Loading...
63-0808RESOLUTION NO. 63R-808 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ANAHEIM FINDING AND DETERMINING THAT THE PUBLIC INTEREST AND NECESSITY REQUIRE THE ACQUISITION, CONSTRUCTION AND COMPLETION OF A PUBLIC UTILITY EXTENSION AND PUBLIC IMPROVEMENT, CONSISTING OF ELECTRIC LIGHT, HEAT AND POWER LINES AND WORKS IN CERTAIN PORTIONS OF THE CITY OF ANAHEIM AND THE ACQUISITION THEREOF BY THE CITY OF ANAHEIM BY EMINENT DOMAIN PROCEEDINGS OF CERTAIN PROPERTY OF SOUTHERN CALIFORNIA EDISON COMPANY IN SAID CERTAIN PORTIONS OF SAID CITY. BE IT RESOLVED BY THE COUNCIL OF THE CITY. OF ANAHEIM: SECTION 1. It is hereby found and determined that the public interest and necessity require the acquisition, construction and completion of a public utility extension and public improvement, consisting of electric light, heat a power lines and works in the City of An helm ;s hereinafter more particularly described in the appendix attached hereto and by this reference made part hereof, to be used for and necessary for (1) the transmission and distribution of electricity for the purpose of furnishing and supplying electric light, he.t and power to the City of Anaheim and certain of the inhabitants thereof; and (2) the proper development and control of such use of such electricity, at this time, rand the future proper development and control thereof, as apart of the electrical system owned and operated by the City of Anaheim for furnishing and supplying electrical energy to said City and certain of the inhabitants thereof. SECTION 2. The public interest and necessity require the taking and acquisition by the City of Anaheim for said public utility extension and public improvement and use, of the electric light, heat and power distribution and communication system of the Southern California Edison Company located within said certain portions of the City of Anaheim, as shown on Appendix 1, Sheets 1 to 60, both inclusive, attached hereto, including: -1- ITEM 1 Poles and Fixtures 1 each Pole, wood, BT, 40 ft. 1 each Pole, wood, PT, 35 ft. (.50 interest) 1 each Pole, wood, PT, 45 ft. (.34 interest) 1 each Pole, wood, PT, 65 ft. (.34 interest) 1 each Pole, wood, PT, 35 ft. 1 each Pole, wood, PT, 45 ft. 1 each Pole, wood, PT, 50 ft. 4 each Pole, wood, TFL, 30 ft. (.50 interest) 15 each Pole, wood, TFL, 35 ft. (.50 interest) 1 each Pole, wood, TFL, 40 ft. (.34 interest) 38 each Pole, wood, TFL, 40 ft. (.50 interest) 26 each Pole, wood, TFL, 40 ft. (.60 interest) 1 each Pole, wood, TFL, 40 ft. (.65 interest) 61 each Pole, wood, TFL, 40 ft. (.67 interest) 1 each Pole, wood, TFL, 45 ft. (.26 interest) 7 each Pole, wood, TFL, 45 ft. (.33 interest) 2 each Pole, wood, TFL, 45 ft. (.34 interest) 2 each Pole, wood, TFL, 45 ft. (.50 interest) 40 each Pole, wood, TFL, 45 ft. (.60 interest) 23 each Pole, wood, TFL, 45 ft. (.65 interest) 43 each Pole, wood, TFL, 45 ft. (.67 interest) 1 each Pole, wood, TFL, 50 ft. (.31 interest) 5 each Pole, wood, TFL, 50 ft. (.33 interest) 6 each Pole, wood, TFL, 50 ft. (.34 interest) 8 each Pole, wood, TFL, 50 ft. (.50 interest) 2 each Pole, wood, TFL, 50 ft. (.55 interest) 