420 N WEDGEWOOD DRPermit Types
BLD
ELE
MEG
PLM
X
Permit Number: BLD2024-05533
Issued: 10/16/2024
www.anaheim. net/bu ilding
(714)765-4626
Quarter Section: 62
CITY OF ANAHEIM
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714)765. 5153
Site Address: 420 N WEDGEWOOD DR, ANAHEIM, CA 92801
Legal Description: N TR 1833 BLK LOT 24
APN: 03437206
a
Project Description: Reroof: To remove and install (8) squares of flat
roof torch down over flat area only of the house.
Living Area: Number of Stories:
t Valuation: 8,350.00
Garage Area:
Construction Types: VB
Carport Area:
Omupancy Groups:
Balcony I Deck Area:
Fire Sprinklered:
Cool Roof:
Total Fee. peld for Permit: 360.09
People Associated with Project:
Contractor RON PAVELOFF ROOFING
5142 LAKEVIEW AVE200211121437375000 YORBA LINDA, CA 92886
Permit Applicant Ronald Pavelaff
Owner POULSEN, WALTER B TR THE
420 N WEDGEWOOD DR
Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures Qty
The permit shall expire by limitation and become null and void if the building or work has not passed final Inspection 365 days from the
date of permit issuance. A new permit Is required to commence or continue work.
PNFHEIM �.qC
City of Anaheim D4 iO
Building Division F i
u s
�OVNDED Lary^
Do not occupy this building until the final inspections have been made.
FINAL INSPECTIONS
DATE
INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
INSPECTION
I DATE
I INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pour concrete until the following applicable items have been signed:
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 765-4591
Electrical Ground Electrode/Ufer
Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days)
Setback/Forms/Trenches (Footings)
COA/Migation Measures
Do not install subfloor or pour floor slab until the follwing applicable items have been
sianed
Building Final (714765.5153)
Last Inspection -Final Only After Above Completed
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Building Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
Floor (Joist/Girders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
been sioned
1st Floor Shear
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
Roof(Sheathing/Diaphragm/Frame)
nn
�V n�ii
�yv
lu to
Masonry (Reinf./Bond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough COA/Mitagation Measures
Plumbing Inspections
Framing (Only after Plbg_. Ele., Mec. 8 Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter -(Meter will be set within 2-3
business days after approval) Excludes New
Construct on
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele., or Mec.)
Grease Interceptor
Sewer
Water Engineering Backflow (Testable Only)
Water Service
MEW BUILDING DIVISION
CITY OF ANAHEIM
BUILDING DEPARTMENT 2016 CALIFORNIA CODES
200 S. Anaheim Blvd., Suite 145 CODECY=
Anaheim, CA 92805 Ol/01/2017
DATE
714 765-5153 EFF£CTN
w .anaheim.net/building
SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION
Final inspection approval will require this completed form to be on site ales nth the job card.
Permit Number: 2�J, —'33 Date:
Project address: 4%
Property Owner: POU LS9:J FEs1605X-E
The undersigned does hereby certify that I am the property owner of the above referenced
property. I further certify that smoke alarms and carbon monoxide alarms are present and
/functional in all the following locations. All boxes must be checked below
la Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate
sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms.
U Smoke Alarms: In each room used for sleeping purposes.
❑ Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement;
(Note: in dwellings or dwelling units with split levels and without an intervening door between
the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level
shall suffice for the adjacent lower level provided that the lower level is less than one full story
below the upper level.)
All dwellin nits witKatta II'ed garages require carbon monoxide detector .
Signature: ��� U�� Date:
California Residential Code (CRC) Section R314.6.2,CRC R315.2 states in part that existing dwellings be
"retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or
in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as
indicted above.
NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim
Inspector is not achieved during the course of project construction. It is normally used for exterior projects such
as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work.
200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax FEB 2018
w .anaheim.net/building B842
SMOKE/ CO ALARM REQUIRED LOCATIONS
Bedroom Bedroom
6
Kitchen
Living Room
Figure 1
Family Room
Bedroom
Dining
Living
Room
Kitchen
Bedroom
Bedroom
v
Figure 2
Figure 3
REQUIRED SMOKE ALARM LOCATION
lye/ REQUIRED CARBON MONOXIDE ALARM LOCATION
4'
Acceptable Never-�
Here
Here
Top of Detector
Acceptable Here
♦'
T+r
Wen