Loading...
511 S FAIRMONT CIRPermit Types BLD 0 ELE MEC PLM X Permit Number: BL02024-06011 Issued: 11/14/2024 www.anaheim.nettbuilding (714)765-4626 Quarter Section: 210 Site Address: 511 S FAIRMONT CIR, ANAHEIM, CA 92807 Legal Description: N TR 8463 BLK LOT 2 APN: 36528103 CITY OF ANAHEIM BUILDING DIVISION 200 S. ANAHEIM BLVD. (7141765 - 5153 Project Description: Reroof: Remove and install (34) sq of lightweight tile over the entire house and attached garage Living Area: Number of Stones: 1 valuation: Garage Area: Construction Types: Carport Meat Occupancy Groups: Balcony I Deck Area: Fire Sprinklers& Cool Roof: Total Fees paid for Permit: People Associated with Project: Contractor CASSADY ROOFING INC 13021 LAKELAND ROAD SANTA FE SPRINGS, CA 90670 Permit Applicant Madison Rafuson Owner MELEIKA, WADEED S TR 511 S FAIRMONT CIR 28,000.00 WA 754.64 Type Electrical Fixtures Qty Type Plumbing Fixtures Qty, Mechanical Fixtures Qty The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit issuance. A new permit Is required to commence or continue work. PApHE 114 pq< City of An a h e i m OQ iO Building Division i u a �OVNDEO t85^ Do not occupy this buildina until the final inspections have been made. FINAL INSPECTIONS DATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714) 765-4280 Engineering Final (714) 765-5126 INSPECTION I DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been signed: Fire Dept. Final (714) 765.6041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765.4591 Electrical Ground ElectrodelUfer Sub List/Bus. Lic. (714) 765-6194 (Allow 10 business days) SetbacklFormslTrenches (Footings) COAIMigation Measures Do not install subfloor or pour floor slab until the follwing applicable items have been sianed Building Final (714765-5153) Last Inspection -Final Only After Above Completed Plumbing(GroundlUnderfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre -slab (CompactionlMembrane Reinf.) Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been sianed 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) Masonry (Reinf.lBond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COAIMitagation Measures Plumbing Inspections Framing (Only after Plbg., Ele., Mec. & Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter -(Meter will be set within 2-3 business days after approval) Excludes New Construction Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mec.) Grease Interceptor (Do not backfill unless Sro ned off) Sewer Water Engineering Backflow (Testable Only) Water Service CITY OF ANAHEIM 2016 CALIFORNIA CODES BUILDING DEPARTMENT CODECYCLE 200 S. Anaheim Blvd., Suite 145 01/01/2017 Anaheim, CA 92805 EFFEMVEDATE 714 765-5153 w .anaheim.net/building SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION ` Final inspection approval will require this completed form to be on site along with the job card. _ Permit Number: D(oQJI Date: 19-1;20aq Project address: !�211 S /% 2h Oif Property Owner: / The undersigned does hereby certify that I am the property owner of the above referenced property. I further certify that smoke alarms and carbon monoxide alarms are present and functional in all the following locations. All boxes must be checked below Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate //sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms. Y mokeAlarms: In each room used for sleeping purposes. moke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement; (Note: in dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.) All dwelling units with attached gaffes require carbon monoxide detectors. Signature: California Residential Code (CRC) Section R314.6.2,CRC R315.2 states in part that existing dwellings be "retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as indicted above. NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim Inspector is not achieved during the course of project construction. It is