactured by others, installed by TubeArt Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 22 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date NON-STRUCTURALBASE COVER FRONT ELEVATION SIDE ELEVATION HOT DIPPED GALVANIZED LEVELING NUTS (4) REQUIRED STEEL MOUNTING BASE W ELDED TO POST NATURAL GRADE OR ENGINEERED FILL DIA. 2' - 0" (4) 3/4" DIA. X 9" LONG GALVANIZED ANCHOR BOLTS; 3 1/4" PROJECTION ABOVE FOOTING (3) #3 TIES WITHIN FIRST 5" THEN #3 TIES AT 12" O.C. (6) #5 VERTICAL BAR SPACED EVENLY AROUND PERIMETERGREATER OF 3' - 9" ORLOCAL FROST DEPTH1 1/2"DIA. 2' - 0"3" CLR.3" CLR..6" MIN. CONDUIT4' - 1 3/4"1' - 9 3/4"2' - 5 1/4"8 1/4"9 3/8"(150 : 4' -8")DIMENSIONS IN RED ARE FOR 150 MPH WIND LOADNTS NTSGround Footing TACK NUT TO ROD 3/4" HEAVY HEX NUT WITH WASHER (4) 3/4" DIA. X 9" LENGTH A36 THREADED HOT DIPPED GALVANIZED ANCHOR RODS WITH GALVANIZED HARDWARE (3) 3/4" -13 HEAVY HEX NUTS & WASHER -GALVANIZED ROD LENGTH = SEE ELEVATION CENTER ANCHOR ROD PATTERN IN FOUNDATION ALTERNATE ADHESIVE POST-INSTALLED ANCHORS:HILTI 3/4" DIA. HVU ADHESIVE CAPSULES AT 4" EMBEDMENT WITH A36 HOT-DIPPED GALVANIZED THREADED STEEL RODS AND HARDWARE. (4) REQUIRED NTSAnchor Rod NTSBase Plate 0.625" STEEL BASE PLATE 1' - 2 1/4" 3 1/8"EQ EQ 3 1/8"2 1/4"2 1/4"EQEQ1' - 0 1/2"THRU HOLES FOR MOUNTING (TYP.) 9.843" X 3.973 X 3/16" STEEL POST W ELDED TO STEEL BASE PLATE FRONT EDGE FACING DT LANE 2 1/2" SQUAREX 1/4" PLATE W ASHERS (TYP. 1 OF 4) ANCHOR BOLT (TYP 1 OF 4) NTSAnchor Bolt Pattern 115 MPH WIND LOAD RISK CATEGORY II, EXPOSURE C ESTIMATED COMBINED WEIGHT OF POST & DOS: 391 LBS CONCRETE STRENGTH: MIN. 3000 PSI @ 28 DAYS 2012 INTERNATIONAL BUILDING CODE, ASCE 7-10 LATERAL SOIL BEARING PRESSURE: 200 PSF DESIGN LOADS ASSUMED CONDITIONS (150 MPH WIND LOAD) ALL ANCHORS TO BE PROVIDED BY G.C. (4) ANCHORBOLTS BASE OUTLINE DRIVE THRU LANE FACE THIS SIDE CONDUIT STUB-UPS 3" ABOVE FOOTING DETECTOR LOOP STUB-UPDRIVE THRU POS STUB-UPDRIVE THRU POS STUB-UPELECTRICAL STUB-UP2' - 0" DIA. 8"4"4"8"8"4"4"8"2"1"1"2" G.C. RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY. ROUTE CONDUIT PER ELECTRICAL SITE PLAN PROVIDE 3" STUB-UP ROTATE FOOTING BOLT PATTERN RELATIVE TO DRIVE LANE PER SITE PLAN AND SIGNAGE CONFIGURATION DETAILS Footings may vary due to site specific soil conditions and frost penetration. The information provided on the pole and sign footings herein are subject to approval by the City and/or Municipality. Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 23 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date Side View - DT Order Point Canopy Scale: 3/8" = 1'-0"1 Front View - DT Order Point Canopy Scale: 3/8" = 1'-0"25'-11"2° 3 1/4"9'-2 1/2"5'-10 1/2" 4'-7 5/8"#9 -Base Covers Footings may vary due to site specific soil conditions and frost penetration. The information provided on the pole and sign footings herein are subject to approval by the City and/or Municipality. #3 -Header Channel #7 -Steel Frame #2 -Steel Posts #11 -LED Floodlight #10 -Electric Enclosure 3'-3 3/4" 2'-2 3/4"#3 -Roof Panels #5 -Roof Frame #3 -Header Channel 4'-6"9'-9 5/8"2'-6" Diameter Undisturbed soil (6) # 5 bars #3 ties, 10" c/c (3 in top 5 inches) Concrete foundation Heavy hex nut 1/4" plate, 3" x 3" 3/4" diameter, 36” length A307 anchor bolts #8 -Acrylic Letters #7 -Steel Frame #6 - #11 #7 -3'-5" to center adjustable 37" to 45"9 5/8"3'-8 3/8" monitor space13/16" monitor set back #9 -Base covers 4'-5 1/2" O.A. 1'-4" typ. 4'-0 1/8" Roof 1. 