829 S CLAUDINA ST BPermit Types
BLD
ELE
MEC
PLM
X
X
X
X
Permit Number: BLD2023-05329
Issued: 12/07/2023
www.anaheim.net/building
(714)765-0626
Quarter Section: 84
Site Address: 829 S CLAUDINA ST B, ANAHEIM, CA 92805
Legal Description: N TR 14 BLK LOT 30
APN: 03708117
CITY OF ANAHEIM
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714) 765 - 5153
Project Description: (ADU) Residential Addition: 365 sq ft to convert existing detached garage into accessory dwelling unit. (1 BD/1 BA)
Living Area:
Garage Area:
Carport Area:
Balcony I Deck Area:
cool Roof:
People Associated with Project
365 Number of Stories:
1 Valuation:
Construction Types:
Occupancy Groups:
Fire Sprinklered:
Total Fees paid for Permit;
70,000.00
Ve
No
2,198.99
Contractor
GCSUNRISE LLC
1439 W CHAPMAN AVE #297202010271256010984 ORANGE, CA 92868
Permit Applicant
Veronica Jaimes
Owner
VARGAS, JOSEPHINE S TR
1161 CAREN RD
Engineer- Mechanical
RAYMOND ZHONG
2416 W VALLEY BLVD201710171207578860 ANAHEIM, CA 91803
Engineer - Civil
Maciej W Czajkowski
300 E. 23rd at Costa Mesa, CA 92627
Type Electrical Fixtures City Type Plumbing Fixtures
Receptacle, switches, lights 27 Dishwasher
Sub Panel/Temp Pwr- Under 600 V, up to Garbage Disposal
200 amps
Kitchen Sink
Lavatory
Repair/Drainage AlterationiVent Piping
Shower
Washing Machine Rough
Water Closet
Water Healer
y Mechanical Fixtures oty
1 Mini Split (Exterior condenser) 1
1 Mini Split (room unit) 1
1 Ventilation Fan - <= 300 cfm on single duct 3
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the
date of permit issuance. A new permit is required to commence or continue work.
P�PHEIM oq`
Cityof Anaheim O� !nO
Building Division f z
10
VA'DEp raft^
Do not occupy this buildino until the final inspections have been made.
FINAL INSPECTIONS
DATE
INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
3 1 dN
Electrical Final
b ? 4
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
INSPECTION I
DATE I
INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pour concrete until the following applicable items have been signed:
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
2[_�-24
Water Engineering (714) 765-4591
Electrical Ground Electrode/Ufer
Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days)
Setback/Forms/Trenches (Footings)
COA/Migation Measures
Do not install subfloor or pour floor slab until the follwing applicable items have Deen
sinnedBuilding
Final (714766-5153)
Last Inspection -Final Only After Above Completed
// /��„/Zy
T /
Lam/
Plumbing (Ground/Underfloor Water) 7 Z._Z
Underfloor Rough Gas
PARTIAL INSPECTIONS
Building Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
Floor (Joist/Girders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
1st Floor Shear
/ Z.0
X—
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
Roof (Sheathing/Diaphragm/Frame)
Masonry (Reinf./Bond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
'
Rough COA/Mitagation Measures
Plumbing Inspections
Framing Only after Plhg Ele Mec & Fire)/
Insulation (Sound/Energy)
I
Go not tape or plaster until the following applicable teml have been signed
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter -(Meter will be set within 2-3
ousrness days after approval) Excludes New
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele, or Mec.)
Grease Interceptor
Sewer
Water Engineering Backflow, (Testable Only)
Water Service