Loading...
2244 W. COLCHESTER DR'V‘1PermitTypes●■■ BLD ELE MEC PLM -Xi Permit Number:BLD2021-00114 Issued;01/08/2021 CITY OF ANAHEIM INSPECTION REQUEST LINE: (714)765-4626 Quarter Section:34 BUILDING DIVISION 200 S.ANAHEIM BLVD. (714)765-5153 Site Address:2244 W COLCHESTER DR Legal Description:N TR 2701 LOT 25 Project Description:Reroof:remove and install (2,600)sq ft of shingles onto house and (1,300)torch down onto detached garage. $17,600.00 N/A.. 363.29 Valuation: Conslrucion Types: Total Fees paid for Permit: People Associated with Project: 1439 WESTRIDGE WAY CHINO HILLS CA 91709-2229 528 S HARRIS AVE COMPTON CA 90221 0000 528 S HARRIS COMPOTON CA 90221 Owner MOHAMMAD HASSAN ARAIN TR ENDING ROOFING SILVIA PORTILLO Contractor Permit Applicant QtyQtyTypeQtyTypeMechanicalFixturesElectricalFixturesPlumbingFixturesType The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit issuance.A new permit is required to commence or continue work.fbld_permit_combo FINAL INSPECTIONS DATE INSPECTORCityofAnaheim Building Division All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714)765-4280 Do not occupy this building until the final inspections have been made.Engineering Final (714)765-5126 INSPECTION DATE INSPECTOR Fire Sprinkler (ONLY)(714)765-5041 Do not pour concrete until the following applicable items have been signed:Fire Dept.Final (714)765-5041 Plumbing (Ground/Underfloor Drain Waste)Water Engineering (714)765-4591 Sub List/Bus.Lie.(714)765-5194 (Allow 10 business days)Electrical Ground Electrode/Ufer Setback/Forms/Trenches (Footings)COA/Migation Measures ADonotinstallsubfloororpourfloorslabuntilthefoilwingapplicableitemshavebeen signed Building Final (714 765-5153) Last Inspection-Final Only After Above Completed jU -iWt.£Plumbing (Ground/Underfioor Water) Underfloor Rough Gas PARTIAL INSPECTIONSMechanical(Groundwork) Building InspectionsElectrical(Underground Conduit) Pre-slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been signed:^ 1st Floor Shear Mechanical InspectionsFiresprinkler(Rough)(Fire Dept.) 2nd Floor ShearA RooftSheathing/Diaphragm/Frame) lernf./Bond Beam/Pre-Grout)Masoi Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Plumbing InspectionsRoughCOA/Mitagation Measures Framing (Only after PIbg.,Ele.,Mec.&Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable Items have been signed: Drywall Drywall Penetrations (Ele,Mec &PIbg) Interior Lath Electrical InspectionsExteriorLath Electrical Service Meter-(Meter will be set within 2-3 business days after approval)Excludes New Construction Exterior Plaster (Brown Coat) T-Bar (Struct.,Ele.,or Mec.) Grease Interceptor (Dq not bucklill unless signed oft) Sewer Water Engineering Backflow (Testable Only) Water Service jj!i5fi?TOs<r!;DEPARTMENT ^-W4J●<4. CITY OF ANAHEIM 2016 CALIFORNIA CODES CODE CYCLE 01/01/2017 EFFEC7TVEDATE BUILDING DEPARTMENT 200 S.Anaheim Blvd^Suite 145 Anaheim,CA 92805 714 765-5153 www.anaheim.net/building SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION *Final inspection approval will require this completed form to be on site along with the job card. Project address:2^2-^^r/ Property Owner:Af^/Itc 'i/h /The undersigned does hereby certify that l^m Date:Permit Number: the property owner of the above referenced property,i further certify that smoke alarms and carbon monoxide alarms are present and functional in all the following locations.All boxes must be checked below ^Smoke Alarms and Carbon Monoxide Alarm:On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms. cT Smoke Alarms:In each room used for sleeping purposes. 0^Smoke Alarm and Carbon Monoxide Alarm:In each story,including any habitable basement; (Note:in dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm and a carbon monoxide detector installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.) irages require carbon monoxide detectors.Aii dweliing units with attached < Signature: California Residential Code ^Section R314.6.2,CRC R315.2 states in part that existing dwellings be“retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or in a building that is valued at $1,000 or more.”CRC Section R314.3,CRC R315.2 defines required locations as indicted above. Date: NOTE:This certification is only used when normal access to the interior of the dwelling by the City of Anaheim Inspector is not achieved during the course of project construction,it is normally used for exterior projects such as re-roofing,re-siding,patio covers,solar photovoltaic installations,and similar exterior construction work. FEB 2018200S.Anaheim Blvd.,Suite 145 Anaheim,California 92805 (714)765-5153 Phone (714)765-4607 Fax www.anaheim.net/building B842 SMOKE/CO ALARM REQUIRED LOCATIONS BedroomFamil/RoomBedroomBedroom && T Bath 6>Bedroom Diningc=5\P. Lhring Room Kitchen□ Kitchen LMng Room S8 Bedroom Bedroom —4*H-Figure 1 Figure 2 Ceiling 1 Never^ Here Top of DetectorAcceptableHere AcceptableHere T,, Attic &®2) Wall Bedroom Hall Bedroom Figure 4 Living Room Hall Kitchen Basement Garage Figure 3 REQUIRED SMOKE ALARM LOCATION @5)REQUIRED CARBON MONOXIDE ALARM LOCATION (&