156 N IMPERIAL HWY (2)Permit Types BLD ELE MEC PLM X X Permit Number: BLD2021-03362 Issued: 02/08/2024 www.anaheim.net/building (714)7654626 Quarter Section: 185 CITY OF ANAHEIM BUILDING DIVISION 200 S. ANAHEIM BLVD. (714) 765. 5153 Site Address: 156 N IMPERIAL HWY, ANAHEIM, CA 92807 Legal Description: APN: 35819112 Project Description: EV Charger: Install (16) new EV chargers, (1) 1662 kva transformer, (1) 2000 amp switchgear and (4) 600 amp supercharger cabinets. Partial restripe, new concrete curb and create accessible path of travel. Living Area: Number of Stories: 0 Valuation: 360,000.00 Garage Area: Construction Types: Not Applicable Carport Area: Occupancy Groups: Balcony / Deck Area: Fire Sprinklered: Cool Roof: Total Fees paid for Permit: 5,091.00 People Associated with Project: Owner CANYON PLAZA LLC 503 32ND ST SUITE 200 NEWPORT BEACH, CA 92663 Contractor ALLEGIANCE ELECTRIC INC 39952 QUIGLEY RD MURRIETA, CA Engineer- Civil Tanya Brix 7866 Via Coscoja Carlsbad, CA 92009 Type Electrical Fixtures City Type Plumbing Fixtures Cry Mechanical Fixtures City EV Charger 16 Generators/Transformers - over 10 hp, 1 over 75 kva Meter/Disc Sw -> 600 V, 1000 to 2500 1 amps Sub Panel/Temp Pwr - < 600 V, 500 < 4 amps <= 1000 The permit shall expire by limitation and become null and void if the building or work has not passed final Inspection 365 days from the date of permit issuance. A new permit is required to commence or continue work. �PHgI,N Cq Cityof Anaheim O� P <�O Building DIVISION F y u ' �OVNDED t8ft^ Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS DATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test Electrical Final �0 1grh' Plumbing Final Mechanical Final Cross Connection Control (714) 765-4280 Engineering Final (714) 765-5126 INSPECTION I DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been signed-. Fire Dept. Final (714) 765-5041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765-4591 Electrical Ground Electrode/Ufer Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days) Setback/Forms/Trenches (Footings) COA/Migation Measures Do not install subBoor of pour floor slab until the follwing applicable items have been sioned Building Final (714 765.5153) Last Inspection -Final Only After Above Completed r OI �` W Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Buildinq Inspections Mechanical (Groundwork) Electrical (Underground Conduit) N 17-1t Pre -slab (Compaction/Membrane Reinf.) r( Floor (JoisVGirders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following api: - cems Nava tat Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbing Inspections Framing (Only after Plbg Ele Mec & Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter -(Meter will be set within 2-3 business days after approval) Excludes New [ 6/ Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mec.) Grease Interceptor (Do not backfiff unless turmpri off I Sewer Water Engineering Backflow (Testable Only) Water Service