Loading...
1962-0327ANAHEIM: RESOLUTION NO. 62R 327 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ANAHEIM FINDING AND DETERMINING THAT THE PUBLIC INTEREST AND NECESSITY REQUIRE THE ACQUISITION, CONSTRUCTION AND COMPLETION OF A PUBLIC UTILITY EXTENSION AND PUBLIC IMPROVEMENT, CON- SISTING OF ELECTRIC LIGHT, HEAT AND POWER LINES AND WORKS IN CERTAIN PORTIONS OF THE CITY OF ANAHEIM AND THE ACQUISITION THEREOF BY THE CITY OF ANAHEIM BY EMINENT DOMAIN PROCEEDINGS OF CERTAIN PROPERTY OF SOUTHERN CALIFORNIA EDISON COMPANY IN SAID CERTAIN PORTIONS OF SAID CITY. BE IT RESOLVED BY THE COUNCIL OF THE CITY OF Attorney R/W Finance Dir Oelkers, Geo SECTION 1. It is hereby found and determined that the public interest and necessity require the acquisi- tion, construction and completion of a public utility extension and public improvement, consisting of electric light, heat and power lines and works in the City of Anaheim as hereinafter more particularly described in the appendix attached hereto and by this reference made a part hereof, to be used for and necessary for: (1) the transmission and distribution of electricity for the purpose of furnishing and supplying electric light, heat and power to the City of Anaheim and certain of the inhabitants thereof; and (2) the proper development and control of such use of such electricity, at this time, and the future proper development and control thereof, as a part of the electrical system owned and operated by the City of Anaheim for furnishing and supplying electrical energy to said City and certain of the inhabitants thereof. SECTION 2. The public interest and necessity require the taking and acquisition by the City of Anaheim for said public utility extension and public improvement and use, of the electric light, heat and power distribution system of the Southern California Edison Company located within said certain portions of the City of Anaheim, including: ITEM 1 Poles and Fixtures: 1 each Pole, wood, BT, 50 ft. (.65 interest) 2 each Pole, wood, TFL, 30 ft. (.50 interest) 6 each Pole, wood, TFL, 35 ft. (.50 interest) 4 each Pole, wood, TFL, 40 ft. (.50 interest) 143 each Pole, wood, TFL, 40 ft. (.60 interest) 5 each Pole, wood, TFL, 40 ft. (.67 interest) 2 each Pole, wood, TFL, 45 ft. (.27 interest) 2 each Pole, wood, TFL, 45 ft. (.33 interest) 1 each Pole, wood, TFL, 45 ft. (.50 interest) 94 each Pole, wood, TFL, 45 ft. (.60 interest) 5 each Pole, wood, TFL, 45 ft. (.65 interest) 45 each Pole, wood, TFL, 45 ft. (.67 interest) 1 each Pole, wood, TFL, 45 ft. (.83 interest) 7 each Pole, wood, TFL, 50 ft. (.32 interest) 1 each Pole, wood, TFL, 50 ft. (.33 interest) 3 each Pole, wood, TFL, 50 ft. (.60 interest) 25 each Pole, wood, TFL, 50 ft. (.65 interest) 1 each Pole, wood, TFL, 50 ft. (.67 interest) 1 each Pole, wood, TFL, 55 ft. (.33 interest) 2 each Pole, wood, TFL, 55 ft. (.35 interest) 7 each Pole, wood, TFL, 55 ft. (.50 interest) 9 each Pole, wood, TFL, 55 ft. (.70 interest) 6 each Pole, wood, TFL, 60 ft. (.23 interest) 1 each Pole, wood, TFL, 60 ft. (.38 interest) 1 each Pole, wood, TFL, 60 ft. (.70 interest) 2 each Pole, wood, TFL, 75 ft. (.25 interest) 2 each Pole, wood, TFL, 85 ft. (.25 interest) 5 each Pole, wood, TFL, 85 ft. (.33 interest) 1 each Pole, wood, PT, 40 ft. 1 each Pole, wood, PT, 55 ft. -2- 5 each Pole, wood, TFL, 25 ft. 6 each Pole, wood, TFL, 30 ft. 11 each Pole, wood, TFL, 35 ft. 28 each Pole, wood, TFL, 