202 N ROYAL PL (2)Permit Types BLR - PtE - EC PLM Permit Number: BL02024-01223 Issued: 03/11/2024 www.anaheim.netlbu i Iding (714)765-4626 Quarter Section: 122 Site Address: 202 N ROYAL PL, ANAHEIM, CA 92806 Legal Description: N TR 3390 BLK LOT 97 CITY OF ANAHEIM BUILDING DIVISION 200 S. ANAHEIM BLVD. (714) 766 .5153 APN: 26828315 AM Project Description: Reroof to remove and install (17) squares of cap sheet over flat roof and (11) squares of composition shingles over pitched roof of house and attached garage Living Area: Number of Stories: 1 Valuation: 9.800.00 Garage Area Construction Types: N/A Carport Area: Occupancy Groups: Balcony / Deck Area: Fire Sprinklered: Cool Roof: Total Foos paid for Pennit: 350.27 People Associated with Project: Contractor AMERICAN SUPREME ROOFING 501 S KING ST SANTA ANA, CA 92704 Permit Applicant Kathleen Lopez Owner PETERSON, DOLORES W TR 202 N ROYAL PL Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures Qty The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit Issuance. A new permit is required to commence or continue work. LaPNElm Cf City of Anaheim DFP t'O Building Division F 2 O > OVNDED Lay^ Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS ATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714) 765-4280 Engineering Final (714) 765-5126 INSPECTION I DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been signed. Fire Dept. Final (714) 765-5041 Plumbing (GroundlUnderfloor Drain Waste) Water Engineering (714) 765-4591 Electrical Ground Electrode/Ufer El Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days) Setback/FormsRrenches (Footings) COA/Migation Measures Do not install subfloor or pour floor slab until the follwing applicable items have been Building Final (714 765-5153) Last Inspection -Final Only After Above Completed " Y Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre -slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been soned 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd FI Roo (Sheathing) phragm/Frame) 3-Z2.-24 Mason elnf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbing Inspections Framing (Only after Plbg., Ele_ Mec. 8 Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed. Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter -(Meter will be set within 2-3 business days after approval) Excludes New Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mec.) Grease Interceptor Sewer Water Engineering Backflow, (Testable Only) Water Service CITY OF ANAHEIM BUILDING DEPARTMENT 2016 CALIFORNIA CODES 200 S. Anaheim Blvd., Suite 145 CODE CYCLE Anaheim, CA 92005 01/01/2017 714 765-5153 EFFECTL DATE w .anaheim.net/building SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION Final inspection approval will require this completed form to be on site along with the job card. Permit Number: j5U/�DL /!�� b ZZ -3 Date: zZ Z Project address:' /v g—ON mot' Property Owner: 2 f/O/Dlfij The undersig ed does hereby certify That I am the property owner of the above referenced property. I further certify that smoke alarms and carbon monoxide alarms are present and functional in all the following locations. All boxes must be chedked below f Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms. P Smoke Alarms: In each room used for sleeping purposes. Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement; (Note: in dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.) All dwelling units with attached garages require carbon monoxide detectors. Signature: 'lam/ Date: 3/ California Residential Code (CRC) Section R314.6.2,CRC R315.2 states in part that existing dwellings be "retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as indicted above. NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim Inspector is not achieved during the course of project construction. It is normally used for exterior projects such as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work. 200 S. Anaheim Blvd_guite 145 Anah6m, California 92605 (714)765-5153 Phone (714)7655-4607 Fax- w .anaheim.neUbuilding SMOKE/ CO ALARM REQUIRED LOCATIONS Figure t Bedroom Living Room Attic t� II@7 L Hall Family Room Bedroom C k Dining Living Room Kitchen 8D A �D Bedroom Bedroom Figure 2 Bedroom Kitchen [t Acceptable, a Here Never Here err Top of Detector Acceptable Here Figure 4 6co 11 Basement Figure 3 REQUIRED SMOKE ALARM LOCATION CD REQUIRED CARBON MONOXIDE ALARM LOCATION Wall