Loading...
1955-2733WHEREAS, the City Council of the City of Anaheim did cause to be published in a. newspe )er of general circulation, printed, published and circulated in the City of Anaheim, to wit: the Anaheim Bulletin, on the 15th day and the 21st day of April, 1955, a notice inviting sealed proposals for the furnishing to the City of Anaheim, in approximete quantities, of the following reinforced concrete cylinder -Ape and fittings, including rubber gaskets for installation: Item 1. 6,000 feet Item 2. One Item 3. One Item 4 One Item 5. Four 18" flanged connections to 18" gate valves. Item 6. RESOLUTION NO. 2733 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ANAHEIM ACCEPTING SEALED PROPOSAL AND AWARDING CONTRACT 1`0 THE LOWEST RESPONSIBLE BIDDER FOR THE FURNISHING TO THE CITY OF ANAHEII OF REINFORCED CONCRETE STEEL CYLINDER PIPE AND FITTINGS. UNIT A. 18" I.D. reinforced concrete steel cylinder pipe, including rubber gaskets for installation. 18" x 18" x 10" x 6" fabricated cross with 1 18" and 10" and 6" outlets adapted for flanged connection. 18" x 12" x 18" x 10" fabricated cross with 18" outlet opposite 10" outlet and 12" and 10" outlets adapted for flanged connection. 24" x 12" x 18" x 18" fabricated cross with all outlets adapted for flanged connection. Thirteen 6" flanged outlets. Item 7. Three 8" flanged outlets. Item 8. Seventy five 1" I.P.S. hub outlets, t, -1- Item 1. 11,800 feet Item 2. One Item 3. One Item 4. One Item 5. One 16" x 12" x 16" fabricated tee with 16" branch outlet and 12" outlet adapted for flanged connection. Item 6. Three UNIT B. 16" I.D. reinforced concrete steel cylinder pipe, including rubber gaskets for installation. 16" x 16" x 6" x 6" fabricated cross with both 6" outlets adapted. for flanged connections. 16" x 16" x 6" x 6" angle cross with both 6" outlets adapted for flanged connection. 16" x 6" x 16" x 12" fabricated cross with 16" outlet opposite 6" outlet and 6" and 12" outlets adapted for flanged connection. 16" x 16" x 12" x 12" fabricated cross with both 12" outlets and 1 16" outlet adapted for flanged connections. Item 2. Six 16" flanged connections to 16" gate valves. Item 8. Thirty-three 6" flanged outlets. Item 9. One 8" flanged outlet. Item 10. One Hundred 1" I.P.S. hub outlets, tapped. Seventy-five Item 11. Two 16", 26 degree elbows. AND WHEREAS, said notice did provide that said pipe and fittings shall be in accordance with, conform to and comply with "Interim Federal Specification." Pipe: Pressure, reinforced, concrete, pretensioned reinforcement (steel cylinder type) No. SS -P -00381 (GSA -FSS) issued April 2, 1953 and modified by the following: Pipe shall be Class 150 for 150 pounds maximum water working pressure. The reinforced concrete pipe may be furnished in either of two types: Pretensioned or Non- Preten- sioned. When non pretensioned pipe is furnished under this modification of the specification, it shall be the type known as steel cylinder, cement lined and coated, with the features indicated below: The design for internal pressure shall be based entirely on the steel cylinder and shall not be dependent upon any added reinforcement intended to extend the design strength of the cylinder. Cylinder shall have a wall thickness of not less than 10 gauge. Such pipe shall have the bell and spigot formed integrally with the steel cylinder. The bell shell be approximately four inches deep and have a flared lip to facili- tate assembly. Bell thickness shall be no less than 3/16" and shall be reinforced as necessary. The spigot shall have a specially rolled groove with double "shoulders" such that after field joining, the gasket will be completely enclosed on all sides and shall not depend on internal water pressure to aid the gasket in making a water -tiht joint. The pipe shall have a 1/2" cement mortar lining and a 1" cement mortar coating. The coating shall be reinforced with a 15 -1/2 Ga. wire helically wound without tension and on a 1" pitch and placed at the approx- imate center of the coating. Other details for non pretensioned pipe shall conform to desirable end applicable portions of the specifications referring to pretensioned pipe; in particular, but not limited to: steel for cylinders, cement, rubber gaskets, allowable steel fibre stress, test pressures and fitting design; and WHEREAS, such notice inviting