323 S PERLATA HILLS DRCity of Anaheim BUILDING DIVISION INSPECTION RECORD SWIMMING POOL ADDRESS: 332 S PERALTA HILLS DR OWNER: PERMIT#: SW12018-00087 DATE ISSUED: a/14/2018 DESCRIPTION: New Pool and Spa: 921 sf. in ground gunite pool, reef, and 68 A in ground gunite spa. POST THIS CARD WITH THE APPROVED PLANS IN A CONSPICUOUS PLACE ON THE JOB SITE Inspection Code D to Inspector 1. Main Outlet. 504 dtAB4 jAootw*:4 2. Electric Bonding. 506 i A W-1 3. Steel. 508 t 4. Approval to Gunite. 510 DO NOT GUNITE POOL/SPA until all the above inspections have been signed. 5. Steel and bonding. 1 508 DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until all the above inspections ha tiqlan signed. 6. Underground elect. 512 1 a 7. Gas piping test. 514 T J 06 ,i 8. P-Trap Receptor. 516 y a � 9. Backflow Device. 518 AA 1I 10. Deck, Deck Drains, & accessory bonding.DO 520 �( 16RK ,AU0bW__1 NOT POUR FL until the above inspections have b en Aigned. 11. Rough electric. 522 12.Fencing. 524 IJ=% i j D _) 13. Plaster approval. 526 1 j 2,3 LW DO NOT PLAS until the a v in a ions have been sioned. 14. Final Electric. 528 Sub -Contractors list approved and pool cover in place prior to final nspectIon. 16. FINAL 599 avks MISC. INSPECTIONS DATE INSPECTOR Inspectors can normally be reached between 7:30 - 8:00 A.M. and 3:30 - 4:30 P.M. (714) 765-5153 + 0 Inspections 1 - 5: 1. All plumbing to be complete and the system pressurized to 35 lbs. with water or house pressure. 2. All metal within 5 feet of pool water, and all pool equipment, must be bonded to pool reinforcing steel with #8 solid copper wire. Niche light shell, deck inserts, etc., shall be bonded to pool rebar. 3. Pool equipment is not required to be set at this time. Inspections 6 -10: 1. Underground electric inspected prior to backfilling. 2. Gas line test at 10# for 15 minutes, with 15# gauge. 3. When polyethylene gas piping is used, a certificate from a certified installer and a metal tag at the meter shall be provided per CPC 1211.3 APPENDIX I. Inspections 11 -13: 1. Rough electric inspection when all wiring is completed and ready to run prior to the plastering of pool/spa. y 2. City ordinance 6.56.010 requires that any pool, spa / or water feature containing water 18 inches or more in depth shall be enclosed by a barrier adequate to prevent entry of small children. The barrier shall comply with Section 421 of the current CBC and City of Anaheim ordinance 15.02.060.180 specifying the height of any fence provided as barrier to the pool shall be 60" above grade on the outside of the fence. 3. Doors from a garage shall meet the requirements for a gate. Glass windows within 5' of pool water shall be tempered glass. 4. Prior to pre -plaster inspection, streets, curbs and city sidewalks will be inspected for any damage due to construction of pool or spas. 5. Grading complete with positive drainage to street or public way. All exposed plastic pipe painted to protect from sunlight. Inspections 14 - IS: 1. After pool is operating and in working condition, approved pool cover in place. INSPECTION REQUESTS Inspection requests made before 5:00 pm will be scheduled on the following workday. To schedule your building inspection online, please go to http://www.anaheim.neVinspectionReguest. You may also request your inspection by calling (714) 765-4626 and continue with the following steps: • Press 1 for inspection function. • Press 1 to schedule inspection. • Press 5 for Swimming Pool inspection. • Enter your permit # 201800087. • Enter the Code number for the inspection requested (indicated in blue). • Press 1 for next business day, or enter date preferred. • Select time preference (Request is subject to inspector's schedule.) To access your inspection timeframe, please go to www.anaheim.net/buildinq after 7:30 am on the day of your inspection. Under Online Services, click on the "Inspection Timeframes" link or call (714) 765-5153 4 0. swin,card SOILS AND GEOLOGY GROUP Soils Engineering • Engineering Geology 17231 EAST RAILROAD STREET, SUITE 200, CITY OF INDUSTRY, CA 91748 TELEPHONE (626) 964.2314 FAX (626) 965-3802 NOTICE OF %DOG �eA✓ATJplV INSPECTION JOB LOCATION 33Z S• P¢va114 /J;)I1 gzl. JOB NO. Jb`41 DATE OF INSPECTION 7 /—JS CLIENVOWNER L-v!�4 CLIENT'S ADDRESS DESCRIPTION OF AREA INSPECTED:L /e/osr.Izs�y Y, f � Q✓LG� /J ✓YcUG>!4-1�4 ?'�`�-¢�f14✓7Si!/1. A gi.� j.n ,CGGay /GHG�- W• Fh /lu- 'euU¢ s'I/IU(i/lam' �� �)�brvYLU• 7-A-e- 2-2PsXvA'/4Ph 1S /`G � �Ir OTECHNICAL ran ITI No GE805 JOB SUPERINTENDENT: INSPECTED BY a-so_7 SIGNATURE SIGNATURE