3/4” Anchor bolts 2. Galvanized 3. 4” of AB’s exposed vers vers 54" 81" 123 78 " 4" X 4" PO 7.43 96.93 Side View - DT Order Point Canopy Scale: 3/8" = 1'-0"1 Front View - DT Order Point Canopy Scale: 3/8" = 1'-0"25'-11"2° 3 1/4"9'-2 1/2"5'-10 1/2" 4'-7 5/8" #9 -Base Covers Footings may vary due to site specific soil conditions and frost penetration. The information provided on the pole and sign footings herein are subject to approval by the City and/or Municipality. #3 -Header Channel #7 -Steel Frame #2 -Steel Posts #11 -LED Floodlight #10 -Electric Enclosure 3'-3 3/4" 2'-2 3/4"#3 -Roof Panels #5 -Roof Frame #3 -Header Channel 4'-6"9'-9 5/8"2'-6" Diameter Undisturbed soil (6) # 5 bars #3 ties, 10" c/c (3 in top 5 inches) Concrete foundation Heavy hex nut 1/4" plate, 3" x 3" 3/4" diameter, 36” length A307 anchor bolts #8 -Acrylic Letters #7 -Steel Frame #6 - #11 #7 -3'-5" to center adjustable 37" to 45"9 5/8"3'-8 3/8" monitor space13/16" monitor set back #9 -Base covers 4'-5 1/2" O.A. 1'-4" typ. 4'-0 1/8" Roof 1. 3/4” Anchor bolts 2. Galvanized 3. 4” of AB’s exposed vers vers 54" 81" 123 78 " 4" X 4" PO 7.43 96.93 1 '-0 " 2 '-0 "x 1 '-0 " C O N C R E T E G R A D E B E A M8"8"8"4"4"2' - 0"7"8"1' - 1"8"1' - 9"8"7" 6' - 0" 2' - 5"2"2"2"3' - 1"OF CANOPY ATE F 2)) B-UPS 1' - 0"1' - 0"4"4"LIGHTING 4"(150 : 3' -0")(11")(11")2 '-0 "2 '-0 " 2 '-0 " 2 '-0 "x 1 '-0 " C O N C R E T E G R A D E B E A M W / (3 ) #4 B A R S T O P A N D B O T T O M (3 ) #4 B A R S T O P & B O T T O M NTS D I G I T A L O R D E R B O A R D #2 2 5 4 6 D I G I T A L O R D E R B O A R D Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 April3, 2023_R1 BK 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 24 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** DateFront View Scale: 1/2" = 1'-0"1Front View Scale: 1/2" = 1'-0"2 Photo Overlay Scale: NTS3 Existing Conditions Scale: NTS4 Manufacture and install one (1) set of backlit illuminated sign faces with vinyl graphics for one (1) existing D/F Pole Sign. Sign faces to be cut-out of translucent white .177" polycarbonate. Evolved logo background to be translucent Dark Emerald Green (3M #3630-126) vinyl overlay. “DRIVE THRU” & “TM” lettering to be 3M 220-12 Black vinyl overlay. Paint sign cabinet and pole White (satin finish) (Color TBD). A B C K - D/F Pole Sign (new faces w/ vinyl graphics) Dark Emerald Green (3M #3630-126) White (Color TBD) Note: Field Survey required. ±8'-0"±5'-0"6"Starbucks- East St & Romneya Dr, Tustin, CA 143218_R23'-0 11/16" 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 25 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date1'-6"4'-6"3'-0"Typical Elevation Scale: 1" = 1'-0"2 Sign Post & Hardware Example 1'-6"1'-0" D E L - Parking Sign (PEDESTRIAN CROSSING) Front View Scale: 3" = 1'-0"1 2 1/4" 1'-0" Manufacture and install one (1) parking sign. Panels are .080" routed aluminum with 1/2" radius