888 S DISNEYLAND DR (37)Permit Types LLD ELE MEC PLM X XI X I X Permit Number: BLD2017-04611 Issued: 10/12/2017 INSPECTION REQUEST LINE: (714) 765 - 4626 Quarter Section: 74 Site Address: 888 S DISNEYLAND DR Legal Description: CITY OF ANAHEIM BUILDING DIVISION 200 S. ANAHEIM BLVD. (714) 765 - 5153 Project Description: Tenant Improvement: 3,722 sq.ft. renovation to include constructing (2) temporary mock up hotel suites (1 Double Queen and 1 King suite). These suites are not for rental - for testing only. Plbg/mech not intended for actual use. Demonstration only, per narrative on cover sheet. Construct 178 sq.ft. of balcony. REF: BLD2017-02015 Number of Stories 5 Valuation: $15,000.00 Construcion Types: IA, Occupancy Groups: B. , , , Fire Sprinklered? Yes Cool Roof No Total Fees paid for Permit: 1.457.95 People Associated with Project Owner 888 MILAN R E LLC %CLAUS DIECKELL 888 S DISNEYLAND DR #101 ANAHEIM CA 9 Engineer YEUK-HIN CHAN 888 S FIGUEROA STREET LOS ANGELES CA 90017 Engineer ALBERT H SAVANO 601 SOUTH FIGUEROA STREET SUITE 500 LOS ANGELES CA 900 Engineer DONGHUI XU 707 WILSHIRE BLVD 23RD FLOOR LOS ANGELES CA 90017 Engineer JALPAN SONI 707 WILSHIRE BLVD 23RD FLOOR LOS ANGELES CA 90017 Contractor K C S WEST INC 250 E 1ST ST 600 LOS ANGELES CA 90012 Permit Applicant MICHAEL MILLER Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Type Mechanical Fixtures Qty Receptacle, switches, lights 95 Bath Tub 1 Heating Appliances, including vent 2 Shower 1 Compressor/Boiler - over 15 hp 2 Lavatory 3 V. A. V. Unit 1 Floor Drain 1 Commercial Systems per 1,000 sq It 1 Fire/ Smoke Dampers 2 The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit issuance. A new permit is required to commence or continue work. :.a,,i combo ra NIAElbf C4 Cityof Anaheim C o� iO Building Division ti i u > ell tey^ LADED Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS DATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final-- "�-� Mechanical Final `f'%(: —�' t n V Cross Connection Control (714) 765-42bp _! p ',� Cv r ,�i C i C Engineering Final (714) 765.5126 INSPECTION DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 765-5044-,,7(1 Do not pour concrete until the following applicable items have been signed. Fire Dept. Final (714) 7655041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765-4591 Electrical Ground Electrode/Ufer Sub List/Bus, Lic. (714) 765-5194 (Allow 10 business days) Setback/Formslrrenches (Footings) COA/Migation Measures Do not install subfloor or pour floor slab until the follwing applicable Hems have been sian Building Final (714 765.5153) Last Inspection -Final Only After Above Completed Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre -slab (Compaction/Membrane Reinf.) Floor (Joist7Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not covEr or , al the work telow until that f ,Mowing applicable items have ,e n " nn i 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical 3 •Ib'" Rough Electrical *1 Rough COA/Mitagation Measures Plumbing Inspections Framing (Only after Plbq Flu Mec h F,,u; Insulation (Sound/Energy) Q Do not tape or plaster until the folk mg apphcabe dems hay bee signed Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter -(Meter will be set within 2-3 business days after approval) Excludes New Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mec.) Grease Interceptor Sewer Water Engineering Backflow (Testable Only) Water Service