40 ft. 26 each Pole, wood, 1rL, 45 ft. 7 each Pole, wood, TFL, 50 ft. 5 each Pole, wood, TFL, 55 ft. 2 each Pole, wood, TFL, 60 ft. 1 each Pole, wood, TFL, 65 ft. 18 each Crossarm, wood, single, Std. 80 11 each Crossarm, wood, double, Std. 80 200 each Crossarm, wood, single, Std. 82 65 each Crossarm, wood, single, Std. 82 2 each Crossarm, wood, triple, Std. 82 71 each Crossarm, wood, single, Std. 83 12 each Crossarm, wood, double, Std. 83 215 each Crossarm, wood, single, Std. 86 21 each Crossarm, wood, double, Std. 86 2 each Crossarm, wood, triple, Std. 86 39 each Crossarm, wood, single, Std. 100 2 each Crossarm, wood, single, 12 ft. 2 each Timber, 4" x 6" x 12' 1 each Timber, 4" x 6" x 16' 43 each Guy, 1/4" aerial 3 each Guy, 5/16" aerial 214 each Guy, 5/16" down 6 each Guy, 7/16" down 3 each Guy, 5/16" sidewalk -3- 5 each Anchor, 15" plate and Std. 127 rod (1/2 interest) 1 each Anchor, 20" plate and Std. 127 rod (1/2 interest) 5 each Anchor, 20" plate and Std. 128 rod (1/2 interest) 80 each Anchor, 20" plate and Std. 177 rod (1/2 interest) 27 each Anchor, 15" plate and Std. 126 rod 15 each Anchor, 15" plate and Std. 127 rod 7 each Anchor, 20" plate and Std. 127 rod 1 each Anchor, 20" plate and Std. 128 rod 11 each Anchor, 20" plate and Std. 177 rod 144 each Cover, wood, guy wire, Std. 46 5 each Cover, metal, giiy wire 10 each Brace, vertical, Std. 71 1 each Brace, alley arm, Std. 72 1 each Brace, wood, heel and toe 2 each Extension, pole top, Std. 73 8 each Bracket, 3 wire, Std. 158 4 each Bracket, wye -bus, Std. 295 12 each Rack, service, Std. 283 381 each Rack, secondary, Std. 284 22 each Rack, service take -off, Std. 366 3 each Platform, transformer 8'6" 1 each Platform, transformer 13'6" 134 each Conduit, 2" fibre 282 each Pin, wood, insulator, Std. 162 208 each Pin, steel, insulator, Std. 163 875 each Pin, steel, insulator, Std. 164 21 each Pin, steel, insulator, Std. 247 11 each Pin, steel, insulator, Std. 267 426 each Step, pole, Std. 34 315 each Strip, visibility, Std. 249 Overhead Conductors 27,128 13,165 20,160 20,745 1,900 5,555 2,970 915 65,005 2,295 3,570 750 12,875 75,462 116 274 115 111 76 828 6 feet feet feet feet feet feet feet feet feet feet feet feet feet feet feet Wire, Wire, Wire, Wire, Wire, Wire, Wire, Wire, and Devices: No. 6 bare copper No. 4 bare copper No. 1 bare copper 2/0 bare copper No. 8 No. 6 No. 4 No. 2 each insulator, each insulator, each insulator, each insulator, each insulator, each insulator, 3 each insulator, 15 each insulator, 130 each insulator, 5. each insulator, 13 each insulator, 42 each insulator, weatherproof weatherproof weatherproof weatherproof copper copper copper copper Wire, No. 4 aluminum cable steel reinforced Wire, 4/0 aluminum cable steel reinforced Wire, 336.4 MCM aluminum cable steel reinforced Wire, No. 6 synthetic insulated aluminum Wire, No. 2 synthetic insulated aluminum Wire, 1/0 synthetic insulated aluminum Wire, No. 6 varnish cambric pin type, Std. 134 pin type, Std. 138 pin type, Std. 139 pin type, Std. 142A pin type, Std. 142B pin type, Std. 142C pin type, Std. 145 knob type, Std. 167 spool type dead -end, Std. 166 strain type, Std. 130 Hewlett type dead -end, Std. 131 Hewlett type dead -end, Std. 131 (2 each) 34 each insulator, Hewlett type dead -end, Std. 132 11 each insulator, Hewlett type dead -end, Std. 132 (2 each) 319 each insulator, suspension type dead ends Std. 235 (2 each) 3 