6 each Pole, wood, TFL, 50 ft. (.65 interest) 15 each Pole, wood, TFL, 50 ft. (.66 interest) 15 each Pole, wood, TFL, 50 ft. (.67 interest) 1 each Pole, wood, TFL, 55 ft. (.17 interest) 2 each Pole, wood, TFL, 55 ft. (.20 interest) -2- 2 each Pole, wood, TFL, 55 ft. (.23 interest) 1 each Pole, wood, TFL, 55 ft. (.32 interest) 3 each Pole, wood, TFL, 55 ft. (.33 interest) 28 each Pole, wood, TFL, 55 ft. (.35 interest) 8 each Pole, wood, TFL, 55 ft. (.50 interest) 5 each Pole, wood, TFL, 55 ft. (.67 interest) 5 each Pole, wood, TFL, 55 ft. (.70 interest) 11 each Pole, wood, TFL, 60 ft. (.25 interest) 1 each Pole, wood, TFL, 60 ft. (.33 interest) 1 each Pole, wood, TFL, 60 ft. (.34 interest) 6 each Pole, wood, TFL, 60 ft. (.50 interest) 1 each Pole, wood, TFL, 60 ft. (.67 interest) 3 each Pole, wood, TFL, 65 ft. (.34 interest) 7 each Pole, wood, TFL, 65 ft. (.35 interest) 2 each Pole, wood, TFL, 65 ft. (.39 interest) 10 each Pole, wood, TFL, 65 ft. (.50 interest) 1 each Pole, wood, TFL, 65 ft. (.70 interest) 4 each Pole, wood, TFL, 70 ft. (.50 interest) 2 e ch Pole, wood, TFL, 75 ft. (.21 interest) 8 each Pole, wood, TFL, 75 ft. (.25 interest) 1 each Pole, wood, TFL, 80 ft. (.10 interest) 3 each Pole, wood, TFL, 80 ft. (.20 interest) 7 each Pole, wood, TFL, 80 ft. (.25 interest) 3 each Pole, wood, TFL, 80 ft. (.30 interest) 1 each Pole, wood, TFL, 80 ft. (.34 interest) 5 each Pole, wood, TFL, 80 ft. (.40 interest) 2 each Pole, wood, TFL, 80 ft. (.50 interest) 1 each Pole, wood, TFL, 80 ft. (.60 interest) 1 each Pole, wood, TFL, 85 ft. (.15 interest) 1 each Pole, wood, TFL, 85 ft. (.20 interest) 2 each Pole, wood, TFL, 85 ft. (.22 interest) 1 each Pole, wood, TFL, 85 ft. (.60 interest) -3- 1 each Pole, wood, TFL, 90 ft. (.17 interest) 11 each Pole, wood, TFL, 25 ft. 9 each Pole, wood, TFL, 30 ft. 20 each Pole, wood, TFL, 35 ft. 60 each Pole, wood, TFL, 40 ft. 106 each Pole, wood, TFL, 45 ft. 35 each Pole, wood, TFL, 50 ft. 2 each Pole, wood, TFL, 55 ft. 3 each Pole, wood, TFL, 60 ft. 1 each Pole, wood, TFL, 65 ft. 2 each Pole, wood, TFL, 70 ft. 54 each 28 each 466 each 165 each 9 each 146 each 43 each 112 each 36 each 4 each 1 each 66 each 4 each 3 each Crossarm Crossarm Crossarm Crossarm Crossarm Crossarm Crossarm Crossarm Crossarm Crossarm Crossarm Crossarm Crossarm Crossarm 112 each Guy, 1/4" aerial 10 each Guy, 5/16" aerial 2 each Guy, 7/16" aerial 237 each Guy, 5/16" down 12 each Guy, 7/16" down wood, single, Std. 80 wood, double, Std. 80 wood, single, Std. 82 wood, double, Std. 82 wood, triple, Std. 82 wood, single, Std. 83 wood, double, Std. 83 wood, single, Std. 86 wood, double, Std. 86 wood, triple, Std. 86 wood, single, Std. 99 wood, single, Std. 100 wood, double, Std. 100 wood, single, 12 ft. -4- 1 each Cuy, 5/16" sidewalk (.50 interest) 15 each Guy, 5/16" sidewalk 10 each Anchor, 15" plate and Std. 127 rod (.50 interest) 30 each Anchor, 20" plate and Std. 127 rod (.50 interest) 32 each Anchor, 20" plate and Std. 177 rod (.50 interest) 1 each Anchor, screw Type (.50 interest) 64 each Anchor, 15" plate and Std. 126 rod 43 e ch Anchor, 15" plate and Std. 127 rod 31 each