2307 W. BROADWAYHiPermitTypesCITYOFANAHEIMPLMBLDELEMEC
X X X X
BUILDING DIVISION
200 S.ANAHEIM BLVD.
(714)765-5153
Permit Number:BLD2022-028S1
Issued:07/21/2022
www.anaheim.net/building
(714)765-4626
Quarter Section:33
Site Address:2307 W BROADWAYANAHEIM,CA 92804
Legal Description:S TWP 4 RGE 10 SEC 18 SEC 18 T 4 R 10 WLY 225.15 F
APN:12705143
Project Description;New Commercial Constaiction:420 sf.to construct pool restroom/equipment building with attached 317 sf.
California room,outside shower and associated electrical,mechanical and plumbing fixtures.256 sf.to construct freestanding trellis
structure with a fire pit table.REF:TRACT2021-00001 (Tract 19137)
1LivingArea;
Garage Area;
Carport Area;
Balcony /Deck Area;
Cool Roof;
Number of Stories:Valuation:158,000.00
VBConstructionTypes;
Occupancy Groups:
Fire Sprinklered;
Total Fees paid for Permit:
U1
8,151.91
People Associated with Project:
Contractor
Permit Applicant
Owner
8951 RESEARCH DR IRVINE.CA 92618DELCONINC
Monica Ultreras
BROADWAYM 2021 LLC 8951 RESEARCH DR #100
Type Electrical Fixtures Qty Type QtyPlumbingFixtures Mechanical Fixtures Qty
1 1 Ventilation Fan -<=300 cfm on single duct 3DrinkingFountain
Floor Drain
Meter/Disc Sw -Under 600 V.up to 200
amps
Pole Light
Receptacle,switches,lights
Sub Panel/Temp Pwr -Under 600 V,up to
200 amps
3
6
1GasSystem(outlets)
Lavatory
Miscellaneous Fixture
Repair/Drainage Alteration/Vent Piping
Shower
Urinal
30
22
2
1
1
1
3WaterCloset
1WaterDistribution
1WaterHeater
The permit shall expire by limitation and become null and void If the building or work has not passed final inspection 365 days from the
date of permit issuance.A new permit is required to commence or continue work.
DATE INSPECTORFINALINSPECTIONS
City of Anaheim
Building Division
All applicable items below must be signed before utilities are released
Final Gas Test
ZElectricalFinal
Plumbing Final
Mechanical Final
Cross Connection Control (714)765-4280
Do not occupy this building until the final inspections have been made.Engineering Final (714)765-5126
Fire Sprinkler (ONLY)(714)765-5041DATEINSPECTORINSPECTION
Do not pour concrete until the following applicable items have been signed:Fire Dept.Final (714)765-5041
iiji 1^0 Water Engineering (714)765-4591Plumbing(Ground/Underfloor Drain Waste)
Sub List/Bus.Lie.(714)765-5194 (Allow 10 business days)Electrical Ground Electrode/Ufer
COA/Migation MeasuresSetback/Forms/Trenches (Footings)
Do not install subfloor or pour floor slab until the foilwing applicable items have been
signed puilding Final (714 765-5153)
Last Inspection-Final Only After Above Completed J ST'7-2 5 ZiPlumbing(Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONSMechanical(Groundwork)
Building InspectionsElectrical(Underground Conduit)
whin-smk?)Pre-slab (Compaction/Membrane Reinf.)
Floor (Joist/Girders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
been signed:
JSez1stFloorShear
Mechanical InspectionsFiresprinkler(Rough)(Fire Dept.)
2nd Floor Shear
Roof (Sheathing/Diaphragm/Frame)
J5CMasonry(Reinf./Bond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Plumbing InspectionsRoughCOA/Mitagation Measures
Framing (Only after PIbg.,Ele.,Mec.&Fire)
4'1Insulation(Sound/Energy)Z
Do not tape or plaster until the following applicable items have been signed:
Drywall
Drywall Penetrations (Ele,Mec &PIbg)
Interior Lath
1 Electrical InspectionsExteriorLath
r/icjoElectricalServiceMeter-(Meter will be set within 2-3
business days after approval)Excludes New
Construction
Exterior Plaster (Brown Coat)
UjaA
-/I
T-Bar (Struct.,Ele.,or Mec.)
Grease Interceptor
iDn not bnrkfill unless sinned oftl
Sewer
Water Engineering Backflow (Testable Only)
Water Service