401 S FANN ST (2)• Permit Types
SLID
ELE
MEC
PLM
X
X
Permit Number: BLD2024-03405
Issued: 08/14/2024
www.anaheim.net/building
(714)765-4626
Quarter Section: 47
CITY OF ANAHEIM
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714)765. 5153
Site Address: 401 S FANN ST, ANAHEIM, CA 92804
Legal Description: N TR 2402 BLK LOT 5
APN: 12809305
Project Description: Photovoltaic System with Inverters: Installation of residential roof mounted system with (16) modules and (16)
micro -inverters
Living Area: Number of Stories:
i valuation:
10,880.00
Garage Area:
Consbuceon Types:
NIA
Carpon Area:
Occupancy Groups:
Balcony I Deck Area:
Fire Spdnklered:
No
Cool Roof:
Total Fees paid for Permit:
916.41
People Associated with Project:
Contractor EXO ENERGY INC
34253 MAZARINE DR TEMECULA, CA
Permit Applicant Michael Espinoza
Owner KIDWELL, BENNIE SUE
401 S FANN ST
Type Electrical Fixtures Qty Type
Plumbing Fixtures Oty Mechanical Fixtures
Qty,
Microinverter 16
The permit shall expire by limitation and become null and void if the building or work has not passed final Inspection 365 days from the
date of permit issuance. A new permit is required to commence or continue work.
<J PHEIM C
Cityof An a h e i m Ok P� / o
Building Division 2
>
• FOVNDED.�b
Do not occupy this building until the final inspections have been made.
FINAL INSPECTIONS
DATE
INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
23 L
siY,V�
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
INSPECTION I
DATE
INSPECTOR
Fire Sprinkler (ONLY) (714) 7655041
Do not pour concrete until the following applicable items have been signed:
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 765.4591
Electrical Ground ElectrodelUfer
Sub LisVBus. Lic. (714) 7654194 (Allow 10 business days)
Setback/Forms/Trenches (Footings)
COAIMigation Measures
Do not install subfloor or pour floor slab until the follwing applicable items have been
sinned -
Building Final (714765-5153)
Last Inspection -Final Only After Above Completed
rL �2
S
Plumbing Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Building Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
Floor (JoistiGirders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
list Floor Shear
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
Roof (SheathinglDiaphregmlFrame)
Masonry (Reinf.lBond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough COAIMitagation Measures
Plumbing Inspections
Framing (Only after Plbg., Ele., Mee. & Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed:
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter -(Meter will be set within 2-3
business days after approval) Excludes New
Construction
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele., or Mee.)
Grease Interceptor
Sewer
Water Engineering Backflow (Testable Only)
Water Service
CITY OF ANABEIM
BUILDING DEPARTMENT
200 S. Anaheim Blvd., Suite 145
Anaheim, CA 92605
714 765-5153
w .anaheim.net/building
SMOKE DETECTORS AND CARBON
` Final Inspection approval will require this con
Permit Number: RIP z C 1 ` 0 JKK [DC
Project address: l (1 5, r 4nrl St -
2013 CALIFORNIA CODES
CODE CYCLE
01/01/2014
EFFECTDATE
MONOXIDE SELF CERTIFICATION
Dieted form to be on site alona with the iol
Date: 9/2 )
Property Owner: 6t4""I't SUY K I d ot. I
The undersigned does hereby certify that I am the property owner of the above referenced
property. I further certify that smoke alarms and carbon monoxide alarms are present and
functional in all the following locations. All boxes must be checked below
Ef Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate
sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms.
Smoke Alarms: In each room used for sleeping purposes.
P Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement;
(Note: in dwellings or dwelling units with split levels and without an intervening door between
the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level
shall suffice for the adjacent lower level provided that the lower level is less than one full story
below the upper level.)
All dwelling units with attached garages require carbon monoxide detectors. }
Signature: !d �Z //G�( Date: 2 Z 1
California Residential Code (CRC) Section R314.6.2,CRC R315.2 States in part that existing dwellings be
"retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or
in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as
indicted above.
NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim
Inspector is not achieved during the course of project construction. It is normally used for exterior projects such
as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work.
200 S. Anaheim Blvd., Suite 145
Anaheim, California
92805 (714)765-5153 Phone
(714)765-4607 Fax
SEPT 2015
w .anaheim.nel/building
B842
SMOKE/ CO ALARM REQUIRED LOCATIONS
Figure 1
Bedroom
Living Room
Basement
Attic
N
Family Room Bedroom
Dining
Living Room
Kitchen
aro � m�ro
s, r
...B edroom
Figure 2
Bedroom
Kitchen
Figure 3
REQUIRED SMOKE ALARM LOCATION
REQUIRED CARBON MONOXIDE ALARM LOCATION
CeilingI
Acceptable a
Here Never
Here -T12-
Top of Detector
Acceptable Here
Garage
Figure 4
Wall