Anchor, 20" plate and Std. 127 rod 3 each Anchor, 20" plate and Std. 128 rod 17 each Anchor, 20" plate and Std. 177 rod 1 each Anchor, screw type 190 each Cover, wood, guy wire, Std. 46 7 each Cover, metal, guy wire 2 each Brace, Smith Corner, Std. 62 34 each Brace, vertical, Std. 71 13 each Brace, alley arm, Std. 72 2 each Bracket, 2 -wire, Std. 158 15 each Bracket, 3 -wire, Std. 158 44 each Bracket, insulator, wye -bus, Std. 295 6 each Bracket, double arming 66 each Rack, service, Std. 283 284 each Rack, secondary, Std. 284 19 each Rack, service take -off, Std. 366 7 each Platform, transformer, 13 6" 2 each Extension, pole top, Std. 73 2 each Extension, crossarm, Std. 293 282 feet Conduit, 2" fibre 1 each Bend, 2" fibre 800 each Pin, wood, insulator, Std. 162 -5- 731 each Pin, steel, insulator, Std. 163 951 each Pin, steel, insulator, Std. 164 33 each Pin, steel, insulator, Std. 242 54 each Pin, steel, insulator, Std. 247 6 each Pin, steel, insulator, Std. 267 1,882 each Step, pole, Std. 34 820 each Strip, visibility, Std. 249 10 feet Steel, channel, 4" Overhead Conductors and Devices 86,470 feet Wire, No. 6 bare copper 21,120 feet Wire, No. 4 bare copper 300 feet Wire, No. 2 bare copper 69,885 feet Wire, 2/0 bare copper 1,290 feet Wire, No. 8 weatherproof copper 23,040 feet Wire, No. 6 weatherproof copper 9,690 feet Wire, No. 4 weatherproof copper 1,740 feet Wire, No. 2 weatherproof copper 175 feet Wire, 2/0 weatherproof copper 772 each Insulator, pin type, Std. 134 -6- 65.830 feet Wire, No. 4 aluminum cable steel reinforced 14,190 feet Wire, 1/0 aluminum cable steel reinforced 6,225 feet Wire, 4/0 aluminum cable steel reinforced 20,580 feet Wire, 336.4 MCM aluminum cable steel reinforced 7,390 feet Wire, No. 6 synthetic insulated aluminum 2,895 feet Wire, No. 4 synthetic insulated aluminum 43,040 feet Wire, No. 2 synthetic insulated aluminum 31,160 feet Wire, 1/0 synthetic insulated aluminum 270 feet Wire, 4/0 synthetic insulated aluminum 1,880 feet Wire, tree, No. 2 synthetic insulated copper 6 each 140 each 691 each 38 each 988 each 43 each 391 each 31 each 12 each 41 each 42 each, 3 each 34 each 15 each 6 each 561 each 1 each 9 each 209 each 51 each 386 each 152 each 28 each 39 each 15 each 41 each 515 each 220 each 107 each Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, Insulator, pin type, Std. 135 pin type, Std. 138 pin type, Std. 139 pin type, Std. 142A pin type, Std. 142B knob type, Std 167 spool type dead -end, Std. 166 guy strain, Std. 130 Hewlett Hewlett Hewlett Hewlett Hewlett Hewlett Clamp, dead -end, automatic, #6 -1 Clamp, dead -end, automatic, 1/0 -4/0 Clamp, dead -end, flexible, #6 -1 Clamp, dead -end, flexible, 1/0 -4/0 Clamp, long strain, Std. 153 Clamp, loop type dead -end, Std. 261 Clamp, dead -end strain (for ACSR) Clamp, insulator conductor Grip, preformed (for ACSR) Clevis, dead -end, #555 Clevis, thimble dead -end, Std. 48 -7- type dead -end, type dead -end, type dead -end, type dead -end, type dead -end, type dead -end, Std. Std. Std. Std. Std. Std. 131 131 (2 132 132 (2 133 133 (2 suspension type dead -end, Std. 235 suspension type dead -end, Std. 