CITY OF ANAHEIM
BUILDING DIVISION
Permit Number: BLD2024-02443 200 S. ANAHEIM BLVD.
Issued: 05/28/2024 (714) 765 - 6153
www.anaheim.net/building
(714)765-4626 �1 Q
Quarter Section: 113 V
Site Address: 391 S SUNKIST ST 1-6, ANAHEIM, CA 92806
Legal Description: P BK 150 PG 48 PAR 1 P.M. 150-48 PAR. 1 AN PO
APN:08373118
Project Description: New Residential Construction: 10,866 sf. to construct (6) 3-story attached townhomes with 2,826 sf. of attached
garages, 40 sq. ft. for porch and 612 sq. ft. for decks. Install roof mounted solar. REF: TRACT2023-00001 (Tract 19237).
Building Type E
(2) 1,771 sf. 4bd/3.5bths (Plan Type 4)
(2) 1,827 sf. 4bd/3.5bths (Plan Type 5A)
(1) 1,835 St. 4bd/3.5bths (Plan Type 5B)
(1) 1,835 sf. 4bd/3.5bths (plan Type 5C)
Living Area:
Garage Area:
Carport Area:
Balcony I Deck Area:
Cool Roof:
10866 Number of Stories:
2826
612
3 Valuation:
Construction Types:
Occupancy Groups:
Fire Spnnklered:
Total Fees paid for Pannell:
1,000,000.00
VB
U1, Ut, U1, R3, R3, R3, R3, Ul. R3, Ul, R3
100,357.86
People Associated with Project:
Contractor KB HOME COASTAL INC
10990 WILSHIRE BLVD SUITE 700,LEGAL DEPT LEGAL DEPT 199911160813085820 LOS F
Permit Applicant Frank Chen
1 Technology Building I, Suite 801
Irvine, CA 92618
Owner KS HOME COASTAL INC
36310 INLAND VALLEY DR N300
Type Electrical Fixtures
Qty
Type
Plumbing Fixtures Qty
Mechanical Fixtures
Qty
Meter/Disc Sw - Under 600 V, over 500
1
Bath Tub
12
Compressor/Boiler- up to 15 hp
6
amps to 1000 amps
Dishwasher
6
Condenser
6
Meter/Disc Sw - Under 600 V. up to 200
7
6
Heating Appliances, including vent
6
Garbage Disposal
amps
Heating/Cooling Coil
6
Microinverter
60
Kitchen Sink
6
Residential Registers (duds)
154
Motors - Factory Wired Appliance, up to 1
6
Lavatory
30
Ventilation Fan - <= 300 cfm on single dud
36
h.p.
New or total rewire -garage/carpoA
2826epair/Drainage
Alteration/Vent Piping 1
R
New or total rewire - mufti -family
10866
Sewer per 100 ft.
1
Sub Panel/Temp Pwr - Under 600 V, up to
13
Shower
6
200 amps
Washing Machine
Rough 6
Water Closet
24
Water Distribution 1
Water Heater 6
Water Main per 100 ft.
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the
date of permit Issuance. A new permit is required to commence or continue work.
Par,HglM �q<
Cityof Anaheim OF iO
Building Division h z
v '
Do not occupy this building until the final inspections have been made.
FINAL INSPECTIONS
DATE
INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
r1-4
of
Plumbing Final
r217-Lf
'w',ii
Mechanical Final
t•LT-2
N [!..-. -
Cross Connection Control (714) 765.4280
Engineering Final (714) 765-5126
INSPECTION I
DATE I
INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pour concrete until the following applicable items have been signed:
Fire Dept. Final (714) 765.5041
Plumbing (Ground/Underfloor Drain Waste)
61,.12.q
►-N
Water Engineering (714) 765-4591
Electrical Ground ElectrodelUfer
61211 2
ii&,
Sub List/Bus. Lic. (714) 766.5194 (Allow 10 business days)
SetbacklFormslTrenches (Footings)
1, 2l Q„
K•
COAIMigation Measures
Do not install subfloor or pour floor slab until the follwing applicable items have been
sian d:
Building Final (714765-5153)
Last Inspection -Final Only After Above Completed
r1-Z7-Zy
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Building Inspections
- rd- Iabr ij"( _u-
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
46 L2q
axiel
Floor (JoisUGirders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing) 1 fZ
Do not cover or conceal the work below unh the ollowing app icable items have
been sioned
1st Floor Shear
IZ 4
Z.Nl
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
y i
mtA
Roof (SheathinglDiaphragmlFrame)
^---1
Masonry (Reinf.lBond Beam/Pre-Grout)
Rough Plumbing (Top out)
9 11 ty
'-At-1
Rough Duct (Mechanical)
°( t 1,
�h
Rough Mechanical
Rough Electrical
Rough COAIMitagation Measures
Plumbing Inspections
Framing (Only after Plbg., Ele., Mec. & Fire)
at ti
7yt
or1,( ,
Insulation (SoundlEnergy)
9 (it 29
4
1 - tote;
Do not tape or plaster until the following applicable items have been signed
Drywall
J Nt
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
s
JAB.
Electrical Inspections
7ePyoNtyµ t1124
Electrical Service Meter -(Meter will be set within 2-3
business days after approval) Excludes New
Construction
I' Ill
I
r
Exterior Plaster (Brown Coat)
V 2
OA"
T-Bar (Struct., Ele., or Mec.)
Grease Interceptor
Sewer
lb 9
J
Water Engineering Backflow (Testable Only)
Water Service