777 W KATELLA AVE (14)Moll
--------------
Permit Types
BLD 1 ELE MEC PLM
X
Permit Number: BLD2024-03227
Issued: 06/27/2024
www.anaheim. nettbuild i ng
(714)765-4626
Quarter Section: 76
CITY OF ANAHEIM
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714) 765 - 5153
Site Address: 777 W KATELLA AVE, Anaheim, CA 92802
Legal Description: S TWP 4 RGE 10 SEC 22 T4 R10 SEC 22 FOR OF W 1/2
APN: 08219027
Project Description: DCA - Golden State - Halloween Party - Miscellaneous: Install (5) truss
arches, (1) truss arch anchored to concrete
ballast blocks. (10131/2024 thru 11/07/2024)
Living Area: Number of Stones:
0 Valuation: 25,000.00
Garage Area:
Construction Types: N/A
Carport Area:
Occupancy Groups:
Balcony I Deck Area:
Fire Spdnklered:
Cool Root
Total Fees paid for Permit: 858.00
People Associated with Project:
Owner WALT DISNEY PARKS AND RESORTS US INC PO BOX 313
Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures Qty
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the
date of permit issuance. A new permit is required to commence or continue work.
City of Anaheim
Building Division
Do not occupy this building until the final inspections have been made.
INSPECTION I DATE I INSPECTOR
Do not pour concrete until the following applicable items have been signed.
lumbing (Ground/Underfloor Drain Waste)
lectrical Ground Electrode/Ufer
or pour floor slab until the follwing
Underfloor Rough Gas
Mechanical (Groundwork)
Electrical (Underground Conduit)
lerfloor Insulation (Raised Foundation
)r Nailing (Raised Foundation Only)
Floor (Floor Nailing)
o not cover or conceal the work below until
been signer
Floor Shear
sprinkler (Rough) (Fire Dept.)
2nd Floor Shear
Roof (Sheathing/Diapi
Masonry (Reinf./Bond
Duct (Mach
Mechanical
Electrical
OAIMitagation Measures
(Only after Plbg., Ele.. Mac & Fire)
have
Do not tape or plaster until the following applicable items have been signed.
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Service Meter -(Meter will be set within 273
business days after approval) Excludes New
Construct on
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele., or Meli
FINAL INSPECTIONS I DATE I INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765.4280
Engineering Final (714) 7655126
Fire Sprinkler (ONLY) (714) 765.5041
Fire Dept. Final (714) 7655041
Water Engineering (714) 765-4591
Sub List/Bus. Lic. (714) 766.5194 (Allow 10 business days)
eOAlMigation Measures
Building Final (714 765-5153)
Last Inspection -Final Only After Above Completed
PARTIAL INSPECTIONS
Building Inspections
Mechanical Inspections
Plumbing Inspections
Electrical Inspections
Backflow
Service
IN
W H E E L E R & G R A Y, I N C
CONSULTING ENGINEERS
Field Observation Report
BLD2024-03227
DATE: August 22, 2024
SUBJECT: Halloween Party Temporary Structures 2023
Disney's California Adventure - Disneyland Resort
777 W. Katella Ave. Anaheim, CA 92802
FROM: Ken Agee
REMARKS:
Phone #: (626) 893-4672
A structural observation was on performed on August 22, 2024 at the project site in order to
review the installation of the temporary structures at the Disneyland Resort installed for the
Halloween Party 2024 event. Here are the comments in regards to the construction:
1. The installation is constructed and installed in accordance with the approved design
drawings.
Ken Agee, S.E. 3340
300 SOUTH HARBOR BLVD., SUITE 1010 • ANAHEIM • CALIFORNIA • 92805 • (714) 937-9100