235 suspension type dead -end, Std. 235 service bracket, Std. 186 each) each) each) (2 each) (3 each) 1 each Oil circuit breaker, Kelman type F2, 15 Kv, 400 Amp., serial #20986 1 each Switch, Kelman type Y151, 16 Kv., 200 Amp., serial #7702 15 each Switch, REC disconnect, 16 Kv 7 each Switch, pole top, KPF horizontal, 16 Kv 5 each Switch, pole top, PEM horizontal, 16 Kv 2 each Switch, pole top, Cole Electric, horizontal, 16 Kv 1 each Sensitive ground unit 19 each Banked secondary 3 each Fuseholder, Std. 187 134 each Ground assembly 32 feet Conduit, 1 -1/4" H.D.G. 30 feet Conduit, 2" fibre 2 each Condulet, 1 -1/4" 1 each Weatherhead, 1 -1/4" 1 each Pole, disconnect switch, 10 1 each Receptacle, switch pole, 11 Line Transformers 1 each Transformer, 1 each Transformer, 22 each Transformer, 2 each Transformer, 31 each Transformer, 25 each Transformer, 6 each Transformer, 9 each Transformer, 6 each Transformer, 5 each Transformer, 2 -1/2 Kva, 12000 120/240 Volt, 1 -Phase 3 Kva, 12000- 120/240 Volt, 1 -Phase 5 Kva, 12000- 120/240 Volt, 1 -Phase 5 Kva, 12000- 120/240 Volt, CP, 1 -Phase 10 Kva, 12000 120/240 Volt, 1 -Phase 10 Kva, 12000 120/240 Volt, CP, 1- Phase 10 Kva, 12000 120/240 Volt, CPB, 1 -Phase 15 Kva, 12000 120/240 Volt, 1 -Phase 15 Kva, 12000- 120/240 Volt, CP, 1 -Phase 15 Kva, 12000 120/240 Volt, CPB, 1 -Phase -8- 3 each Transformer, 9 each Transformer, 3 each Transformer, 1 each Transformer, 9 each Transformer, 1 each Transformer, 4 each Transformer, 1 each Transformer, 17 each Transformer, 12 each Transformer, 20 each Tr,:i.nsformer, 2 each Transformer, 4 each Transformer, 3 each Transformer, 3 each 3 each 1 each 1 each, 4 each 4 each 4 each 2 each 5 each 1 each 1 each Transformer, Tr nsformer, Transformer, Transformer, Transformer, Transformer, Transformer, Transformer, Transformer, Transformer, Transformer, 117 each Hanger, transformer 91 each Support, bolted transformer 278 each Fuseholder, Std. 187 25 Kva, 12000 120/240 Volt, 1 -Phase 25 Kva, 12000 120/240 Volt, CP, 1- Phase 25 Kva, 12000 120/240 Volt, CPB, 1 -Phase 37 -1/2 Kva, 12000 120/240 Volt, 1 -Phase 50 Kva, 12000 120/240 Volt, 1 -Phase 75 Kva, 12000 120/240 Volt, 1 -Phase 100 Kva, 12000- 120/240 Volt, 1 -Phase 5 Kva, 12000- 240/480 Volt, 1 -Phase 10 Kva, 12000 240/480 Volt, 1 -Phase 15 Kva, 12000 240/480 Volt, 1 -Phase 25 Kva, 12000 240/480 Volt, 1 -Phase 30 Kva, 12000- 240/480 Volt, 1 -Phase 37 -1/2 Kva, 12000 240/480 Volt, 1 -Phase 50 Kva, 12000 240/480 Volt, 1 -Phase 167 Kva, 12000 240/480 Volt, 1 -Phase 25 Kva, 12000 480/2400 Volt, 1 -Phase 15 Kva, 12000 120/240 Volt, 3 -Phase 25 Kva, 12000 120/240 Volt, 3 -Phase 15 Kva, 12000 240/480 Volt, 3 -Phase 30 Kva, 12000- 240/480 Volt, 3 -Phase 37 -1/2 Kva, 12000 240/480 Volt, 3 -Phase 45 Kva, 12000 240/480 Volt, 3 -Phase 50 Kva, 12000 240/480 Volt, 3 -Phase 100 Kva, 12000 240/480 Volt, 3 -Phase 112 -1/2 Kva, 12000 240/480 Volt, 3 -Phase 18 each Capacitor,50 CKVA, 7200 Volt, 1 -Phase 3 each Switch, capacitor 1 each Control, capacitor, automatic -9- 5 each Basket, capacitor, 4 -unit Customer's Substation City of Fullerton Municipal Water Plant 3 each Transformer, 200 