corners. Face to have applied digitally printed vinyl graphics on white reflective vinyl, See color detail. Font: Pike Bold Sign panel will be fastened to Black U-Channel sign post w/ 2 bolts (5/16" x 2"). Sign post to be Black U-Channel (6'-0" tall, standard 2 1/4" wide). Product #K-153-6MK-BLK. Concrete footing will be 1'-0" x 1'-0" x 1'-6" deep. A B C D E D 3 Color Pallete Corner radius = 1/2"1'-6"NOTE: PANELS ONLY BY TAG, BRACKETS/POSTS/INSTALL BY OTHERS 6 1/2"PEDESTRIANCROSSINGAHEAD PEDESTRIANCROSSINGAHEAD PMS 560C A B B 3 3/8"1 1/2"1 1/2"Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 26 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date1'-6"4'-6"3'-0"Typical Elevation Scale: 1" = 1'-0"2 Sign Post & Hardware Example 1'-6"1'-0" D E M - Parking Sign (VEHICLE CROSSING) Front View Scale: 3" = 1'-0"1 2 1/4" 1'-0" Manufacture and install one (1) parking sign. D Corner radius = 1/2"1 1/2"1 1/2"1'-6"NOTE: PANELS ONLY BY TAG, BRACKETS/POSTS/INSTALL BY OTHERS 6 1/2"CAUTIONVEHICLECROSSING CAUTIONVEHICLECROSSING A B B Panels are .080" routed aluminum with 1/2" radius corners. Face to have applied digitally printed vinyl graphics on white reflective vinyl, See color detail. Font: Pike Bold Sign panel will be fastened to Black U-Channel sign post w/ 2 bolts (5/16" x 2"). Sign post to be Black U-Channel (6'-0" tall, standard 2 1/4" wide). Product #K-153-6MK-BLK. Concrete footing will be 1'-0" x 1'-0" x 1'-6" deep. A B C D E 3 Color Pallete PMS 560C3 3/8"Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 7200 143218 House Brad McKay March 23, 2023 1190 N East St Tustin, CA 92805 TUBE ART G ROUP Seattle Office 11715 SE 5th Street Bellevue, WA 98005 206.223.1122 800.562.2854 Fax 206.223.1123 This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. [ ] Approved [ ] Approved With Changes Noted Revisions Customer Signature Date Landlord Signature Date This drawing is intended to provide a reasonable representation of the nal manufactured article. Fasteners and seams in materials may not be represented exactly as they will be fabricated. Colors on prints may not accurately depict specic colors. 27 of 27 Customer Number Quote Number File Name Salesperson Drawn By Checked By ** Date Starbucks- East St & Romneya Dr, Tustin, CA 143218_R2 Service access screws Service Position- Section View Scale: 3/4" = 1'-0" Vertical Cross Section View Typical Scale: 3/4" = 1'-0"65 Side View Scale: 3/4" = 1'-0"2 Front View Scale: 3/4" = 1'-0"1 Side View Scale: 3/4" = 1'-0"3 Rear View Scale: 3/4" = 1'-0"41'-3"(381mm) 2'-3 13/16" (706mm) 3'-10" (1168mm) 3/8" typ. (10mm) 5 3/16" (132mm) 3"(76mm) 1"(25mm) Open Open AmpsVolts1Sq. Ft.2Sq. Ft.Size 0.851209.903.2246" (1170mm) DT Directional Illuminated Arrow Series - 46in 1170mm 56 21 34 UL label location Disconnect switch-weather proof withsealing bootDisconnect switch-weather proof withsealing boot Electrical junction box CabinetA GraphicsB CS 3"(76mm) x 1 3/4"(44mm) 1.60lbs aluminum channel F 3 1/16" (78mm) 6 1/8"(156mm) 1'-5 3/16"(437mm) 98 Base Detail- Section View Scale: 3" = 1'-0"9 6 1/8"(156mm) 6"(152mm) 3 1/16"(78mm) 1/2"(13mm) 3/4"(19mm) 2"(51mm) x 5"(127mm) x 3/16"(5mm) flat aluminum bar Counter sunk