Permit Number: BLD2023-06169
Issued: 10/09/2024
CITY OF ANAHEIM
www.anaheim.net/buliding
(714)765-4626
Quarter Section: 114
Site Address: 822 S PRISCILLA ST C, ANAHEIM, CA 92806
Legal Description: P BK 330 PG 7 PAR 3
APN:25304237
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(7141766 - 5153
Project Description: (JADU) Residential Addition: 465 sq ft to convert portion of existing attached garage into new attached junior
accessory dwelling unit. Install 400amp 3 gang meter. (1BD/1BA)
Living Area: 465 Number of Stories: 1 Valuation:
Garage Area: Construction Types:
Carport Area: Occupancy Groups:
Balcony / Deck Area: Fire Sprinklered:
Cool Roof: Total Fees paid for Permit:
48,000.00
VB
No
2,817.26
People Associated with Project:
Contractor K V BUILDERS
12742 FIREBRAND CIRCLE GARDEN GROVE, CA 92840
Owner DO, THUY DINH TR
T D DO 8
822 S PRISCILLA ST
Engineer- Civil Michael M Phillips
17342 Roseleaf ave Tustin, CA 92780
Type Electrical Fixtures
Oty
Type
Plumbing Fixtures Qty Mechanical Fixtures
Qty
Meter/Disc Sw - Under 600 V, up to 200
3
Bath Tub
1 Mini Split (Exterior condenser)
1
amps
Garbage Disposal
1 Mini Split (room unit)
2
Receptacle, switches, lights
30
Ventilation Fan - <= 300 cfrn on single duct
3
Sub PaneVTemp Pwr - Under 600 V, up to
1
Kitchen Sink
1
200 amps
Lavatory
1
Repair/Drainage AlteratlonlVent Piping
Washing Machine Rough
Water Closet
Water Distnbution
Water Heater
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the
date of permit issuance. A new permit is required to commence or continue work.
City of Anaheim
Building Division
Do not occupy this building until the final inspections have been made.
INSPECTION DATE INSPECTOR
Do not pour concrete until the following applicable items have been signed:
'umbing (Ground/Underfloor Drain Waste)
ectrical Ground Electrode/Ufer
stback/Forms/Trenches (Footings) t
o not install subfloor or pour floor slab until the follwinJg appli able lerns have beer
sioned
umbing (Ground/Underfloor Water)
nderfloor Rough Gas
Reinf
Insulation (Raised Foundation
Ig (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
been sianed
list Floor Shear 121WIJ-1 J,$C-
Floor Shear
Duct (Mach
Mechanical
Electrical
Rough COA/Mitagation Measures
Framing (Only after Plbg., Ele., Mec. & Fire)
Insulation(Sound/Energy) ��ay J, JiG
Do not tape or plaster until the following applicable items have been signed:
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Service Meter -(Meter will be set w
business days after approval) Excludes New
Construction
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele., or Mec.)
J37C
FINAL INSPECTIONS
I DATE
I INSPECTOR
All applicable items below must be signed before u ilities are released
Final Gas Test
JIYC
Electrical Final
is
WC
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765.5126
Fire Sprinkler (ONLY) (714) 765-5041
Fire Dept. Final (714) 7655041
Water Engineering (714) 765-4591
Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days)
CaA/Migation Measures
Building Final (714 765-5153)
'ast Inspection -Final Only After Above Completed
PARTIAL INSPECTIONS
Building Inspections
Mechanical Inspections
Plumbing Inspections
Electrical Inspections
Backflow (Testable
Service