normally used for exterior projects such as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work. 200 S. Anaheim Blvd., Suite 145 Anaheim, Califomia 92805 (714)765-5153 Phone (714)765-4607 Fax 20t8 �.anaheim.net/bullding B842 SMOKE/ CO ALARM REQUIRED LOCATIONS Bedroom Bedroom 6 Bath V Bedroom ca Kitchen Living Room E- Figure t 6 Bedroom Living Room Basement Family Room Bedroom qaq liD `\1 Dining Living Room Kitchen W q 6"U Bedroom Bedroom Figure 2 6 Bedroom Kitchen Figure 3 REQUIRED SMOKE ALARM LOCATION REQUIRED CARBON MONOXIDE ALARM LOCATION a• Acceptable J °• Here Never Here 711• Top of Detector AcceptaNe Here Garage Figure 4 The following table provides a summary of the preceeding analysis and indicates which members (if any) require further field verification or strengthening. When strengthening is required, refer to the Roof Plan (and associated details when applicable) in this report for specific information about the strengthening measures required for this project. Any required strengthning shall be completed prior to the installation of any new roof loads. Refer to the Terms and Conditions section of this report for additional information about the means and methods of construction. ANALYSIS SUMMARY Member ID IS Field Verification by Contractor Required? IS Strengthening Required? 11 No No J2 No No 1; No No at No No 82 No No SEAL AND SIGNATURE The preceding structural analysis has been performed by Regal Structural Group expressly for the project located at 511 Fairmont Cir in Anaheim, California. The analysis and recommendations are based on the as -built conditions at the time of the structural survey noted in this report. Any alterations or modifications to the existing roof structure after the survey date have not been taken Into account. If any modifications have occurred, further investigation and analysis Would be required prior to implementing any reroofing or strengthening. 20!'f C November 11, 2024 Nick Murph P.E. I Ma aging Principal DATE 'ty�`Sx0u AS ,yf/ r F, ?` e s No 71800 Exy IWI125 '- Aviv _.P! Regal Structural Group Birch Street #282 Newport CA oR EGAL regfgcucctro,gR.com STRUCTURAL GROU P p: 949."1."98 e: roofsQgregalrtructuralgmup.com r r I I i J1 J1 VAULTED 1 ------------ --------1- r r 1 I � ' Jl r r J1 t I * 7q I � t 1 1 -----------'- ------ ------�� O�(0 o i �._---_CAL_ i m I,FRM'G B2 ' RIDGE _____________ r ______________________ VAULTED (E) ASSUMED ROOF WEIGHT. Cemwood Shake Tiles=5S ps( NEW CLASS A ROOF: Eagle - Eagle Standard Weight (9.8psO [IAPMO ER-1900] Mark Existing Member Verj%q Strengthening "e )1 2x8@241n O.C. No No J2 2xB @ 24in D.C. No No J3 2XID@16in o.c Yes No B1 412 No No 82 416 Yes No Plan Notes: 1. THE ROOF SLOPE IS 5:12 (UNO). 2. ALL FRAMING INDICATED ON THIS PLAN IS EXISTING UNLESS NOTED OTHERWISE. 3. THE CONTRACTOR SHALL VERIFY THATTHE EXISTING FRAMING SIZE AND SPACING MATCHES THAT SHOWN ON THE ROOF PLAN. SHOULD THERE BE A DISCREPANCY, THE CONTRACTOR SHALL NOTIFYTHE ENGINEER IMMEDIATELY 50 THAT AN UPDATED REPORT CAN BE PROVIDED. 4. THE SPAN INDICATED IN PARENTHESIS IS THE MAXIMUM SPAN FOR THE FRAMING IN THE GIVEN BAY. SHOULD THE ACTUAL HORIZONTAL SPAN (NOT SLOPING SPAN) EXCEED THAT SHOWN, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SO THAT AN UPDATED REPORT CAN BE PROVIDED. 5. WHERE THE EXISTING FRAMING COULD NOT BE VERIFIED IN THE FIELD DUE TO LIMITED ACCESS OR WAS COVERED WITH FINISHES, IT IS NOTED WITH AN ASTERISK N. IN THESE INSTANCES THE CONTRACTOR SHALL VERIFY THE FRAMING AFTER THE EXISTING ROOF HAS BEEN REMOVED AND NOTIFY THE ENGINEER IF THE EXISTING FRAMING DOES NOT MEET OR EXCEED THAT WHICH IS INDICATED IN THE REPORT. 6. FRAMING SHOWN HAS NOT BEEN ANALYZED TO SUPPORT STORAGE LOADS. WHERE STORED REMS EXIST ABOVE THE EXISTING CEILING JOISTS, IT SHOULD EITHER BE REMOVED OR ELSE SPREAD OUT SO AS NOT TO EXCEED MORE THAN 5 POUNDS PER SQUARE FOOT. ** See Plan for Strengthening Requirements