sealed proposals for said reinforced concrete steel cylinder pipe and fittings, including rubber gaskets for installation, did provide that said sealed proposals would be received by the City Council of the City of Anaheim at the Office of the City Clerk of said City up to the hour of 7 :00 o'clock P.M. on 'Tuesday, the 26th day of .April, 1955 for the furnishing to the City of Anaheim of said pipe, fittings and gaskets; and WHEREAS, the City Clerk of the City of Anaheim did_ re- ceive sealed proposals prior to 7:00 o'clock P.1 Tuesday, the 26th day of April, 1955, for the furnishing of said reinforced concrete steel cylinder pipe and fittings, including rubber gaskets for installation, from the following persons, firms or corporations: -3-- AMERICAN PIPE AND CONSTRUCTION CO. UNIT PRICE ITEM Per Ft. or NO. TJANTITY Each UNIT A. 1 6,000' 5.14 30,240.00 2 1 215.00 215.00 3 1 354.00 354.00 4 1 429.00 429.00 5 4 86.00 344.00 6 13 47.00 611.00 7 3 56.00 168.00 8 75 3.15 236.25 UNIT B. 1 11,800 4.32 2 1 179.00 3 1 179.00 4 1 285.00 5 1 202.00 6 3 296.00 7 6 78.00 8 33 47.00 9 1 56.00 10 175 3.15 11 2 211.00 TOTAL UNITS A and B 4 88,954.50 SOUTHERN PIPE and. CASING CO. UNIT A. 1 6,000' 5.23 2 1 199.49 3 1 276.93 4 1 521.49 5 4 149.00 6 13 48.00 7 3 64.00 8 75 3.20 UNIT B. 1 11,800' 4.57 2 1 151.00 3 1 171.00 4 1 245.00 5 1 335.00 6 3 305.00 7 6 132.00 -4_ TOTAL PRICE 4 33,197.25 50,976.00 179.00 179.00 285.00 202,00 888.00 468.00 1,551.00 56.00 551.25 422.00 55,757.25 31,380.00 199.49 276.93 521.49 596.00 624.00 192.00 240.00 4 34,029.91 53,926.00 151.00 171.00 245.00 335.00 915.00 792.00 NO. WANTITY 8 33 48.00 9 1 64.00 10 175 3.20 11 2 39.21 UNITED CONCRETE PIPE CORP. UNIT A. 1 6,000' 5.20 S 31,200.00 2 1 380.00 380.00 3 1 540.00 540.00 4 1 720.00 720.00 5 4 110.00 440.00 6 13 57.00 741.00 7 3 78.00 234.00 8 75 15.00 1,125.00 UNIT B. 1 2 3 4 5 6 7 8 9 10 11 11,800' 1 1 1 1 3 6 33 TOTAL UNITS A and. B S 92, 51.33 1 175 2 -5- UNIT PRICE Per Ft. or Each 4.43 250.00 290.00 455.00 435.00 490.00 95.00 56.00 78.00 15.00 180.00 TOTAL PRICE 1,584.00 64.00 560.00 178.42 58,921.42 35, 52,274.00 250,00 290.00 455.00 435.00 1,470.00 570.00 1,848.00 78.00 2,625.00 360.00 60,655.00 TOTAL UNITS A and. B 96 035.00 AND VHREAS, the City Council did thereupon submit all bids received to the Superintendent of Light, Water Power of the City of Anaheim for tabulation and report to the City Council, and said Superintendent of Light, Water Power having tabulated said bids and having submitted his report, the City Council does fina that the sealed -)roposal of AMERICAN PIPE AND CONSTRUCTION CO., P. O. BOX 3428, TERMINAL ANNEX, LOS ANGELES 54, CALIFORNIA, is the lowest responsible bid for the furnishing of reinforced concrete steel cylinder pipe and fittings, including rubber gaskets for installation, as specified in the notice inviting sealed proposals and in accordance with the specifications set forth in said notice inviting sealed proposals, and that said proposal of American Pipe and Construction Co. should be accepted and a contract awarded to said company for furnishing the pipe, fittings and gaskets required by the City of Anaheim. NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Anaheim that said proposal submitted by the American Pipe and Construction Co. for the furnishing of rein- forced concrete cylinder pipe and fittings, including rubber gaskets for installation, as specified in the notice inviting sealed proposals therefor, and in accordance with the specifi- cations set forth in said notice inviting sealed proposals, be, and the same is hereby, accepted, and that a contract for the furnishi of said pipe, fittings and gaskets be, and the same is hereby, awarded to said American Pipe and Construction Co.; and BE IT FURTHER RESOLVED that the award of a contract to said. American Pipe and Construction Co. is declared to be for the approximate quantities set forth in the notice inviting sealed proposals; and BE IT FURTHER RESOLVED that said American Pipe and Construction Co. be, and it is hereby, required to execute a contract for the furnishing of said pipe, fittings and gaskets, in form satisfactory to the City of .Anaheim and upon the terms and conditions specified in the notice inviting sealed pro- posals, the proposal submitted by it, this resolution, and in accordance with the specifications for reinforced concrete steel cylinder pipe and fittings as set forth in said notice inviting sealed proposals, in all required sizes and lengths, at the prices as follow: UNIT A. Item No. 1. Furnishing and delivering 18" I.D. reinforced concrete steel cylinder pipe, including rubber gaskets for installation 6,000' $5.14 per ft. Item No. 2. 