530 W CHESTNUT ST (2)Permit Types
BLD ELE MEC PLM
X
Permit Number: BLD2024.04985
Issued: 09/19/2024
www.anaheim.nettbu ilding
(714)765-4626
Quarter Section: 73
Site Address: 530 W CHESTNUT ST, Anaheim, CA 92805
Legal Description: A TR ENTERPRISE TR BLK 2 LOT 18
APN: 25111133
CITY OF ANAHEIM
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714) 765 - 5153
Project Description: Reroof: To remove and install (20) of composition shingles over house only
Living Area: Number of Stones: 1 Valuation:
Garage Area: ConsWction Types:
Carport Area: Occupancy Groups:
Balcony / Deck Area:
Cool Roof
Fire Sprinklered:
Total Fees paid for Penult:
People Associated with Project:
Contractor AMERICAN SUPREME ROOFING 501 S KING ST SANTA ANA. CA 92704
Permit Applicant Daniel Vazquez
Owner NG, SELAINE L TR S L NG 9142 ROSANNA AVE
8,500.00
NIA
357.11
Type Electrical Fixtures City Type Plumbing Fixtures Oty Mechanical Fixtures Oty
The permit shall expire by limitation and become null and Void if the building or work has not passed final inspection 365 days from the
date of permit issuance. A new permit is required to commence or continue work.
Nrt{EIM Cq
Cityof Anaheim O4 P `'�O
Building Division i
� '
�OVN
Do not occupy this building until the final inspections have been made.
FINAL INSPECTIONS
DATE
INSPECTOR
All applicable items below must be signed before utilities am released
Final Gas Test
Electrical Final
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
INSPECTION
DATE
INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pour concrete until the following applicable items have been signed.
Fire Dept. Final (714) 765.5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 766.4591
Electrical Ground ElectrodelUfer
Sub LisVBus. Lie. (714) 765-5194 (Allow 10 business days)
Setback/Forms/Trenches (Footings)
COAIMigation Measures
Do not install subfloor or pour floor slab until the foilwing applicable items have been
i
Building Final (714 765-5153)
Last Inspection -Final Only After Above Completed
\ti
Plumbing(GroundlUnderfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Building Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
Floor (JoistlGirders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
1st Floor Shear
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
Roof (SheathinglDiaphmgmlFrame)
Masonry (Reinf.lBond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough COAIMitagation Measures
Plumbing Inspections
Framing (Only after Plbg., Ele., Mee. & Fire)
Insulation (SoundlEnergy)
Do not tape or plaster until the following applicable items have been signed.
Drywall
Drywall Penetrations (Ele, Mee & Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter -(Meter will be set within 2-3
business days after approval) Excludes New
Construction
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele., or Mee.)
Grease Interceptor
Sewer
Water Engineering Backflow (Testable Only)
Water Service
BUILDING DIVISION
CITY OF ANAHEIM
BUILDING DEPARTMENT 2016 CALIFORNIA CODES
200 S. Anaheim Blvd., Suite 145 ,.ODE cress
Anaheim, CA 92805 01/01/2017
714 765-5153 s//EC=DATE
w .anaheim.net/building
SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION
" Final inspection approval will require this completed form to be on site alongwith the job card
Permit Number:"/ Z42— I Date: Ij D )02- I2024')
Project address: )0 3 W Chec 4W u ' S}, An i h e7lm CH g 28o 5
Property Owner: Selcline NA
The undersigned does hereby' certify that I am the property owner of the
property. I further certify that smoke alarms and carbon monoxide alarms
functional in all the following locations. All boxes must be checked below
above referenced
are present and
l Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate
sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms.
t Smoke Alarms: In each room used for sleeping purposes.
Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement;
(Note: in dwellings or dwelling units with split levels and without an intervening door between
the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level
shall suffice for the adjacent lower level provided that the lower level is less than one full story
below the upper level.)
All dwelling units with attached garages require carbon monoxide detectors.
Signature:
U)2-
California Residential Code (CRC) Section R314.6.2,CRC R315.2 states in part that existing dwellings be
"retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or
in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as
indicted above.
NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim
Inspector is not achieved during the course of project construction. It is normally used for exterior projects such
as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work.
200 S. Anaheim Blvd., Suite 145 Anaheim, Califomia 92805 (714)765-5153 Phone (714)765-4607 Fax FEB 2018
w .anaheim.net/building B842
SMOKE/ CO ALARM REQUIRED LOCATIONS
Figure t
Bedroom
Family Room
WI 6
Dining
Living Room
Kitchen
Bedroom
Bedroom
Figure 2
/ Attic \
6
Bedroom Hall Bedroom
Living Room
6
Basement
Hull I Kitchen
Figure 3
REQUIRED SMOKE ALARM LOCATION
REQUIRED CARBON MONOXIDE ALARM LOCATION
Ceilin I4 I
Here
Acceptable 4.
Here Never
Top of Detector
Acceptable Mere
Garage
Figure 4
wall