Kva, 11500 460/2300 Volt, 1- Phase, G.E. serial #2833133, #2833134, #2833135 1 each Transformer, 3 Kva, 480 120/240 Volt, 1- Phase, G.E. serial #3439139 3 e:ch Switch, disconnect, 16 Kv, 400 Amp., SPST 6 each Bolt, hook Std. 152 1 each Pole, switch, 8 ft. 1 each Receptacle, switch stick, 9 ft. 11 each Insulator, station post, Std. 268 29 each Insulator, station post, Std. 271 40 each Saddle, 2" pipe 29 each Strap, bus support 11 each Support, bus, 1/4" x 2 Be 9 each Clamp, bus bar 132 feet Bar, copper, 1/4" x 2" 98 feet Tubing, copper, 1/2" IPS 15 each Connector, tee 38 feet Wire, No. 2 varnished cambric, 13.5 Kv 42 feet Wire, 500 MCM rubber covered 12 each Terminal, pressed tube 3 each Terminal, No. 4 to flat 505 feet Pipe, 2" galv. 91 each Cap, pipe 11 each Flange, floor 56 each Clamp, cross plate 6 each Clamp, cross, 90 degree 22 each Clamp, elbow 3 each Clamp, dead -end, for 2" pipe 171 feet Fencing, ch,.in link, 72" -10- 26 each B.,r tension 93 each Band, tension 46 each Band, wire fabric 1 each Gate, walk, 4 x 6" 12 each Brace, sway, 5/16" strand steel 6 feet Conduit, 3/4" H.D.G. 1 each Condulet, 3/4" 1 each Weatherhead, 3/4" 1 each Switch, safety, Square D Cat. #46341R, 30 Amp., 575 Volt 6 feet Steel, flat, 5/16" x 2" 11 feet Iron, angle, 3" x 1/4" 1 lot Station grounding 1 lot Miscellaneous material Services 15 each Service, 2 -wire, No. 8 weatherproof copper 2 each Service, 2 -wire, No. 6 weatherproof copper 34 each Service, 3 -wire, No. 8 weatherproof copper 33 each Service, 3 -wire, No. 6 weatherproof copper 6 each Service, 3 -wire, No. 4 weatherproof copper 3 each Service, 3 -wire, 2/0 weatherproof copper 1 each Service, 3 -wire, 500 MCM weatherproof copper 2 each Service, 2 -No. 8 weatherproof copper 1 -No. 6 synthetic insulated aluminum 1 each Service, 1 -No. 8 weatherproof copper 2 -No. 6 synthetic insulated aluminum 17 each Service, 2 -wire, No. 6 synthetic insulated aluminum 371 each Service, 3 -wire, No. 6 synthetic insulated aluminum 70 each Service, 3 -wire, No. 2 synthetic insulated aluminum 5 each Service, 3 -wire, 1/0 synthetic insulated aluminum 3 each Service, 3 -wire, 4/0 synthetic insulated aluminum 2 each Service, 2 -wire, No. 8 synthetic insulated copper (in conduit) 1 each Service, 3 -wire, No. 8 synthetic insulated copper (in conduit) 12 each Service, 3 -wire, No. 6 synthetic insulated copper (in conduit) 2 each Service, 3 -wire, No. 4 synthetic insulated copper (in conduit) 2 each Service, 3 -wire, No. 2 synthetic insulated copper (in conduit) 1 each Service, 3 -wire, 4/0 synthetic insulated copper (in conduit) 1 each Service, U.G., No. 6 synthetic insulated copper 1 each Service, U.G., 2 -No. 2& 1 -No. 4, 3 /c, 1 Kv, twisted synthetic insulated copper cable 3 each Service, U.G., 2 -250 MCM 1 -2/0, 3 /c, 1 Kv, twisted synthetic insulated copper cable 2 each Service, U.G., 250 MCM, 3 /c, 1 Kv, twisted synthetic insulated copper cable 1 each Service, U.G.,500 MCM, 3 /c, 1 Kv, twisted synthetic insulated copper cable 2 each Service, U.G., 1 /0, 3 /c, 1 Kv, twisted synthetic insulated aluminum cable 2 each Service, U.G., 4/0, 3 /c, 1 Kv, twisted synthetic