Loading...
954 S CANYON HEIGHTS DR-wmit Types 1-LLD EL MEC PLM X X X X 9t7�° Permit Number: BLD2018-02322 Issued: 02/15/2019 INSPECTION REQUEST LINE: (714) 765 - 4626 Quarter Section: 232 Site Address: 954 S CANYON HEIGHTS DR Legal Description: CITY OF ANAHEIM BUILDING DIVISION 200 S. ANAHEIM BLVD. (714) 765 - 5153 9 Project Description: (CY2) New Residential Construction: 3,249 sq.ft. to construct new two-story single family residence with 45 sq.ft. covered entry porch and 424 sq.ft. attached garage. 410 sq.ft. covered patio and 410 sq.ft. balcony. Living Area: 3,252 Valuation: $500,000.00 Garage Area 424 Construcion Types: VB, , Patio Area: 410 Occupancy Groups: R3, U. , , Balcony / Deck Area: 410 Fire Spdnklered? Yes Cool Roof No Total Fees paid for Permit: 5,039.24 People Associated with Project Owner NORMAN HOMEN 954 S CANYON HEIGHTS DR ANAHEIM CA 92808-1682 Engineer KEITH WISMER 2601 E CHAPMAN AVE 116 FULLERTON CA 92831 0000 Contractor IKON BUILDERS INC 32158 CAMINO CAPISTRANO SAN JUAN CAPISTRANO CA 93675 Permit Applicant ANTHONY LOPEZ Engineer JAMES TUCHSCHER 1225 N HOLLYDALE DR FULLERTON CA 92831 Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Type Mechanical Fixtures Oty Receptacle, switches, lights 152 Bath Tub 3 Heating Appliances, including vent 1 Meter/Disc Sw - under 600 V, up to 200 1 Shower 2 Heating/Cooling Coil 1 amps Lavatory 6 Compressor/Boiler- up to 15 hp 1 Water Closet 5 Residential Registers 15 Kitchen Sink 1 Heating/Cooling Coil 1 Garbage Disposal 1 Ventilation Fan - <= 300 cfm on single duct 8 Dishwasher 1 Washing Machine Rough 1 Water Heater 1 Gas System (1-5 outlets) 3 Water Main per 100 ft. 1 Sewer per 100 ft. 1 The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit issuance. A new permit Is required to commence or continue work. flod_permn_combo aP1iEIM �� City of Anaheim DF P `'�O Building Division z q "VDED v8y^ Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS DATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714) :" UUI LE Engineering Final (714) 766.5126 INSPECTION I DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 7 T • Do not pour concrete until the following applicable items have been signed: Fire Dept. Final (714) 7655041 Plumbing (Ground/Underfloor Drain Waste) do Water Engineering (714) 765-4591 Electrical Ground Electrode/Ufer Sub List/Bus. Lic. (714) 7655194 (Allow 10 business days) Setback/Forms/Trenches (Footings) 3,) r'r ,off.. COAIMIgation Measures Do not install subfloor or pour floor slab until the follwing applicable items have been sioned Building Final (714 7655153) Last Inspection -Final Only After Above Completed Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections ., r_ a ; < \ - 2 J) 7„ V,27/1 Mechanical (Groundwork) Electrical (Underground Conduit) 7- 'trT,7 p Pre -slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) Cor �aa� i �ro-ctn lz Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) 7/i'> / .- PZ 1 , Do not cover or cone,: -:: work below until the following applicable items have been soned 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical OWL ZAC Rough Electrical 1 A'r— Rough COAIMitagation Measures Plumbing Inspections (2-) j I I)A I.? Framing (Only after Plbg., Ele., Mec. & Fire) 7 f to #-i Insulation (Sound/Energy) //; Ham. Do not tape or plaster until the following applicable items have been signed Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath H j Exterior Lath k,10,C Electrical Inspections Electrical Service Meter -(Meter will be set within 2-3 business days after approval) Excludes New Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mec.) Grease Interceptor (Do not backfill unless qicnpd off I Sewer 1212 12 P Water Engineering Backflow (Testable Only) Water Service RICK