996 S SILVER STAR WAYPermit Types BLD ELE MEC PLM X Permit Number: BLD2024-04607 Issued: 09103/2024 virvirvicanaheirn.net/building (714)765-0626 Quarter Section: 227 CITY OF ANAHEIM BUILDING DIVISION 200 S. ANAHEIM BLVD. 4714) 765 -5153 Site Address: 996 S SILVER STAR WAY, ANAHEIM, CA 92808 Legal Description: N TR 14191 BLK LOT 19 APN: 35447150:, Project Description: Retool: Tile relay over existing layer (19) sq of heavyweight Tile over the entire house and attached garage Living Area: Number of Stones: 1 Valuation: 10,000.00 Garage Area', Construction Types: NIA Carpon Area: Occupancy Groups: Balcony I Deck Area: Fire Spnnklered: Cool Roof: Total Fees paid for Permit: 495.30 People Associated with Project: Contractor ROOFTEK & WATERPROOFING SYSTEM 2440 N GLASSELL ST SUITE U ORANGE, CA 92865 Permit Applicant Tomas Macedo 2440 N Glassell St Suite U Orange, CA 92865 Owner WONG, MARK & DAISY 996 S SILVER STAR WAY t Type Electrical Fixtures City Type Plumbing Fixtures Qty Mechanical Fixtures Qty The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit Issuance. A new permit is required to commence or continue work. PHEIM �dC Cityof Anaheim DF iO Building Division ' Z D > - O(/NOED vsh^ Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS DATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714) 765-4280 Engineering Final (714) 765-5126 INSPECTION I DATE INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been signed: Fire Dept. Final (714) 765-5041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765-4591 Electrical Ground Electrode/Lifer Sub Lisf/Bus. Lic. (714) 765-5194 (Allow 10 business days) Setback/FormslTrenches (Footings) COA/Migation Measures Do not install subfloor or pour floor slab until the follwing applicable items have been sioned Building Final (714 765-6153) Last Inspection -Final Only After Above Completed Plumbing (GroundlUnderfloorWater) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre -slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been sioned list Floor Shear Firesprinkler(Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) ►✓1 Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbing Inspections Framing (Only after Plbg.. Ele , Mec. & Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed. Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter -(Meter will be set within 2-3 business days after approval) Excludes New Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mec.) Grease Interceptor Sewer Water Engineering Backflow (Testable Only) Water Service _ 2207 Merced Ave iDDARY ENGINEERING South ElM`213)291-0778 mail@daryengineering.com ROOF REPORT Client: SEP 0 2 2024 Rooftek & Waterproofing Systems 2440 N. Glassell St. Suite U. BUILDING DIVISION OF Orange, CA 92865 APPROVE Phone: (714) 904-4759 Sa Subject: Remove and Reuse (E) concrete tile to provide new(Fe"ool August 30, 2024 ect Address: S. Silver Star Way ieim. CA 92808 Underlayment. Pursuant to your request, we have reviewed the roof framing of the structure at the above address for structural adequacy to accommodate the proposed roofing material. The house is conventionally framed. Existing building summary: Use of Building = Single -Family Building Area = 2,017 S.F. Year Built = 1991 Construction Type= Type VB Existing roof System: Roof pitch of 5:12 and appears to be in sound condition. Standard weight concrete tile @ 9.7 psf IAMPO #1900 %" CDX plywood sheathing 2x6 Rf. Rafters @24" O.C. max. span 10'-0" 2x10 Hip Rafters max. span 9'-0" 6x14 Ceiling beam max. span 21'-0" 2x4 Manufactured Truss @24" O.C. max. span 30'-0" Proposed new roofing materials: New 30# ASTM Felt Roofing Underlayment. Design Loads: DL= 15 psf LL= 20 psf C056295 �EXp.DEC. 2024 / OF Existing concrete tiles are being removed and reused to provide new felt roofing underlayment. No increase in dead loads. In addition, calculations show that existing roof framing members are adequate to support