screws 3/4"(19mm) x 3/4"(19mm) x 2"(51mm) x 1/8"(3mm) angle aluminum clips 3"(76mm) x 6"(152mm) x 3/16"(5mm) aluminum base tube. .090"(2mm) aluminum escutcheon plate Counter sunk screws 1 1/2"(38mm) dia. hole for electrical conduit (1 Conduit MAX) Cover opening for electrical Base Detail- Section View Scale: 1 1/2" = 1'-0"74" 6 1/8"(156mm) 4" 1"(25mm) F F 1' 5 3/16" (437mm) Electrical conduit F CS 3"(76mm) x 1 3/4"(44mm) 1.60lbs aluminum channel F 5/8"(16mm) dia. hole(s) for 1/2"(13mm) anchor boltsF Red line indicates the pattern of the escutcheon plate at top showing how plate slots into “C” channel uprights. F 7 2'-0" min.into na turalgrade orengineeredfill 2'-0"(610mm) 1'-6"(457mm) 10 Inside of leg Footings may vary due to site specific soil conditions and frost penetration. The information provided on the pole and sign footings herein are subject to approval by the City and/or Municipality. Enlarged Section View Scale: 3" = 1'-0"10 1/8" aluminum sign face Diffuser film Translucent Dark Emerald Green vinyl 3/8" acrylic- clear flame polished edges Diffuser film 4 total 1. Embed 6” min. 1/2” AB’s 2. Galvanized 3. 2” of AB exposed NOTE: Anchor bolts to be galvanized. Base Detail- Section View Scale: 1 1/2" = 1'-0"8 Escutcheon plate at top N - Custom Directional Sign AA B Cabinet to be fabricated from .090"(2mm) aluminum, painted PMS 560 C. Cabinet to be welded aluminum construction with no visible fasteners on faces. Fasteners retaining the hinged face will be located on the bottom such that they are not visible. All fasteners used in assembly of internal components shall be coated to prevent corrosion. Internal str ucture shall be constructed as per approved shop drawings. Suppor t structure to be welded aluminum “C” channel uprights and aluminum square tube base, painted Black to match RAL 7021M(satin finish). Support structure be constr ucted as per approved shop drawings and shall be integral to the sign cabinet. Base tube to be constructed so that it is retro-fitable to existing sign foundations. All foundations, existing and new must be analyzed for suitability and must meet local city and state code regulations. Sign must meet all regulations in the National Electric Sign Code as well as any local or state codes. As per NEC 600.6 sign is equipt with a service disconnect switch. Sign must be listed as an Electrical Sign per Underwriters Laboratories UL48 and/or CSA and bear the appropriate UL, CUL, or CSA relevant cer tification marks. Primary power by electrical contractor per NEC. D E C Electric SignEnseigne ElectriqueIssue No. E21197 C US F Manufacture and install one (1) double faced backlit illuminated drive thru cabinet sign. Graphic elements are internally illuminated using Sloan Prism Enlighten White 6500k LEDs. LEDs to be mounted on an internal baffle with self contained power supply. All electrical components are removable for service. Sloan power supplyE 3/8" Clear Acrylic net-push thru arrows & “DRIVE THRU” graphics. 3M White translucent vinyl applied to face & 3M Diffuser applied to second surface. Siren logo to have digital print translucent vinyl to match PMS 3425 C applied first surface. 2'-7"8 3/8"2 1/4"3"