insulated aluminum cable 2 each Service, U.G., 2 -350 MCM 1 -4/0, 3 /c, 1 Kv, twisted synthetic insulated aluminum cable 1 each Service, U.G., 2 -700 MCM 1 -350 MCM, 3 /c, 1 Kv, twisted synthetic insulated aluminum cable 1 each Service, U.G., 700 MCM, 3 /c, 1 Kv, twisted synthetic insulated aluminum cable -12- 1 each Rack, service, Std. 283 45 feet Conduit, 3/4" H.D.G. 311 feet Conduit, 1" H.D.G. 24 feet Conduit, 1 -1/4" H.D.G. 36 feet Conduit, 1 -1/2" H.D.G. 112 feet Conduit, 2" H.D.G. 12 feet Conduit, 2 -1/2" H.D.G. 114 feet Conduit, 3" H.D.G. 49 feet Conduit, 3 -1/2" H.D.G 139 feet Conduit, 4" H.D.G. 44 feet Conduit, 4" PVC 318 feet Conduit, 2" fibre 84 feet Conduit, 3" fibre 43 feet Conduit, 4" fibre 76 feet Conduit, 5" fibre 81 feet Conduit, 6" fibre 1 each Condulet, 1 -1/2" 21 each Weatherhead, 1" 2 each Weatherhead, 1 -1/4" 3 each Weatherhead, 1 -1/2" 1 each We therhead, 2 -1/2" 21 each Elbow, 1" H.D.G. 2 each Elbow, 1 -1/4" H.D.G. 4 each Bend, 3" fibre 38 each Block, U.G. riser 10 each Grip, Kellem 6 each Support, service drop grip 3 each Insulator, knob type, Std. 167 -13- Meters 16 each Meter, 5 Amp., 120 Volt, 1 -Phase 27 each Meter, 15 Amp., 120 Volt, 1 -Phase 4 each Meter, 2.5 Amp., 240 Volt, 1 -Phase 17 each Meter, 5 Amp., 240 Volt, 1 -Phase 1 each Meter, 10 Amp., 240 Volt, 1 -Phase 467 each Meter, 15 Amp., 240 Volt, 1 -Phase 4 each Meter, 25 Amp., 240 Volt, 1 -Phase 1 each Meter, 30 Amp., 240 Volt, 1 -Phase 5 each Meter, 50 Amp., 240 Volt, 1 -Phase 6 each Meter, 2.5 Amp., 240 Volt, 1 -Phase 2 each Meter, 30 Amp., 240 Volt, 1- Phase, 2 each Meter, 2.5 Amp., 240 Volt, 3 -Phase 14 each Meter, 15 Amp., 240 Volt, 3 -Phase 1 each Meter, 30 Amp., 240 Volt, 3 -Phase 3 each Meter, 50 Amp., 240 Volt, 3 -Phase 6 each Meter, 15 Amp., 480 Volt, 3 -Phase 1 each Meter, 30 Amp., 480 Volt, 3 -Phase 23 each Meter, 50 Amp., 480 Volt, 3 -Phase 9 each Meter, 2.5 Amp., 240 Volt, 3- Phase, 1 each Meter, 50 Amp., 240 Volt, 3- Phase, 4 each Meter, 2.5 Amp., 480 Volt, 3- Phase, 1 each Meter, 2.5 Amp., 480 Volt, 3- Phase, 30 each Adapter, meter, Std. 320 2 each Box, meter, Std. 252 15 each Box, meter, Std. 310 w /ch..nnel 5 each Box, meter, Std. 322 -14- 139 each Block, test, 2 -pole, Std. 342 1 each Block, safety, 4 -pole, Std. 302 27 each Block, safety, 6 -pole, Std. 304 indicating demand indicating demand indicating demand indicating demand indicating demand reactive 9 each Switch, test, Std. 325 2 each Switch, test, Std. 346 9 each Switch, test, Std. 347 4 each Switch, test, Std. 348 17 each Cover, test switch, Std. 329 2 each Transformer, current, 100 /5 Amp., 600 Volt, indoor type 4 each Transformer, current, 200/5 Amp., 600 Volt, indoor type 10 each Transformer, current, 400/5 Amp., 600 Volt, indoor type 2 each Transformer, current, 600/5 Amp., 600 Volt, indoor type 10 each Transformer, current, 200 -200/5 Amp., 600 Volt, indoor type 1 each Transformer, current, 200 -200/5 Amp., 1200 Volt, indoor type 5 each Transformer, current, 400 -400/5 Amp., 1200 Volt, indoor type 4 each Transformer, current, 100 /5 Amp., 5000 Volt, indoor type 4 each Transformer, current, 200/5 Amp., 5000 