the existing concrete tile, it is therefore, our opinion that re -roofing with same concrete tile will not compromise the structural integrity of the roof system at the above -named project address. The determination of the roof's structural integrity is based on visual observation and known mechanical properties of wood. After re -roofing, a small amount of deflection in the rafters may be observed. This condition is cosmetic and should not affect the structural integrity of the roof framing. Instructions to Roofer: 1. Remove and replace any damaged plywood sheathing prior to placement of new 301bs underlayment felt paper. 996 S. Silver Star Way. Anaheim Hills Job No. 814-24 v�mT T 1 9 I m N 03 ------T--- r-------------- -'1------, 31 M I Z I 5 R. a i °h 10 O.C. 10 .0 I�I m T L : 21' r �� ............. 2ND. LOOR LN. D D PRWECTACRESS'. �� 8 Re -Roofing gN'p 996 WEUS. ESilver Star Way Anaheim, CA 92808 g Affix (E) ROOF FRAMING PLAN �1�/ r ,m � _n r p N A cn n D r N M z w w 0 z o 0 D M iF rn N N A x OA v n� m m � V C J) Q PMECTAPESS: Re-Roofing�� N r * 996 A ESilver Star Way Anaheim, CA 92808 SHEE7m TYPICAL SECTION A a , N 1 _ DARY ENGINEERING 2207 Merced Avenue ■ South El Monte, CA 91733 213.291-0778 213-725.8011 Mall®daryenoln eering.con Proiect Information Project Title : 996 S. Silver Star Way Description : Remove and Reuse Existing Concrete tile I.D. : 814-24 Address : 996 S. Silver Star Way, Anaheim, CA 92808 Project Leader : Dias Yassin Phone : 213-291-0778 Project Notes Fax :213-725-8011 Project Title: 996 S. Silver Star Way Engineer: Dias Yassin Project ID: 814-24 Project Descr: Remove and Reuse Existing Concrete tile Printed: 30 AUG 2024. 3:45PM eMail : Mail@daryengineering.com hRROFESSIpNq\ y J � y � No. C056295 Exp.DEC. 2024 J,TgTF CIVIL OF C A�� BUILDING DIVISION CITY OF ANAHEIM BUILDING DEPARTMENT 2016 CALIFORNIA CODES 200 S. Anaheim Blvd., Suite 145 com cr= Anaheim, CA 92605 01/01/2017 714 765-5153 a FECTVSDAa www.anaheim.net/building SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION " Final inspection approval will require this completed form to be on site along with the job card. Permit Number: Date: (Z io 1 2 Project address: R96 S stlJV- CjkrA\- R-M Property Owner: V 1(NY t' The undersigned does hereby ce ify that I am the property owner of the above referenced property. I further certify that smoke alarms and carbon monoxide alarms are present and functional in all the following locations. All boxes must be checked below IA/ Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms. SSmoke Alarms: In each room used for sleeping purposes. 9' Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement; (Note: in dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.) All dwelling u tss,with %attached garages require carbon monoxide detectors. ure: � Signat�/X / Date: I Z Z California Residential Cotje (CRC) Section R314.6.2,CRC R315.2 states in part that existing dwellings be "retrofitted with smoke deti6ctors and carbon monoxide detectors when a building permit is issued for work on or in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as indicted above. NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim Inspector is not achieved during the course of project construction. It is normally used for exterior projects such as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work. 200 S.. aheim Blvd., Suite 145 Anaheim, Califomia 92805 (714)765-5153 Phone (714)765-4607 Fax FEB 2018 www.anaheim.nei1building B842 SMOKE/ CO ALARM REQUIRED LOCATIONS Bedroom Bedroom 6 Bat Bedroom Kitchen Living Room 1:n Figure 1 6 Bedroom Living Room Attic 6 co Hall L Hall 4600 Basement Family Room Bedroom WD Dining Living Room Kitchen 6 1 46 Bedroom Bedroom Figure 2 6 Bedroom Kitchen Figure 3 REQUIRED SMOKE ALARM LOCATION REQUIRED CARBON MONOXIDE ALARM LOCATION 4- Acceptable -J 4 Here Never � Here-Ir rx Top of Detector Acceptable Here ] j Wall Figure 4 Garage