429 N SYRACUSE ST (2)BLD
Permit
Types
X
ELE
X
MEC
X
PLM
I X
Permit Number: BLD2019-03037
Issued: 12/06/2019
INSPECTION REQUEST LINE:
(714) 765 - 4626
Quarter Section: 19
Site Address: 429 N SYRACUSE ST
Legal Description: N TR 3045 LOT 43
CITY OF ANAHEIM
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714) 765 - 5153
Project Description: Residential Addition: 139 sf first floor addition for new entry and enlarged master bathroom. 792 sf new
second floor addition for two new bedrooms, bathroom, and sifting area. 115 sf covered porch at entry. 257 sf remodel to
convert existing bedroom into stairway and bathroom. Remove existing roof material and install 1714 sf of new Boral Claylite
(5.9 Ibs) tile roof. Plumbing to change out water heater to tankless and electrical to change out subpanel.
Living Area: 931 Valuation: $80,000.00
Construcion Types: VB, ,
Fire Spdnklered7 No
Cool Roof No
Total Fees paid for Permit: 7,328.71
People Associated with Project:
Owner ANA ROSA LICEA 429 N SYRACUSE ST ANAHEIM CA 92801-4830
Engineer KAMAL MCHANTAF 23315 SARATOGA SPRINGS PLACE MURRIETA CA 92562
Permit Applicant ANTONIO LICEA 429 N SYRACUSE ANAHEIM
Type Electrical Fixtures
City
Type Plumbing Fixtures
Receptacle, switches, lights
59
Bath Tub
New or total rewire - garage/carport
440
Shower
New or total rewire - 1 or 2 family
931
Lavatory
Sub Panel(Temp Pwr - < 600 V, 0 < amps
1
Water Closet
<= 200
Kitchen Sink
Garbage Disposal
Repair/Drainage AlterationNent Piping
Dishwasher
Water Heater
Water Distribution
Gas System (1-5 outlets)
City Type Mechanical Fixtures
1 Heating Appliances, including vent
3 Ventilation Fan -> 300 cfm on single duct
4
3
1
1
1
1
1
1
1
Qb
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of
permit issuance. A new permit is required to commence or continue work. 'cid_permit _combo
Pal ttEIM C
Cityof Anaheim D� iO
Building Division _� i
U >
• �I LADED ts�^
Do not occupy this building until the final inspections have been made.
FINAL INSPECTIONS
DATE
INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
Plumbing Final ` ' '
Mechanical Final S
Cross Connection Control (714) 765 C
MF
Engineering Final (714) 765-5126
INSPECTION
DATE I
INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5 1
Do not pour concrete until the following applicable items have been signed.
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 765.4591
Electrical Ground Electrode/Ufer
Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days)
Setback/Forms/Trenches (Footings) f get
COA/Migation Measures
Do not install subfloor or pour floor slab until the ollwing app is le items have been
Building Final (714 765-5153)
Last Inspection -Final Only After Above Completed
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Building Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
Floor (JoisVGirders)
2
Underfloor Insulation (Raised Foundation Only)
n
l.�
_
p C
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
1st Floor Shear
i j e
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear°�
20
Roof (Sheathing/Diaphragm/Frame)
c,
Masonry (Reinf.iBond Beam/Pre-Grout)
Rough Plumbing (Top Out)
2
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
IZ ^G
Rough COA/Mitagation Measures
Plumbing Inspections
��1�
Framing (Only after Plbg.. Ele .. Mec. & Fire)
Insulation (Sound/Energy)"
($M
Do not tape or plaster until the following applicable items have been signed:
Drywall
20 Z
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter -(Meter will be set within 2-3
business days after approval) Excludes New
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele., or Mec.)
Grease Interceptor
in, not hnckfill unless sinned nff)
Sewer
Water Engineering Backflow (Testable Only)