BOUTROS, PE C57136 April 18, 2020 STRUCTURAL OBSERVATION Attn: Kurt Armstrong, Btulding Inspector SABIECT: 954 S. Canon Heiahts Dr.. Anaheim. CA PERMIT # BLD2018-02322 I, Rick Boutros, PE, observed and examined the following structural elements at the above address and verified all the comments on the Correction Notice dated 3/23/20W,, a6 concerned items have been corrected. The second floor shear nailing and roof framing, roof sheathing, roof diaphragm nailing strap at top plates notched/bored, girder truss solid framing underneath and bottom plate breaks are supported. Truss book is available onsite. Based on my observation, all the structural components are. structurally sound and all meet current code requirements. Respectfully, it n CZIP 75 Rick Boutros, PE C57136 Orange, CA Scanned with CamScanner a= PublicWorks Structural Observation Program Designation of Structural Observation PROJECT ADDRESS: q54 atmga) Y5M{i5 l�RnrE PERMIT APPL. NO. Description of Work: Ow 9,W.LF 'Qeip&xE Owner. Architect: J,GISMBL AAr&rzTS Engineer: _7&_* STRUCTURAL OBSERVATION (Only checked items are required) Firm or individual to be responsible for the Structural Observation: Name: 5 Phone: I ) Calif. Registration; $} 3la FOUNDATION WALL FRAME DIAPHRAGM Footing, Stem Walls, Piers Concrete Steel Moment Frame Concrete Mat Foundation Masonry Steel Bmccd Frame Steel Deck Caisson, Piles, Grade Beams Wood Concrete Moment Frame Wood Stepp'g/Retaining Foundation, Hillside Special Anchors Others: Masonry Wall Frame Others: The structure is classified as Occupancy Category HI or TV. The Height of the structure is greater then 75 feet (22,860 mm) above die base. The structure is assigned to Seismic Design Category E, is classified as Occupancy Category 1 or 11. %nitt�Mt DECLARATION BY OWNER 1, the Owner of the project, declare that the above listed firm or individ 5 TUCH is hired by me to be the Structurel Observer. SCSF 9 77649 Signature Date Declaration by Engineer or Architect of Record (required if different from the listed Structural Observer) 1, the Engineer or Architect of record for the project, declare that the above listed firm or individual is designated by me to be responsible for the Structural Observation. Signature 300 06w Street, Santa Ana, CA 92703 P.O. Box 4048, Santa Ana, CA 927024048 Revised 10/2015 Date n-13-2Wy C/VIL www. ocplannirig. riet P:714.667.8888 I F: 714.667.8885 ocpCustwnerCare@ocpw. ocgov. can TUCHSCHER ENGINEERING GROUP, INC 5318 E. 2ND STREET, #539 LONG BEACH. CA 90803 p: 310.613.9980 is r .TEGLosAngeles.com FIELD REVISION #5 REVISED POST BEAM CONNECTION HOMoHEIGHTS DRIVE ENRESIDENCE954 F5-Sl ANAHEIM, CA 92808 JOB 7-18-1408 SHEET NO. 1 OF 1 DRAWN BY RR DRAWING DATE 6/26/19 �Fc s Gw0 W TUCHSCHER ENGINEERING GROUP, INC 5318 E. 2N0 STREET. #539 LONG BEACH, CA 90803 p: 310. 613,9980 i. .w TFGI.,Angeles com (E) CURB WHERE OCCURS) (E) SLAB (E) FOOTING, JOB 7-18-1408 SHEET NO. 2 OF 2 DRAWN BY RR DRAWING DATE 6/25/19 (E) STUD (N) SOLID CONTINUOUS 2x4 MIN. BLOCKING, BETWEEN STUDS (3) 1/4 °Ox2 r211 SDS SCREWS BLOCKING, TO PLATE EXTEND ANCHOR BOLT TO TOP OF BLOCKING, UTILIZE COUPLER AND FI554 GRADE 36 THREADED ROD IF NECESSARY (E) ANCHOR BOLT SOLE PLATE BLOCKING RETROFIT HOMEN RESIDENCE 954 CANYON HEIGHTS DRIVE F4-S2 '� C' I ANAHEIM, CA 92808 oFcni R TUCHSCHER ENGINEERING GROUP, INC JOB 7-18-1408 5318 E. 2ND STREET,$539 SHEET NO. 1 OF 2 LONG BEACH, CA 90803 p: 310,613.9980 DRAWN BY RR I_ ., TEGto,Angel, com DRAWING DATE 6/25/19 NAIL TO TOP FACE OF TC- - • �- TOP 4x PSL/LSL BLOCKIt'� TOP PLATE FIELD REVISION #4 OPTION I OPTION 2 PER PLAN 'ER PLAN ' TO BOTTOM FACE OF BEAM PER PLAN 'ER PLAN 14 CLIPS BLOCKING PLATE BEAM TO TOP PLATE STRAP DETAIL HOMEN RESIDENCE F4-S 1 954 CANYON HEIGHTS DRIVE ANAHEIM, CA 92808 c OF CAI