each insulator, suspension type dead -end, Std. 235 (3 each) 132 each Clamp, dead -end, automatic, No 6 -1 45 each Clamp, dead -end, flexible, No. 6 -1 275 each Clamp, dead -end, flexible, 1/0 416 each Grip, preformed (for ACSR) 10 each Clamp, strain type, Std. 153 15 each Clamp, insulator conductor (18 -4135) 238 each Clevis, dead end #555 11 each Clevis, thimble dead -end, Std. 48 48 each Banked secondary 18 each Switch, REC disconnect, 12 kv 2 each Switch, pole top, KPF horizontal, 16 kv,' gang operated 1 each Switch, pole top, PEM horizontal, 16 kv, gang operated 1 each Switch, pole top, Cole Electric, horizontal, 16 kv 94 each Ground assembly Line Transformers: 3 each Transformer, 2 -1/2 kva, 12000- 120/240 volt, 1 phase 7 each Transformer, 5 kva, 12000- 120/240 volt, 1 phase 1 each Transformer, 5 kva, 12000- 120/240 volt, CP, 1 phase 24 each Transformer, 10 kva, 12000 120/240 volt, 1 phase 22 each Transformer, 10 kva, 12000 120/240 volt, CP, 1 phase 8 each Transformer, 10 kva, 12000 120/240 volt, CPB,1 phase 3 each Transformer, 15 kva, 12000- 120/240 volt, 1 phase 18 each Transformer, 15 kva, 12000 120/240 volt, CP, 1 phase -6- 3 each 6 each 3 each 2 each 1 each 1 each 1 each 2 each 1 each 2 each 3 each 31 each 77 each 112 each Services: 5 each 1 each 21 each 27 each 1 each 2 each 418 each 19 each 1 each 4 each Transformer, Transformer, Transformer, Transformer, Transformer, Transformer, Transformer, Transformer, 37 -1/2 kva, 12000- 240/480 volt, 3 phase Transformer, 45 kva, 12000- 240/480 volt, 3 phase Transformer, 50' kva, 12000- 240/480 volt, 3 phase Transformer, 75 kva, 12000 240/480 volt, 3 phase Hanger, transformer Support, bolted, transformer Fuseholder, Std. 187 Service, 2 -wire, Service, 2 -wire, Service, 3 -wire, Service, 3 -wire, Service, 3-wire, Service, 3 -wire, Service, 3 -wire, Service, 3 -wire, Service, 3 -wire, Service, 3 -wire, 15 kva, 12000 120/240 volt, 25 kva, 12000 120/240 volt, 25 kva, 12000 240/480 volt, 50 kva, 12000. 240/480 volt, 25 kva, 12000- 120/240 volt, 10 kva, 12000- 240/480 volt, 30 kva, 12000- 240/480 volt, aluminum (in conduit) 1 each Service, U.G., No. 4 rubber covered copper 1 each Service, U.G., 2 -1 /0 and 1 -No. 2, 3 /C, 1 kv synthetic insulated aluminum cable -7- No. 8 weatherproof copper No. 6 weatherproof copper No. 8 weatherproof copper No. 6 weatherproof copper No. 4 weatherproof copper No. 2 weatherproof copper No. 6 synthetic insulated aluminum No. 2 synthetic insulated aluminum 1/0 synthetic insulated aluminum No. 4 synthetic insulated CPB ,1 phase CP, 1 phase 1 phase 1 phase 3 phase 3 phase 3 phase 1 each Rack, service, Std. 283 2 each Rack, secondary, Std. 284 39 feet 20 feet 29 feet 10 feet 19 feet 39 feet 16 feet 26 feet 2 feet 3 feet 1 feet 1 feet 1 feet 4 feet 3 each 3 each 30 each 4 each Meters: 2 each 5 each 4 each 464 each 1 each 10 each 1 each 3 each Conduit, Conduit, Conduit, Conduit, Conduit, Conduit, Conduit, Conduit, 1" H.D.G. 1 -1/2" H.D.G. 1 -3/4" H.D.G. 2 2" 2" H.D.G. P.V.C. fibre 2 -1/2" fibre 4" Square wood Condulet, 1" Condulet, 1 -1/2" Condulet, 1 -3/4" Elbow, 1" H.D.G. Elbow, 1 -1/2" H.D.G. Block, U.G. riser Pin, steel, insulator, Std. 163 Insulator, pin type, Std. 134 Insulator, knob type, Std. 167 Insulator, spool type dead -end, Std. 166 Meter, 5 amp, 120 volt, 1 phase Meter, 15 amp, 120 volt, 1 phase Meter, 5 amp, 240 volt, 1 phase Meter, 15 amp, 240 volt, 1 phase Meter, 25 amp, 240 