777 W KATELLA AVE 414-CPermit Types
BLD
LE
MEC
PLM
X
X
X
X
Permit Number: BLD2023.04347
Issued: 01/09/2024
www. anaheim. nef/bu i Iding
(714)765-4626
Quarter Section: 76
CITY OF ANAHEIM
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714) 765 - 5153
Site Address: 777 W KATELLA AVE 414-C, Anaheim, CA 92802
Legal Description: S TWP 4 RGE 10 SEC 22 T4S R10W SEC 22 FOR OF SW1/4
APN: 08228043
Project Description: DCA - Ghiradelli/BLDG 414 - Tenant Improvement: Mechanical, electrical and plumbing to install new kettle and
hood. Structural for hood support.
Living Area:
Numberof Stories: 1 Valuation: 20,000.00
Garage Area:
Construction Types: VB
Carport Area:
Occupancy Groups:
Balcony / Deck Arco:
Fire Sprinklered:
Cool Rook.
Total Fees paid for Permit: 2,639.50
People Associated with Project:
Permit Applicant Kevin Dahlaky
Owner FIRST AMERICAN TRUST
FSB TR MILDRED MA PO BOX 5046
Contractor PICHETTECO
565 COMMERCE DR 2202109291011214240 FALL RIVER, MA 02720
Engineer - Civil David Alan Balma
132 Tara Terrace Marlton, NJ 08053
Type Electrical Fixtures
Oty Type Plumbing Fixtures Oty Mechanical Fixtures Oty
Conduit and Conductors - per 50 ft.
2 Floor Sink 1 Commercial Hoods (including ducts) 1
Motors - over 1 hp. to 10 h.p.
1 Miscellaneous Fixture 1 Ventilation Fan -> 300 cfm on single duct 1
Receptacle, switches, lights
2
Repair/Drainage AlterationNent Piping 1
Water Distribution
-11
The permit shall expire by limitation and become null and void If the building or work has not passed final inspection 365 days from the
date of permit issuance. A new permit is required to commence or continue work.
P�. "Elm �7<
Cityof Anaheim o� io
Building Division ? i
>
- _
�ovND ED to-
Do not occupy this building until the final inspections have been made.
FINAL INSPECTIONS
DATE
INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
INSPECTION I
DATE I
INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pour concrete until the following applicable items have been si ned
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 765-4591
Electrical Ground Electrode/Ufer
Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days)
Setback/Forms/Trenches (Footings)
JCOAJMigation Measures
Dental install subfloor or pour floor slab until the follwing applicable items have been
sianeol
Building Final (714 765-5153)
Last Inspection -Final Only After Above Completed
6�1
Wt
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Building Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (CompactionlMembrane Reirri
Floor (Joist/Girders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Done' cover or conceal the work below until the following applicable terns have
been signed
list Floor Shear
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
Roof (Sheathing/Diaphragm/Frame)
Masonry (Reinf./Bond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough COA/Mitagation Measures
Plumbing Inspections
Framing (Only after Reg. Ele.. Mee & Firel
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed
Drywall
Drywall Penetrations (Ele, Mec 8, Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter-IMeter will be set within 2-3
business days after approval) Excludes New
Construct on
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele., or Mae.)
Grease Interceptor
Sewer
Water Engineering Backflow (Testable Only)
Water Service