Volt, indoor type 1 each Transformer, phasing, 480 Volt, 2- element, 3 -wire Street Lighting and Signal Systems 2 each Transformer, type R.O., 10 Kva, 6.6 Amp., 1 -Phase 1 each Light, center suspension, Std. 356 3 each Controller, photo electric 1 each Transformer, type IL -15- 2 each Support, bolted transformer 1 each Box, meter, Std. 310 w /channel 1 each Pin, wood, insulator, Std. 162 1 each Insulator, pin type, Std. 134 20 feet Conduit, 3/4" H.D.G. 58 feet Conduit, 1 -1/4" H.D.G. 73 feet Conduit, 2" fibre 1 each Condulet, 2" 1 each Bend, 2" fibre ITEM 2 Communication Equipment 35 each Crossarm, wood, single, Std. 80 42 each Crossarm, wood, single, Std. 81 3 each Crossarm, wood, double, Std. 81 6 each Crossarm, wood, double, Std. 82 17 each Crossarm, wood, single, Std. 83 1 each Bracket, 3 -wire, Std. 158 11 each Bracket, transposition, Std. 244 205 each Pin, wood, insulator, Std. 162 16 each Pin, steel, insulator, Std. 163 42,100 feet Wire, No. 8 bare copper 230 each Insulator, pin type, Std. 134 2 each Insulator, pin type, Std. 135 4 each Insulator, spool type dead -end, Std. 166 16 each Insulator, suspension type dead -end, Std. 235 12 each Clevis, thimble dead -end, Std. 48 -16- J 0 z 0 z w z O 2 0 0 cc 1- w W J Z Z J 9 Q cc cr O Q c�oz Z Z O O LA w O 0 0 1S n 2 0 w w J J z w O a 2 J a Lu a z z L7 O ES O U w w 0 S w O cc w Z J J O Q Q C J F- Cr CC w a Q 0 O •O a z VT 0 W 0 w 1 w J J O a a J z a p O Z`_� v O 0 O J c'? J o r H 3 w v; 0 m w CC C( w w w 0 Z Z Z z J J Z Q Q C O L J F H U J J I l W 0 Q Q m 0 a L� d d Z m 0 IJ C.!) a J Q 1 21 W o w L w _J_ O C, Z w w a 0 J Z C- ZZ 01 r v, w 0 m Q z CD w o wo G z J C H W Q w 0 v) a w w F- w w I- w 0 w Z Z D z F w Q Z J I J J CC CC (f) L,_ 2 0_ 5 w w W 0 a a w J 0 Z 0 W CC 0 w H- O m F- 0 J Q U a m TI. 17.4 o -J w z 7 1S 131111HM .LS/HA/0$ 0 lg 77I_LAI 59Y"..7. fr.LS/4 CV& PC bJ IMMIIIMI.MIMMI jo W i n 0 %MH d7.7 a l l W (t5 W7ba w ss Helalvd Z I r N M z 6 2 W z tS Z iaa °3 1S llbd 1- W 0 2 W YS 0 MP 1 s 4 0 y a 0 1 J� Pip YaV 77 2 1 m z g„ ,e 41- 9; t. \7 -w L h w 2 z J 1 W 0 1 0 0 b71N 2. W tip y 0 S 0 V m 7 0 UE T U r fr a. 111 0 z '3AV •1S 4. /o bNOWOd NOW37 w z 1S ONO WAYb NbYd 'j dbOH13FJNVWo rE e 2) rz b b 7YYI Ot- Na I 04 mg h R R, Q 8 M i 07I 21 11157V. 2� 4S J. 7 OHO '3AV uj oC 0 w ,Y 32iclAD 1 a r k ti N np —.nem g G■t v401' cl m w 2 9 1S s� ..a64,> EA 5T LINE RGi SAN JUAN CAJON Qe SANTA ANA 1 ti& 496 SN N32/n8 N /A Nc S 3j _43(' '4) .41N 4 44. 6 0 4P 41 0. r 1 41sic 0 40 J Od 2 4) b o 1• o Kb s x n z W a @S Z M V 0 pz 8 e 2 ic Er 11, ri 9 0 0 W W 2 h W n TI '2AV V /.LN37V7d IF v, TI Vi 1S LJJ 2 z 13 tS bfl- OOtie G W z 15 S 'b lb/10)S9N /31 NOJJN! c■J LJ z 1 x h w 7 ig 4 1 'CarNo, OOO v =13v b t. S m p mV O (4S ind) bb W W Ppp N N Q �P 1S 4, a .1 JN/,O.] d�S 1S m� I e l a It 75.°4 11 41: 3 d el r 1, t Ie II t leh" b e l e_ e__ e s4 v 77i 4 e OY YaSoLV YIJ 41 z E8 3 N lek teuN301■70 ori /61 s V n 0 1. Id Id x .91V.Sfr 15' op z g it .LS Isann coa a 1 1 11 --111 00 1,1 0 2 LJ 3AW CD g. 1' 12V 0 g3 et 81,, a •K R V2S vo7 0 0 ar vsYr iu 0 0., 0 z r..4a•ggoe v o.