Loading...
777 W KATELLA AVE 414-CPermit Types BLD LE MEC PLM X X X X Permit Number: BLD2023.04347 Issued: 01/09/2024 www. anaheim. nef/bu i Iding (714)765-4626 Quarter Section: 76 CITY OF ANAHEIM BUILDING DIVISION 200 S. ANAHEIM BLVD. (714) 765 - 5153 Site Address: 777 W KATELLA AVE 414-C, Anaheim, CA 92802 Legal Description: S TWP 4 RGE 10 SEC 22 T4S R10W SEC 22 FOR OF SW1/4 APN: 08228043 Project Description: DCA - Ghiradelli/BLDG 414 - Tenant Improvement: Mechanical, electrical and plumbing to install new kettle and hood. Structural for hood support. Living Area: Numberof Stories: 1 Valuation: 20,000.00 Garage Area: Construction Types: VB Carport Area: Occupancy Groups: Balcony / Deck Arco: Fire Sprinklered: Cool Rook. Total Fees paid for Permit: 2,639.50 People Associated with Project: Permit Applicant Kevin Dahlaky Owner FIRST AMERICAN TRUST FSB TR MILDRED MA PO BOX 5046 Contractor PICHETTECO 565 COMMERCE DR 2202109291011214240 FALL RIVER, MA 02720 Engineer - Civil David Alan Balma 132 Tara Terrace Marlton, NJ 08053 Type Electrical Fixtures Oty Type Plumbing Fixtures Oty Mechanical Fixtures Oty Conduit and Conductors - per 50 ft. 2 Floor Sink 1 Commercial Hoods (including ducts) 1 Motors - over 1 hp. to 10 h.p. 1 Miscellaneous Fixture 1 Ventilation Fan -> 300 cfm on single duct 1 Receptacle, switches, lights 2 Repair/Drainage AlterationNent Piping 1 Water Distribution -11 The permit shall expire by limitation and become null and void If the building or work has not passed final inspection 365 days from the date of permit issuance. A new permit is required to commence or continue work. P�. "Elm �7< Cityof Anaheim o� io Building Division ? i > - _ �ovND ED to- Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS DATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714) 765-4280 Engineering Final (714) 765-5126 INSPECTION I DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been si ned Fire Dept. Final (714) 765-5041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765-4591 Electrical Ground Electrode/Ufer Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days) Setback/Forms/Trenches (Footings) JCOAJMigation Measures Dental install subfloor or pour floor slab until the follwing applicable items have been sianeol Building Final (714 765-5153) Last Inspection -Final Only After Above Completed 6�1 Wt Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre -slab (CompactionlMembrane Reirri Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Done' cover or conceal the work below until the following applicable terns have been signed list Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbing Inspections Framing (Only after Reg. Ele.. Mee & Firel Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed Drywall Drywall Penetrations (Ele, Mec 8, Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter-IMeter will be set within 2-3 business days after approval) Excludes New Construct on Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mae.) Grease Interceptor Sewer Water Engineering Backflow (Testable Only) Water Service