Loading...
560 S CITRON STPermiR11 BLD ELE PLM X" Permit Number: BLD2024.04404 Issued: 08/2212024 www.anaheim.net/building (714)765-4626 Quarter Section: 73 CITY OF ANAHEIM BUILDING DIVISION 200 S. ANAHEIM BLVD. (714) 765 •5153 Site Address: 560 S CITRON ST, Anaheim, CA 92805 Legal Description: N TR 217 BLK A LOT 15 - - _ APN: 03616130 Project Description: Retool: Remove and install (21) sq of asphalt shingles over house and detached garage. Living Area: Number of Stones: 1 Valuation: 11,000.00 Garage Area: Construction Types: WA Carport Area: Occupancy Groups: Balcony I Deck Area: Fire Sprinklered: Cool Roof: Total Fees paid for permit: 360.43 People Associated with Project: Permit Applicant Eduardo games Owner KELLY. TREVOR MORGAN 8 JESSICA MARIA 560 S CITRON ST Type Electrical Fixtures Cry Type Plumbing Fixtures Qty Mechanical Fixtures Qty The permit shall expire by limitation and become null and void If the building or work has not passed final Inspection 365 days from the date of permit Issuance. A new permit is required to commence or continue work. P�r,HEIM tq` Cityof Anaheim D� io Building Division i u a �DVNDED 8h^ Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS DATE IIIISPECTOR All applicable items below must be signed before utilities are released - Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714) 765-0280 Engineering Final (714) 765-5126 INSPECTION I DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been signed: Fire Dept. Final (714) 765-6041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765-4591 Electrical Ground Electrode/Ufer Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days) Setback/Forms/Trenches (Footings) COA/Migation Measures Do not install subfloor or pour floor slab until the follwing applicable items have been stonedBuilding Final (714 765-5153) Last Inspection -Final Only After Above Completed Plumbing(Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre -slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been sianed 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbing Inspections Framing (Only after Plbg_ Ele.. Mac & Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter -(Meter will be set within 2-3 business days after approval) Excludes New Construct on Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mec.) Grease Interceptor (Do not backfill unless sinned off) Sewer Water Engineering Backflow, (Testable Only) Water Service CITY OF ANAHEIM BUILDING DEPARTMENT 2016 CALIFORNIA CODES 200 S. Anaheim Blvd., Suite 145 cons 017 Anaheim, CA 92805 Ol/O EPP6GTlV8DAMDATE 714 765-5153 www.anaheimnet/building SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION • Final insnection anoroval will require this completed form to be on site alona with the lob card. Permit Number: 6� 202�(— oq q bq Date: 2 (, S Project address: S 6 6 -S, C �-T o >J S1. ANI;NCr rn 1 CIA 1124" S Property Owner: I re'V-6"" VC-41i" The undersigned does hereby certify that I am the property owner of the above referenced property. I further certify that smoke alarms and carbon monoxide alarms are present and functional in all the following locations. All boxes must be checked below Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate leaping area in the immediate vicinity of bedroomis or in each hallway outside of the rooms. M Smoke Alarms: In each room used for sleeping purposes. a Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement; (Note: in dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upperrAvel.) All dwelling Signature: require carbon monoxide detectors. �N Date: California Residential 6ndd (CRC) Section R314. 2,CRC R315.2 states in part that existing dwellings be "retrofitted with smoke detectors and carbon monoxrde detectors when a building permit is issued for work on or in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as indicted above. NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim Inspector is not achieved during the course of project construction. It is normally used for exterior projects such as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work. 200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax FEB 2018 w .amheim.netlbuilding B842 SMOKE/ CO ALARM REQUIRED LOCATIONS Bedroom Bedroom 6 Bedroom Kitchen TLiving Room 1 Figure 1 Family Room Bedroom VD A Yi Dining Living Room Kitchen V TBWtdfw,m Bedroom Figure 2 4- Acceptable J 4 Here Never Here r Attic Top of Detector /� AA Acceptable Here V Wall Bedroom Halt Bedroom Figure 4 V Living Roan Hail Kitchen Basement I I Garage Figure 3 REQUIRED SMOKE ALARM LOCATION REQUIRED CARBON MONOXIDE ALARM LOCATION