-ar A•lo 7 1 a A/7 22/007 PR Iu Lu M 0 g $ly new AL_ et, 10 ƒ 2 J o e ov ��o z fl 3 e e 71 "Lb f ƒ ƒ e a) -LS 4 511 S 0 O__ 4 V. e e �e� i Q -LP* e e e ri 0 Id 6- w W m moo L. a w Z ei sj le ie 0 u 0 IL) 71 0 s 5 0 -r 'ekt A `0,.; 3n7 7 A,09 az 1.91 Y- 0, 1— T1-57W e 77,7 G qs,.lei je r1 Ipe d o 2, WO, PItt r VO 7 21 Mar t<*dc Qvt D pp r! OHN F a oU 8b e e e fr R/ V VO7 T is V7 1S /a n//7S LC) L w z e :13 b.18 /4 0/b in 0 fir �rM2 t/ NO. LC) CD c_o LO Iu a. 0 L P ALI4 3‘3 The Council hereby finds that the taking of the property described above is necess ry for the said public utility extension and public improvement. SECTION 3. Said public improvement is planned and located in the manner which will be most comp.tible with the greatest public good and the least private injury. SECTION 4. The City Attorney of the City of Anaheim is hereby directed to bring an action in the Superior Court of the State of California, in and for the County of Orange, in the name of the City of Anaheim to condemn by eminent domain proceedings the property described in Section 2 hereof. SECTION 5. For the purposes of bringing such an action, the City Attorney is hereby empowered to incur in the name of and on behalf of said City, all obligations and expenses incidental thereto. AT4ST ITEM 3 All rights of way, easements, interests, licenses, franchises, and rights pertaining to any p..rt of the distribution system of said Southern California Edison Company now held, owned, or used by said Southern California Edison Company for the erec- tion, construction, maintenance, or operation of that portion of the distribution and communication systems to be taken by the City and described above in Items 1 and 2. ITEM 4 All commercial and engineering maps and records of said Southern California Edison Company used or useful in locating, identifying and operating the above described properties or any part thereof, sought to be condemned, meter records, trans- former records, billing records, service records, consumers' service contracts, and all other records necessary or conven- ient in recording, billing or collecting for electric service in said certain portions of the City of Anaheim and for main- taining s,: id distribution system nd each and every part thereof, sought to be condemned. r CI CLERK OF THE CITY OF ANAHEIM -17- THE FOREGOING RESOLUTION is approved and signed by me this 8th day of October 1963. STATE OF CALIFORNIA) COUNTY OF ORANGE ss. CITY OF ANAHEIM I, DENE M. WILLIAMS, City Clerk of the City of Anaheim, do hereby certify that the foregoing Resolution No. 63R -808 was introduced and adopted at a regular meeting provided by law, of the City Council of the City of Anaheim, held on the 8th day of October, 1963, by the following vote of the members thereof: AYES: COUNCILMEN: Dutton, Chandler, Krein and Coons NOES: COUNCILMEN: None ABSENT: COUNCILMAN: Schutte AND I FURTHER CERTIFY that the Mayor of the City of Anaheim approved and signed said Resolution No. 63R -808 on the 8th day of October, 1963, IN WITNESS WHEREOF, I have hereunto set my hand and affixed the official seal of the City of Anaheim, this 8th day of October, 1963. (S EA L )7( CITY CLERK OF THE CITY OF ANAHEIM