volt, 1 phase Meter, 50 amp, 240 volt, 1 phase Meter, 50 amp, 240 volt, 3 phase Meter, 2.5 amp, 480 volt, 3 phase -8- 9 each Meter, 50 amp, 480 volt, 3 phase 6 each Adapter, meter, Std. 320 3 each Box, meter, Std. 254 4 each Box, meter, Std. 310 w /Channel 4 each Block, safety, 4 -pole, Std. 302 5 each Block, safety, 6 -pole, Std. 304 2 each Switch, test, Std. 325 1 each Switch, test, Std. 346 3 each Cover, test switch, Std. 329 2 each Transformer, current, 200/5 amp, 600 volt, EMR type 2 each Transformer, current, 100 /5 amp, 600 volt, indoor type 2 each Transformer, current, 100 /5 amp, 5000 volt, indoor type Street Lighting and Signal Systems: 1 each Transformer, R. 0. 10 kva, 6.6 amps 1 each Transformer, R. 0. 15 kva 6.6 amps 2 each Controller, photo electric 2 each Support, bolted transformer ITEM 2 All rights of way, easements, interests, licenses, fran- chises, and rights pertaining any part of the distribution sys- tem of said Southern California Edison Company now held, owned, or used by said Southern California Edison Company for the erection, construction, maintenance, or operation of that portion of the dis- tribution system to be taken by the City and described above in Item 1. -9- ITEM 3 All commercial and engineering maps and records of said Southern California Edison Company used or useful in locating, identifying and operating the above described prop- erties or any part thereof, sought to be condemned, meter records, transformer records, billing records, service records, consumers' service contracts, and all other records necessary or convenient in recording, billing or collecting for electric service in said certain portions of the City of Anaheim and for maintaining said distribution system and each and every part thereof, sought to be condemned. The Council hereby finds that the taking of the property described above is necessary for the said public utility extension and public improvement. SECTION 3. Said public improvement is planned and located in the manner which will be most compatible with the greatest public good and the least private injury. SECTION 4. The City Attorney of the City of Anaheim is hereby directed to bring an action in the Superior Court of the State of California, in and for the County of Orange, in the name of the City of Anaheim to condemn by eminent domain proceedings the property described in Section 2 hereof. SECTION 5. For the purposes of bringing such an action, the City Attorney is hereby empowered to incur in the name of and on behalf of said City, all obligations and expenses incidental thereto. THE FOREGOING RESOLUTION is approved and signed by me this 3rd day of April, 1962. ATTEST. CIS CLERK OF THE CITY OF ANAHEIM -10- Y 0 HE OF ANAHEIM STATE OF CALIFORNIA COUNTY OF ORANGE ss. CITY OF ANAHEIM I, DENE M. WILLIAMS, City Clerk of the City of Anaheim, do hereby certify that the foregoing resolution was passed and adopted at a regular meeting of the City Council held on the 3rd day of April, 1962, by the follow- ing vote of the members thereof: (SEAL) AYES: COUNCILMEN: Chandler, Coons, Fry and Schutte. NOES: COUNCILMEN: None. ABSENT: COUNCILMEN: Thompson AND I FURTHER CERTIFY that the Mayor of the City of Anaheim approved and signed said resolution on the 3rd day of April, 1962. IN WITNESS WHEREOF, I have hereunto set my hand and affixed the seal of the City of Anaheim this 3rd day of April, 1962. E CITY OF ANAHEIM