912 N CLAUDINA STPermit Types
hLD 1 ELE MEC PLM
X
Permit Number: BLD2024-05004
Issued: 09/20/2024
vivivir.anaheim.net/building
(714)765-4626
Quarter Section: 71
CITY OF ANAHEIM
Site Address: 912 N CLAUDINA ST H-LITE, ANAHEIM, CA 92805
Legal Description: N TR 422 BLK 5 LOT 3
APN: 03506221
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714) 765 - 5153
Project Description: Reroof: Remove and install (270) squares of composition shingles over building (Units A-D)
Living Area: Number of Stones: 0 Valuation:
Garage Area: Construction Types:
Carport Area: Occupancy Groups:
Balcony / Deck Area:
Fire 5pnnklered:
Cool Roof: Total Fees paid for Perme:
24.000.00
N/A
914.12
People Associated with Project:
Contractor MJ ROOFING INC
13D69 ALEXANDER STREET SYLMAR, CA
Permit Applicant MARCO AZULOAGA RAMIREZ, CEO
13069 ALEXANDER ST SYLMAR, CA 91342
Owner LE. HUNG VAN TR
12472 GLEN ST
Type Electrical Fixtures Oty Type Plumbing Fixtures Oty Mechanical Fixtures Oty
The permit shall expire by limitation and become null and void If the building or work has not passed final Inspection 365 days from the
date of permit Issuance. A new permit is required to commence or continue work.
HPHEIM (.9
Cityof Anaheim DFP `��O
Building Division F i
u >
• �0GNDEo Leh^
Do not occupy this building until the final inspections have been made.
FINAL INSPECTIONS
DATE
INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
INSPECTION I
DATE I
INSPECTOR
Fire Sprinkler (ONLY) (714) 765-6041
Do not pour concrete until the following applicable items have been signed:
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 7654591
Electrical Ground ElectrodelUfer
Sub List/Bus. Lic. (714) 765.5194 (Allow 10 business days)
SetbacklFormsn'renches (Footings)
COAIMigation Measures
Do not install subfloor or pour floor slab until the follwing applicable items have been
cried
Building Final (714765-5153)s
Last Inspection -Final Only Attar Above Completed
fhf�
Plumbing(GroundlUnderfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Building Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
Floor (JoisUGirders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
been sianed
list Floor Shear
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
Roof (Sheathing/Diaphragm/Frame)
OQ t
Masonry (Reinf.lBond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough COAIMitagation Measures
Plumbing Inspections
Framing (Only after Plbg.. Ele., Mec. & Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed.
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter -(Meter will be set within 2-3
business days after approval) Excludes New
Construction
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele., or Mec.)
Grease Interceptor
(Do backf 11 unless varied off)
not
Sewer
Water Engineering Backflow (Testable Only)
Water Service
BUILDING DIVISION
CITY OF ANAHEIM
BUILDING DEPARTMENT 2016 CALIFORNIA CODES
200 S. Anaheim Blvd., Suite 145 CDDt I I, IF
Anaheim, CA 92805 01/01/2017
714 765-5153 H =IVF. DATE
v .anaheim.net/building
SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION
Final inspection approval will require this completed form to be on site alona with the iob card.
Permit Number: �(t �/ f V®J Date: s 202-V
Projectaddress: 6'1z 1\) . eL4Jr'b" �1 __ )v►�Mc!M -
Property Owner: t j:l )1Nfi. inC
The undersigned does hereby certify that I am the property owner of
above referenced
property. I further certify that smoke alarms and carbon monoxide alarms are present and
functional in all the following locations. All boxes must be checked below
IN Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate
sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms.
M Smoke Alarms: In each room used for sleeping purposes.
161 Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement;
(Note: in dwellings or dwelling units with split levels and without an intervening door between
the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level
shall suffice for the adjacent lower level provided that the lower level is less than one full story
below the upper level.)
All dwelling units 1pitp attached
Signature:
require carbon monoxide detectors.
California Residential Code (CRC) Skction R314.6.2,CRC R315.2 states in part that existing dwellings be
'retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or
in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as
indicted above.
NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim
Inspector is not achieved during the course of project construction. It is normally used for exterior projects such
as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work.
200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax FES 2018
w .anaheim.netlbuilding B842
g2go_�—
SMOKE/ CO ALARM REQUIRED LOCATIONS
Bedroom Bedroom
Balh Bedroom
Kitchen
Living Room
Figure t
Family Room
Bedroom
Dining
Living
Roan
Kitchen
Bedroom
Bedroom
Figure 2
Figure 3
REQUIRED SMOKE ALARM LOCATION
ly,;�] REQUIRED CARBON MONOXIDE ALARM LOCATION
4-
Acceptable � Never
Here Here
Top of Detector
Acceptable Here