18" x 18" x 10" x 6" fabricated cross with 1 18" and 10" and 6" outlets adapted for flanged connection Item No. 3. 18" x 12" x 18" x 10" fabricated cross with 18" outlet opposite 10" outlet and 12" and 10" outlets adapted for flanged con- nection 1 $354.00 ea. 354.00 Item No. 4. 30,840.00 -6- 1 4215.00 ea. 215.00 24" x 12" x 18" x 18" fabri- cated cross with all outlets adapted for flanged connection 1 $429.00 ea. 429.00 Item No. 5. 18" flanged connection to 18" gate valves 4 $86.00 ea. 344.00 Item No. 6. 6" flanged outlets 13 $47.00 ea. 611.00 Item No. 7. 8" flanged outlets 3 856.00 ea.. 168.00 Item No. 8. 1" I.P.S. hub outlets, tapped 75 3.15 ea. 236.25 TOTAL UNIT A $33,197.25 Item No. 1. Furnishing and delivering 16" I.D. reinforced concrete steel cylinder pipe, includ- ing rubber gaskets for instal- lation 11,800' 84.32 per ft. Item No. 2. 16" x 16" x 6" x 6" fabri- cated cross with both 6" outlets adapted for flanged connections Item No. 3. 16" x 16" x 6" x 6" angle cross with both 6" out- lets adapted for flanged connection Item No. 4. 16" x 6" x 16" x 12" fabri- cated cross with 16" outlet opposite 6" outlet and 6" and 12" outlets adapted for flanged connection Item No. 5. UNIT B -7- 850,976.00 1 $179.00 ea. 179.00 1 $179.00 ea. 179.00 1 $285.00 ea. 285.00 16" x 12" x 16" fabricated tee with 16" branch outlet .and 12" outlet adapted for flanged connection 1 S202.00 ea. 202.00 Item No. 6. 16" x 16" x 12" x 12" fabri- cated cross with both 12" outlets and 1 16" outlet adapted for flanged con- nections 3 $296.00 ea. Item No. 7. 16" flanged connections to 16" gate valves 6 78.00 ea. Item No. 8. 6" flanged outlets 33 0 47.00 ea. Item No. 9. 8" flanged outlet 1 56.00 ea. Item No, 10. 1" I.P.S. hub outlets, tapped 175 3.15 ea, Item No. 11. 16", 26 degree elbows 2 $211.00 ea. TOTAL AMOUNT UNITS A and B 888.00 468.00 1,551.00 56.00 551.25 422.00 TOTAL UNIT B $55,757.25 AND BE IT FURTHER RESOLVED by the City Council of the City of Anaheim that said bid be, and the same is hereby, accepted and said contract awarded for the above specified reinforced concrete steel cylinder pipe and fittings, including rubber gaskets for in- stallation, F.O.B. mill or point of shipment, with freight allowed to trenchside, Anaheim, C said pipe, fittings and gaskets to be delivered as follows: The design and layout drawings to be presented within two weeks from receipt of plans and profile, and deliveries of said pipe and fittings to commence sixty-five (65) days after approval of layout drawings, and to be comoleted within twenty- five (25) days thereafter; and BE IT FURTHER RESOLVED that said contract shall contain a provision that should said American Pipe and Construction Co. fail or neglect to furnish said concrete steel cylinder pipe, gaskets and/or fittings in accordance with said specifications and the proposal submitted by it and accepted by the City of Anaheim within the time herein specified, it shall, in addition to any other penalties provided in the contract documents, be liable to the City of Anaheim for all loss or damage that the latter may suffer on account thereof. THE FOREGOING RESOLUTION is signed and approved by me this 26th day of April, 1955. 88,954. MAYOR OF THE CITY OF ANAHEIM. ATTEST: 1 CITY CLERK OF THE CITY OF ANAHEIM STATE OF CALIFORNIA) COUNTY OF ORANGE ss. CITY OF ANAHEIM I, DENE H. WILLIAZS, City Clerk of the City of Anaheim, do hereby certify that the foregoing resolution was introduced and adopted at a regular meeting provided by law of the City Council of the City of Anaheim held on the 26th day of April, 1955, by the following vote: AYES: COUNCILMEN: Pearson, Fry, Schutte, Wisser, and Van Wagoner. NOES: COUNCILMEN: None ABSENT: COUNCILLEN: None AND I FURTHER CERTIFY that the Mayor of the City of Anaheim approved and signed said resolution on the 26th day of April, 1955. IN WITNESS WHEREOF, I have hereunto set my hand and affixed the official seal of the City of Anaheim this 26th day of April, 1955. CITY CLERK OF THE CITY OF AN&HEIM